Siemens HiPath 5000 Service Manual

Siemens HiPath 5000 Service Manual

Hide thumbs Also See for HiPath 5000:
Table of Contents

Advertisement

HiPath 3000 V6.0
HiPath 5000 V6.0
Provisional Service Manual
ESHB.60.004.05.09.22
09/05

Advertisement

Table of Contents
loading

Summary of Contents for Siemens HiPath 5000

  • Page 1 HiPath 3000 V6.0 HiPath 5000 V6.0 Provisional Service Manual ESHB.60.004.05.09.22 09/05...
  • Page 2 An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. The trademarks used are owned by Siemens AG or their respective owners.
  • Page 3: Table Of Contents

    2.3 HiPath 5000 ............2-19 2.4 System-Specific Capacity Limits for HiPath 3000, HiPath 5000 ....2-22 2.5 Static Configuration Rules .
  • Page 4 3.2.4 CBSAP ............3-35 P31003-H3560-S403-54-7620 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 5 3.3.26 TIEL............3-250 3.3.27 TLA2 (Not for U.S.), TLA4 (Not for U.S.), TLA8 (Not for U.S.) ... . 3-265 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0 Provisional Service Manual...
  • Page 6 4.2.2 Installation Procedure ..........4-4 P31003-H3560-S403-54-7620 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 7 4.2.7.1.2 Laying the Line Network and Jumpers on the MDFU-E... . . 4-68 4.2.7.2 Inserting the External Patch Panel S30807K6143-X ....4-72 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0 Provisional Service Manual...
  • Page 8 4.3.4.3.1 Removing the Cabinet Covers ....... 4-131 P31003-H3560-S403-54-7620 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 9 4.4.4.9 Configuration notes ......... . 4-197 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0 Provisional Service Manual...
  • Page 10 6 HiPath 5000 Startup and Administration ........
  • Page 11 6.9 Optimizing Operating System Settings ........6-47 6.10 Perform HiPath 5000 Basic Configuration ....... 6-49 6.10.1 Configuring HiPath 5000 with HiPath ComScendo Service .
  • Page 12: Figure 8-7 Changing Licenses On An Opticlient Attendant V7.0 As Part Of An Upgrade To Hipath

    8.2 Introduction ............8-2 8.3 Licensing for HiPath 3000 V6.0, HiPath 5000 V6.0 ......8-4 8.3.1 Products and Components subject to Mandatory Licensing .
  • Page 13 10.3.3 optiPoint 420 and optiPoint 420 S Telephones ......10-50 10.3.3.1 optiPoint 420 economy, optiPoint 420 economy S ....10-50 P31003-H3560-S403-54-7620, 09/05 0-11 HiPath 3000 V6.0, HiPath 5000 V6.0 Provisional Service Manual...
  • Page 14 11.4 Technical Data for Base Stations ........11-4 P31003-H3560-S403-54-7620 09/05 0-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 15 12.3.1.5 Trace Options for HiPath 3000 ....... . 12-29 12.3.1.6 HiPath Manager PCM Trace Monitor for HiPath 5000 ....12-30 12.3.1.6.1 HiPath Manager PCM Trace Monitor Applications.
  • Page 16 12.5.2 HiPath 5000 Connection Options ........
  • Page 17: Table C-7 Optipoint 400, Optipoint 410, Optipoint 410 S, Optipoint 420, Optipoint 420 S

    C.2 HiPath 5000 ........
  • Page 18 Contents P31003-H3560-S403-54-7620 09/05 0-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 19: Important Information

    Important Information Overview Important Information Overview Provisional Service Manual, HiPath 3000 V6.0, HiPath 5000 V6.0: P31003-H3560-S403-54- 7620, 09/05 (ESHB.60.004.05.09.22) Chapter contents This chapter discusses the topics listed in the following table. Topic Structure of this Electronic Service Manual, page 1-2...
  • Page 20: Structure Of This Electronic Service Manual

    The procedures for the startup of the individual HiPath 3000/5000 components are de- ● scribed in Chapter 5, “Starting Up HiPath 3000”, Chapter 6, “HiPath 5000 Startup and Administration” and Chapter 7, “Starting HiPath 3000 as a Gateway”. Chapter 8, “Licensing” provides information about the HiPath License Management.
  • Page 21: Hipath 3000 V6.0, Hipath 5000 V6.0 , Provisional Service Manual

    Port Numbers Used with HiPath 3000/5000 V6.0”. Appendix D, “Identifying System Power Requirements” provides information about the ● resource requirements of the boards and components of the HiPath 3000 systems. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 22: Electrical Environment

    (ISO 14001). This process ensures that en- ergy consumption and the use of primary raw materials are kept to a mini- mum, thus reducing waste production. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 23: Safety Information

    The following symbols are not generally used in the manual. They explain symbols that may appear on equipment. Electricity Weight Heat Fire Chemicals ESD* Laser * electrostatically sensitive devices P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 24: Safety Information: Dangers

    Use only original accessories or components approved for the system. Failure to observe these instructions may damage the equipment or even violate safety and EMC regulations. System shutdown during maintenance work Procedures to be observed are described in the relevant chapters. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 25: Hipath 3000 V6.0, Hipath 5000 V6.0 , Provisional Service Manual

    Use caution when installing or modifying telephone lines. Never install telephone wiring ● during an electrical storm. Expect leakage current from the telecommunications network. ● When performing work on an open system, ensure that it is never left unsupervised. ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 26: Safety Information: Warnings

    Disconnect all power before working near power supplies unless otherwise instructed by a ● maintenance procedure. Do not attempt to lift objects that you think are too heavy for you. ● Never look directly at a laser beam. ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 27: Safety Information: Cautions

    Always place PC boards on a grounded surface before working on them. ● Only use grounded soldering irons. ● Laying cables Lay cables so as to prevent any risk of them being damaged or causing accidents, such as trip- ping. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 28: General Information

    To ensure the legal fire protection and EMC requirements, operate the HiPath systems only when closed. You may open the system only briefly for assembly and maintenance work. P31003-H3560-S403-54-7620, 09/05 1-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 29: Hipath 3000 V6.0, Hipath 5000 V6.0 , Provisional Service Manual

    European Union and is covered by the directive 2002/96/EC. Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment. P31003-H3560-S403-54-7620, 09/05 1-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 30: What To Do In An Emergency

    Report all accidents, "near accidents", and possible hazards to your manager to ensure ● their causes are resolved as soon as possible. Report any electric shock, no matter how minor. ● P31003-H3560-S403-54-7620, 09/05 1-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 31: Safety Information For Australia (For Australia Only)

    ● ering the system. The mains socket shall be readily accessible. Integrity of the main socket must be assured. HiPath 3000 and HiPath 5000 may only be installed and maintained by authorized service ● personnel. HiPath 3550 and HiPath 3350 must be earthed with a separate bonding earth, if the sys- ●...
  • Page 32: Privacy And Data Security

    Guidelines applicable to Siemens AG employees Employees of Siemens AG are bound to safeguard trade secrets and personal data under the terms of the company’s work rules. In order to ensure that the statutory requirements during service – whether on-site or remote –...
  • Page 33: Information On The Intranet

    Important Information Information on the Intranet Information on the Intranet Up-to-the-minute information on important topics is available on the Siemens intranet. Here is a selection: Table 1-1 Information on the Intranet Contents Languages Product Overview German http://opus1.mchh.siemens.de:8080/ Product descriptions English TopNet/index.html...
  • Page 34 Important Information Information on the Intranet Table 1-1 Information on the Intranet Contents Languages Setting up tracing for the Feature German https://kmoss.icn.siemens.de/livelink/ server English livelink.exe/view/INF-02-000326 Configuration notes and procedures P31003-H3560-S403-54-7620, 09/05 1-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 35: System Data

    HiPath 3500 System Environment – HiPath 3300 System Environment HiPath 5000, page 2-19 System-Specific Capacity Limits for HiPath 3000, HiPath 5000, page 2-22 Static Configuration Rules, page 2-24 Dynamic Configuration Rules, page 2-26 Gateway Channels (DSP Channels), page 2-26 ●...
  • Page 36 Compliance with US and Canadian Standards (For U.S. and Canada Only), page 2-49 ● SAFETY International, page 2-54 ● Environmental Conditions, page 2-55 Electrical Operating Conditions, page 2-55 ● Mechanical Operating Conditions, page 2-55 ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 37: Hipath 3000

    Systems for installation in 19-inch cabinets ● – HiPath 3700 – HiPath 3500 – HiPath 3300 Information on the capacity limits of the different HiPath 3000 systems is provided in Table 2-7. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 38: Design And Dimensions Of The Hipath 3000 Systems

    The cabinets will be delivered accordingly with or without clipped-on connector panels. Two installation options HiPath 3800 is suitable for installation both as a standalone system and in a 19-inch cabinet. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 39: Figure 2-1 Hipath 3800 Dimensions

    System Data HiPath 3000 Dimensions approx. 440 mm approx. 430 mm Figure 2-1 HiPath 3800 Dimensions P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 40: Design And Dimensions Of Hipath 3750

    The UPSM power supply (in all cabinets) and the CPCPR central control board (only in the BC) have fixed positions. Up to two cabinets can be stacked. A main distribution frame unit is needed to complete the communication system. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 41 Depth of the MDFU or MDFU-E: 126 mm Depth of system cabinet: 390 mm approx. approx. 328 mm MDFU MDFU MDFU-E MDFU Cable duct Figure 2-2 HiPath 3750 Dimensions P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 42: Design And Dimensions Of Hipath 3550

    The connection cables to the peripherals (telephones, trunk connections etc.) can be connect- ed directly. Use an external MDFU in certain situations (CMI). Dimensions Mounting sur- 460 mm face 450 mm 200 mm Figure 2-3 HiPath 3550 Dimensions P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 43: Design And Dimensions Of Hipath 3350

    The HiPath 3350 does not need an external main distribution frame. The connection cables to the peripherals (telephones, trunk connections etc.) are directly connected to the boards. Dimensions Mounting sur- 460 mm face 450 mm 128 mm Figure 2-4 HiPath 3350 Dimensions P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 44: Design And Dimensions Of Hipath 3700

    Depth of the system cabinet: approx. 390 mm Necessary height units per cabinet for 19-inch cabinet assembly: 11 (one height unit corresponds to ap- prox. 1.7’’=43 mm) Figure 2-5 HiPath 3700 Dimensions P31003-H3560-S403-54-7620, 09/05 2-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 45: Design And Dimensions Of Hipath 3500

    Dimensions 440 mm 155 mm 380 mm Necessary height units for 19-inch cabinet assembly: 4 (one height unit corresponds to approx. 1.7’’=43 mm) Figure 2-6 HiPath 3500 Dimensions P31003-H3560-S403-54-7620, 09/05 2-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 46: Design And Dimensions Of Hipath 3300

    Dimensions 440 mm 88 mm 380 mm Necessary height units for 19-inch cabinet assembly: 2 (one height unit corresponds to approx. 1.7’’=43 mm) Figure 2-7 HiPath 3300 Dimensions P31003-H3560-S403-54-7620, 09/05 2-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 47: System Environment Of The Hipath 3000 Systems

    STMI2 SLMA LIMS TM2LP SLMA2 LUNA2 TMC16 SLMA8 TMDID SLMO2 MPPI TMEW2 SLMO8 PDMX STMD3 PFT1/PFT4 STMI2 REALS RGMOD for selected countries only used on the STMI2 board P31003-H3560-S403-54-7620, 09/05 2-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 48: Hipath 3750 And Hipath 3700 System Environment

    SLA24N TMS2 TMST1 SLC16N UPSM TMAMF SLMO8 TMCAS SLMO24 GEE8 STMD8 MPPI PDM1 PFT1/PFT4 REAL for Brazil, India, Malaysia, Singapore and ATEA countries only for selected countries only P31003-H3560-S403-54-7620, 09/05 2-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 49: Hipath 3550 System Environment

    8SLA GEE12 EXMNA 16SLA GEE16 GEE50 MPPI OPAL PDM1 STBG4 STRB V24/1 for Brazil, India, Malaysia, Singapore and ATEA countries only for selected countries only For France only P31003-H3560-S403-54-7620, 09/05 2-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 50: Hipath 3350 System Environment

    TLA4 TMQ4 STLSX4 PSUP TLA8 4SLA UPSC-D 8SLA 16SLA ALUM4 ANI4 GEE12 EXMNA GEE16 GEE50 MPPI OPAL PDM1 STBG4 STRB V24/1 for selected countries only For France only P31003-H3560-S403-54-7620, 09/05 2-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 51: Hipath 3500 System Environment

    HXGR3 CBRC HXGR3 IVMS8R STLS4R SLU8R STLSX4R STLS4R CUCR TS2R TMGL4R STLSX4R IMODN TLA4R TST1 8SLAR UPSC-DR ANI4R EXMR MPPI OPALR PDM1 STRBR UAMR for selected countries only P31003-H3560-S403-54-7620, 09/05 2-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 52: Hipath 3300 System Environment

    U.S. HXGR3 CBRC HXGR3 IVMP8R STLS4R IVMS8R STLSX4R SLU8R CUPR TLA4R TMGL4R STLS4R IMODN STLSX4R 8SLAR UPSC-DR ANI4R EXMR MPPI OPALR PDM1 STRBR UAMR for selected countries only P31003-H3560-S403-54-7620, 09/05 2-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 53: Hipath 5000

    M1). HG 1500 in HiPath 3000 and HG3550 V2.0 in HiPath 4000 are prerequisites for IP networking over CorNet IP. Parts of the following setup for HiPath 5000 are optional and can be installed both on the HiPath 5000 Real-Time Services Manager RSM and on a separate PC.
  • Page 54: P31003-H3560-S403

    HiPath FM Desktop V3.0 (Java-based application for error signaling) ● GetAccount (application that prepares generated call data records for further processing.) ● P31003-H3560-S403-54-7620, 09/05 2-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 55 HiPath Cordless Office IP Network optiClient 130 optiClient Attendant V5.0 optiPoint 500 ... optiset E ... PSTN HiPath 3500 HiPath 3750 Figure 2-8 HiPath 5000 RSM Multi-Node IP System P31003-H3560-S403-54-7620, 09/05 2-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 56: System-Specific Capacity Limits For Hipath 3000, Hipath 5000

    – channels and digital network line B channels (S CorNet-IP network trunks 90/128 HG 1500 boards 1 (2 ) 1 (2 – Gateway channels to the system – P31003-H3560-S403-54-7620, 09/05 2-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 57: System-Specific Capacity Limits For Hipath 3000, Hipath 5000

    26 64 HiPath Cordless Office stations at the SLC16N or 32 HiPath Cordless Office stations at the central board. 27 Two HG 1500 boards can be installed if PDM1 is not being used. P31003-H3560-S403-54-7620, 09/05 2-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 58: Static Configuration Rules

    These are special hardware re- sources which facilitate fax via vCA- PI and fax via IP functionality with the T.38 protocol. Teleworker with AES encryption and codec G.711/G.729 (Sampling rate) 20 msec) P31003-H3560-S403-54-7620, 09/05 2-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 59 1 without PDMX PDM1 PDM1 PDM1 PDM1 PDM1 PPP Routing Partner vCAPI clients IP workpoint clients that support vCAPI. MOH data streams PDMX is not currently released. P31003-H3560-S403-54-7620, 09/05 2-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 60: Dynamic Configuration Rules

    Number of Required Gateway Channels (HG 1500 Boards) IP workpoint clients in the system Required number of gateway channels 0 – 3 4 – 12 13 – 16 P31003-H3560-S403-54-7620, 09/05 2-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 61 TDM lines. The required number of HG 1500 boards for VoIP is determined by the sum of the gateway channels, MOH channels and conference channels P31003-H3560-S403-54-7620, 09/05 2-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 62: Moh Channels (G.711, G.723, G.729)

    HG 1500 board. If more than ten MOH data streams are needed simultaneously, MOH should be activated on other HG 1500 boards. HiPath 5000 with HiPath ComScendo Service uses the MOH resources of the gateways logged on, as described above.
  • Page 63: Dmc (Direct Media Connection) Channels

    1 with 2 with- with 1 without PDMX PDM1 PDM1 PDM1 PDM1 PDM1 Sum of PPP channels (for ISDN routing) and gateway channels PDMX is not currently released. P31003-H3560-S403-54-7620, 09/05 2-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 64: Fax / Modem Channels

    T.38. Alternatively, G.711 gateway channels can be used for fax transmis- sion. Note: The number of G.711 gateway channels available is reduced as soon as the DMC inter- working feature is activated with HiPath 3000 Manager E. P31003-H3560-S403-54-7620, 09/05 2-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 65: Determining The Number Of Hg 1500 Boards Required

    0.82 ed H.235 security (in- ent, H.323 client (8 calls per hour) dependent of the IP networking channel (25 calls per hour) WBM setting "En- hanced B Channels") P31003-H3560-S403-54-7620, 09/05 2-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 66 G.729 with packetizing of 3 (60 msec) G.729 with packetizing of 1 (20 msec) G.723 with packetizing of 3 (60 msec) G.723 with packetizing of 1 (30 msec) P31003-H3560-S403-54-7620, 09/05 2-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 67 With AES encryption and 100-byte packet 84 for 100 packets/ length sec. With 3DES encryption and 100-byte packet 93 for 100 packets/ length sec. VCAPI services: Fax channel Data channel P31003-H3560-S403-54-7620, 09/05 2-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 68: Sample Calculation

    HXGM3 board can provide. The configuration is feasible. Note: The configuration is not feasible for HXGS3 and HXGR3 because the static configuration rules only permit up to 16 channels per board. P31003-H3560-S403-54-7620, 09/05 2-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 69: Calculation Example 2: 96 Ip Workpoint Clients And 16 Ip Networking

    WBM.) Total = 461.16 The specified performance requirement of 461.16 points is below the 980 total performance points that the HXGM3 board can provide. The configuration is feasible. P31003-H3560-S403-54-7620, 09/05 2-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 70: Calculation Example 3: 200 Ip Workpoint Clients And Internet Access To Hi

    WBM.) Total = 648.0 The specified performance requirement of 648.0 points is below the 980 total performance points that the HXGM3 board can provide. The configuration is feasible. P31003-H3560-S403-54-7620, 09/05 2-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 71 WBM.) Total = 738.0 The specified performance requirement of 738.0 points is below the 980 total performance points that the HXGM3 board can provide. The configuration is feasible. P31003-H3560-S403-54-7620, 09/05 2-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 72: Calculation Example 4: Ip Networking Connections And Voice Over

    6 x 54.0 = 324.0 Total = 680.8 The specified performance requirement of 680.8 points is below the 980 total performance points that the HXGM3 board can provide. The configuration is feasible. P31003-H3560-S403-54-7620, 09/05 2-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 73: Calculation Example 5: Virtual Private Network Vpn

    The specified performance requirement of 737.6 points is below the 980 total performance points that the HXGM3 board can provide. This configuration is feasible for the central office. P31003-H3560-S403-54-7620, 09/05 2-39 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 74 696.1 The determined resource requirement of 696.1 points is less than the overall performance of 780 points which the HXGR3 board can provide. The branch configuration is feasible. P31003-H3560-S403-54-7620, 09/05 2-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 75: Calculation Example 6: Connecting Teleworkers Via Vpn

    WBM.) Total = 788.72 The specified performance requirement of 788.72 points is below the 980 total performance points that the HXGM3 board can provide. The configuration is feasible. P31003-H3560-S403-54-7620, 09/05 2-41 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 76 354.4 Kbps G.723 with a sample rate of 30 msec Data transfer 512.0 Kbps Total = 866.4 Kbps A 1 Mbps connection would be sufficient for this configuration. P31003-H3560-S403-54-7620, 09/05 2-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 77: Calculation Example 7: Virtual Private Network Vpn With Customer

    IP networking connections. Function Resource require- ment (credit point) Signaling without IP Networking Channel (25 calls per hour) H.235 security (inde- pendent of the WBM setting "Enhanced B Channels") P31003-H3560-S403-54-7620, 09/05 2-43 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 78 240 Kbps G.729 with a sample rate of 20 msec Data transfer 1024 Kbps Total = 1264 Kbps A 2 Mbps connection would be sufficient for this configuration. P31003-H3560-S403-54-7620, 09/05 2-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 79: Notes On The Maintenance Of Gateway Channels Hipath

    MOH Channels can be configured. If 16 B channels are licensed and used exclusively for IP workpoint clients, the 16th B channel must be used as the MOH channel. P31003-H3560-S403-54-7620, 09/05 2-45 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 80: Technical Specifications For Hipath 3000

    (transport weight, in- (not for U.S. and Canada): cluding back- 6.5 kg (14.32 lb.) without ● plane and batteries cabinet feet) 17.5 kg (38.54 lb.) with ● batteries P31003-H3560-S403-54-7620, 09/05 2-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 81: Interface-To-Interface Ranges

    0.6 mm 6.0 dB 1000 m J-2Y(ST)Y 10x2x0.6 ST III BD at 96 kHz A-2Y0F(L)2Y 10x2x0.6 (full PE 0.6 mm 17 dB 350 m insulation, filled) at 1 MHz P31003-H3560-S403-54-7620, 09/05 2-47 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 82: Numbering Plan For Hipath 3000/5000

    – = USA – = USA – = USA – = USA Substitution for “*” Substitution for “#” Service codes *xxx *xxx *xxx *xxx – #xxx #xxx #xxx #xxx P31003-H3560-S403-54-7620, 09/05 2-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 83: Technical Specifications And Compliance To Hipath 3000

    J FCC Part 68 AY3PF05BHIPATH3K8 AY3USA-33046-MF-E AY3USA–25214–MF–E registration AY3USA-33047-KF-E AY3USA–25215–KF–E Industry Cana- 267V-HP3800 267 9147A 267 8782A da CS–03 certi- fication Ringer Equiva- 0.5B lence Number (REN) P31003-H3560-S403-54-7620, 09/05 2-49 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 84: Fcc Compliance

    2.10.2.1.2 FCC Rules, Part 68 Each Siemens system discussed in this section complies with FCC Rules, Part 68. A label on the outside back of the cabinet identifies the FCC registration number, the ringer equivalence number (REN), and other information. If requested, this information must be given to the tele- phone company.
  • Page 85 Nonlive voice equipment such as music-on-hold devices and recorded announcements for sys- tems must be approved by Siemens and registered in accordance with the rules and regula- tions of Subpart C of the FCC Rules, Part 68; or it must be connected through protective cir- cuitry that is approved by Siemens and registered in accordance with the rules and regulations in Subpart C of the FCC Rules, Part 68.
  • Page 86 Customers operating any Siemens system discussed in this section without providing proper answer supervision are in violation of Part 68 of the FCC rules. Each Siemens system discussed in this section returns proper answer supervision to the ● public switched telephone network (PSTN) when DID calls are: –...
  • Page 87: Industry Canada Compliance

    System Data Technical Specifications and Compliance to HiPath 3000 Each Siemens system discussed in this section is capable of providing user access to interstate providers of operator services through the use of equal access codes. Modifications by aggre- gators to alter these capabilities are a violation of the Telephone Operator Consumer Services Improvement Act of 1990 and Part 68 of the FCC Rules.
  • Page 88: Safety International

    Users should not attempt to make such connections themselves, but should contact the electric inspection authority, or electrician, as appropriate. 2.10.3 SAFETY International IEC 60950-1, first edition 2001, modified P31003-H3560-S403-54-7620, 09/05 2-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 89: Environmental Conditions

    Systems covered with condensation must be dried before being used. Do not start up the system until it has thoroughly dried. 2.11.2 Mechanical Operating Conditions The systems are intended for stationary use. P31003-H3560-S403-54-7620, 09/05 2-55 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 90 System Data Environmental Conditions P31003-H3560-S403-54-7620, 09/05 2-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 91: Table 3-1 Hipath 3000 - Functional Overview Of All Boards Used

    HiPath 3000 - Functional Overview of All Boards Used Board Part number Model Central boards CBCC S30810-Q2935-A301 HiPath 3550/HiPath 3350 CBCPR S30810-Q2936-X HiPath 3750/HiPath 3700 CBRC S30810-Q2935-Z301 HiPath 3500/HiPath 3300 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 92 HiPath 3350 RGMOD S30124-X5109-X HiPath 3800 (for selected countries only) UPSC-D S30122-K5660-M300 HiPath 3550/HiPath 3350 UPSC-DR S30122-K7373-M900 HiPath 3500/HiPath 3300 UPSM S30122-K5950-A100 HiPath 3750/HiPath 3700 S30122-K5950-S100 S30122-K5959-S121 (for RSA only) P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 93 HiPath 3800 SLMA2 S30810-Q2246-X HiPath 3800 (for selected countries only) SLMA8 S30810-Q2191-C100 HiPath 3800 SLMO2 S30810-Q2168-X10 HiPath 3800 SLMO8 S30810-Q2168-X100 HiPath 3800 SLMO8 S30810-Q2901-X100 HiPath 3750/HiPath 3700 (not for U.S.) P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 94 HiPath 3550/HiPath 3350 (for U.S. only) TMGL4R S30810-K2918-Z HiPath 3500/HiPath 3300 (for U.S. only) TMGL8 S30810-Q2703-X HiPath 3750/HiPath 3700 (for U.S. only) TML8W S30817-Q626-Axxx/Bxxx HiPath 3750/HiPath 3700 (not for U.S.) P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 95 S30810-K2913-Z300 HiPath 3500 4SLA S30810-Q2923-X200 HiPath 3550/HiPath 3350 (not for U.S.) 8SLA S30810-Q2923-X100 HiPath 3550/HiPath 3350 8SLAR S30810-K2925-Z HiPath 3500/HiPath 3300 16SLA S30810-Q2923-X HiPath 3550/HiPath 3350 (not for U.S.) P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 96 HiPath 3800/HiPath 3750 (not for U.S.) S30777-Q540-X REAL S30807-Q5913-X HiPath 3750/HiPath 3700 REALS S30807-Q6629-X HiPath 3800 STBG4 S30817-Q934-A HiPath 3550/HiPath 3350 (France only) STRB S30817-Q932-A HiPath 3550/HiPath 3350 STRBR S30817-Q932-Z HiPath 3500/HiPath 3300 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 97 HiPath 3000 - Functional Overview of All Boards Used Board Part number Model S30122-X7217-X HiPath 3550/HiPath 3350 (not for U.S.) UAMR S30122-X7402-Z HiPath 3500/HiPath 3300 (not for U.S.) V24/1 S30807-Q6916-X100 HiPath 3550/HiPath 3350 (not for U.S.) P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 98: Table 3-2 Hipath 3000 - Overview Of All Boards Models Used

    Peripheral board (not for U.S.) SLMA S30810-Q2191-C300 Peripheral board SLMA2 S30810-Q2246-X Peripheral board (for selected countries only) SLMA8 S30810-Q2191-C100 Peripheral board SLMO2 S30810-Q2168-X10 Peripheral board SLMO8 S30810-Q2168-X100 Peripheral board STMD3 S30810-Q2217-X10 Peripheral board P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 99 Part number Function STMI2 S30810-Q2316-X100 Peripheral board TM2LP S30810-Q2159-Xxxx Peripheral board TMC16 S30810-Q2485-X Peripheral board (for selected countries only) TMDID S30810-Q2452-X Peripheral board (for U.S. only) TMEW2 S30810-Q2292-X100 Peripheral board P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 100 TMGL8 S30810-Q2703-X Peripheral board (for U.S. only) TML8W S30817-Q626-Axxx/Bxxx Peripheral board (not for U.S.) TMST1 S30810-Q2920-X Peripheral board (for U.S. only) TMS2 S30810-Q2915-X Peripheral board (not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 101 Boards for HiPath 3000 Overview Table 3-2 HiPath 3000 - Overview of All Boards Models Used Board Part number Function UPSM S30122-K5950-A100 Central board S30122-K5950-S100 S30122-K5959-S121 (for RSA only) P31003-H3560-S403-54-7620, 09/05 3-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 102: Boards For Hipath 3000

    Peripheral board (not for U.S.) SLA16N S30810-Q2929-X100 Peripheral board SLA24N S30810-Q2929-X Peripheral board SLC16N S30810-Q2193-X100 Peripheral board (not for U.S.) SLMO24 S30810-Q2901-X Peripheral board SLU8 S30817-Q922-A301 Peripheral board P31003-H3560-S403-54-7620, 09/05 3-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 103 UPSC-D S30122-K5660-M300 Central board V24/1 S30807-Q6916-X100 Option (not for U.S.) 4SLA S30810-Q2923-X200 Peripheral board (not for U.S.) 8SLA S30810-Q2923-X100 Peripheral board 16SLA S30810-Q2923-X Peripheral board (not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 104 Cable PDM1 S30807-Q5692-X100 Option PSUP S30122-K5658-M Central board SLU8 S30817-Q922-A301 Peripheral board STBG4 S30817-Q934-A Option (France only) STLS2 S30817-Q924-B313 Peripheral board (not for U.S.) STLS4 S30817-Q924-A313 Peripheral board P31003-H3560-S403-54-7620, 09/05 3-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 105 UPSC-D S30122-K5660-M300 Central board V24/1 S30807-Q6916-X100 Option (not for U.S.) 4SLA S30810-Q2923-X200 Peripheral board (not for U.S.) 8SLA S30810-Q2923-X100 Peripheral board 16SLA S30810-Q2923-X Peripheral board (not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 106 TST1 S30810-K2919-Z Peripheral board (for U.S. only) TS2R S30810-K2913-Z300 Peripheral board (not for U.S.) UAMR S30122-X7402-Z Option (not for U.S.) UPSC-DR S30122-K7373-M900 Central board 8SLAR S30810-K2925-Z Peripheral board P31003-H3560-S403-54-7620, 09/05 3-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 107 TLA4R S30817-Q923-Zxxx Peripheral board (not for U.S.) TMGL4R S30810-K2918-Z Peripheral board (for U.S. only) UAMR S30122-X7402-Z Option (not for U.S.) UPSC-DR S30122-K7373-M900 Central board 8SLAR S30810-K2925-Z Peripheral board P31003-H3560-S403-54-7620, 09/05 3-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 108: Central Boards

    For Australia only: The T/R interfaces supply a ring voltage of 35 V . Depending on the terminals connected, we cannot exclude the possibility of errors occurring during ringing state. P31003-H3560-S403-54-7620, 09/05 3-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 109 0.5 s on/0.5 s off Flashing MMC removed or defective 0.1 s on/0.1 s off The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm. P31003-H3560-S403-54-7620, 09/05 3-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 110 Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for > testing (module test at the factory). Disconnection does not necessarily delete the customer database (CDB). To delete the CDB, use the reset switch. P31003-H3560-S403-54-7620, 09/05 3-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 111: Table 3-5 Cbcc - S Interface Assignment (Rj45 Jacks)

    1, receive + port 2, receive + port 1, receive – port 2, receive – port 1, transmit – port 2, transmit – – – – – P31003-H3560-S403-54-7620, 09/05 3-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 112: Table 3-6 Cbcc - V.24 Interface Assignment (Sub-D Plug)

    Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 113 P0/E (slave) P0/E P0/E P0/E P0/E P0/E P0/E P0/E T/R 1 T/R 2 T/R 3 T/R 3 EVM-1 EVM-2 Line Code Port 7801 CO PP 7802 7803 7804 P31003-H3560-S403-54-7620, 09/05 3-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 114 P0/E P0/E client P0/E P0/E (slave) P0/E P0/E P0/E P0/E P0/E P0/E P0/E T/R 1 T/R 2 T/R 3 T/R 3 EVM-1 EVM-2 Line Code Port CO PP P31003-H3560-S403-54-7620, 09/05 3-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 115: Cbrc

    Backplane (CUCR or CUPR) connection via slots 1 (X11), 2 (X5) and 3 (X6) ● Music on hold: MPPI, EXMR ● Options bus (O bus) ● V.24 interface ● P31003-H3560-S403-54-7620, 09/05 3-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 116 0.5 s on/0.5 s off Flashing MMC removed or defective 0.1 s on/0.1 s off The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm. P31003-H3560-S403-54-7620, 09/05 3-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 117: Figure 3-2 Cbrc Board (S30810-Q2935-Z301)

    Disconnecting the battery buffer by unplugging the X27 jumper is necessary only for > testing (module test at the factory). Disconnection does not necessarily delete the customer database (CDB). To delete the CDB, use the reset switch. P31003-H3560-S403-54-7620, 09/05 3-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 118: Table 3-12 Cbrc - S Interface Assignment (Rj45 Jacks)

    1, receive + port 2, receive + port 1, receive – port 2, receive – port 1, transmit – port 2, transmit – – – – – P31003-H3560-S403-54-7620, 09/05 3-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 119: Table 3-13 Cbrc - V.24 Interface Assignment (Sub-D Plug)

    Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 120 P0/E (slave) P0/E P0/E P0/E P0/E P0/E P0/E P0/E T/R 1 T/R 2 T/R 3 T/R 3 EVM-1 EVM-2 Line Code Port 7801 CO PP 7802 7803 7804 P31003-H3560-S403-54-7620, 09/05 3-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 121 P0/E P0/E client P0/E P0/E (slave) P0/E P0/E P0/E P0/E P0/E P0/E P0/E T/R 1 T/R 2 T/R 3 T/R 3 EVM-1 EVM-2 Line Code Port CO PP P31003-H3560-S403-54-7620, 09/05 3-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 122: Cbcpr

    Switch pressed > 5 s = Reload activated (RUN LED out indicates that a reload is in progress) RUN LED ● Signals the current status of the CBCPR board (see Table 12-2). P31003-H3560-S403-54-7620, 09/05 3-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 123 Diagram of the CBCPR board Reset/reload switch RUN LED Batt. LAN connector, IMODN 8-pin RJ45 jack V.24 interface, 9-pin SUB-D plug (service PC or application) MPPI Figure 3-3 CBCPR Board (S30810-Q2936-X) P31003-H3560-S403-54-7620, 09/05 3-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 124: Table 3-17 Cbcpr - V.24 Interface Assignment (Sub-D Plug)

    Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 125: Cbsap

    Two LEDs indicating the board status: ● – Run (green) = signals the current status of the CBSAP board (see Table 12-2) – Fail (red) = error encountered P31003-H3560-S403-54-7620, 09/05 3-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 126: Figure 3-4 Cbsap Board (S30810-Q2314-X)

    – Flashing = active – LED2 (green): – On = full-duplex (FDX) – Off = half-duplex Diagram of CBSAP board IMODN LIMS MPPI Figure 3-4 CBSAP Board (S30810-Q2314-X) P31003-H3560-S403-54-7620, 09/05 3-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 127: Figure 3-5 Cbsap - Front Panel

    Yellow = 10 Mbps online (link) – Flashing = active LED2 (green): ● – On = full-duplex (FDX) – Off = half-duplex Figure 3-5 CBSAP - Front Panel P31003-H3560-S403-54-7620, 09/05 3-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 128: Table 3-19 Cbsap - V.24 Interface Assignment (Sub-D Plug)

    Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 129: Cma

    The CMA module is needed for special HiPath Cordless Office configurations. All clock module small (CMS) functions are available when you insert a CMA module. Please refer to Page 3-40 for recommendations on CMA module implementation. P31003-H3560-S403-54-7620, 09/05 3-39 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 130: Cms

    ISDN S ISDN S ● ● Master Slave System System(s) Ethernet/IP ● (10/100 HiPath 3000 HiPath 3000 BaseT) System 1 System(s) Figure 3-7 Networking Options for HiPath 3000 Systems P31003-H3560-S403-54-7620, 09/05 3-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 131 (always ISDN S (always ISDN S active) trunk con- active) trunk con- nection nection ISDN ISDN S – ISDN S ISDN S trunk con- trunk con- nection nection P31003-H3560-S403-54-7620, 09/05 3-41 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 132 (always ISDN S (always ISDN S active) trunk con- active) trunk con- nection nection ISDN ISDN S – ISDN S ISDN S trunk con- trunk con- nection nection P31003-H3560-S403-54-7620, 09/05 3-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 133 The more accurate the clock source in the relevant systems, the fewer the faults. P31003-H3560-S403-54-7620, 09/05 3-43 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 134: Cr8N

    Over 24 ports: Two CR8N boards required. ● These are general recommendations only. In some cases, a CR8N board may already be re- quired for six ports under extreme load conditions. P31003-H3560-S403-54-7620, 09/05 3-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 135: Figure 3-8 Cr8N (S30810-Q2513-X100)

    Board is faulty. Flashing Loadware is being loaded. Board test unsuccessful, board is defective. Replace board. Board test completed successfully. Board is OK (temporary transition). Flashing Board operational. P31003-H3560-S403-54-7620, 09/05 3-45 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 136: Cuc And Cucr

    Slot 6 (X40) Slot 7 (X50) CUCR Peripheral board Slot 8 (X60) Slot 9 (X70) Peripheral board Slot 4 (X20) PSU/UPS (X1) Slot 5 (X30) Figure 3-10 CUCR Backplane (S30777-Q750-Z) P31003-H3560-S403-54-7620, 09/05 3-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 137: Cup And Cupr

    Slot 3 (8 x U (2 x S (4 x T/R) P0/E Peripheral board Slot 4 (X20) PSU/UPS (X1) Slot 5 (X30) CUPR Figure 3-12 CUPR Backplane (S30777-Q751-Z) P31003-H3560-S403-54-7620, 09/05 3-47 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 138: Dbsap

    The cable (C39195-Z7611-A10) is used as the connection cable between basic cab- > inet (X201 jack) and expansion cabinet (DBSAP board). To ensure smooth opera- tion, use only shielded cables with a maximum length of 1 m. P31003-H3560-S403-54-7620, 09/05 3-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 139: Figure 3-14 Dbsap On The Backplane Of The Expansion Cabinet

    Boards for HiPath 3000 Central Boards DBSAP Figure 3-14 DBSAP on the Backplane of the Expansion Cabinet P31003-H3560-S403-54-7620, 09/05 3-49 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 140: Imodn

    If the IMODN loadware is not updated when the system is reset, the green LED starts to flash approx. 10 seconds after the reset. The green LED continues to flash after the system boot. P31003-H3560-S403-54-7620, 09/05 3-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 141: Lim

    Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-51 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 142: Figure 3-15 Lim In Hipath 3750 And Hipath 3700 - Procedure For Lan

    60 mm Figure 3-15 LIM in HiPath 3750 and HiPath 3700 - Procedure for LAN Connection Figure 3-16 LIM in HiPath 3750 and HiPath 3700 - Adapter Cable (C39195-Z7213-A1) P31003-H3560-S403-54-7620, 09/05 3-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 143: Figure 3-17 Lim In Hipath 3750 And Hipath 3700 - Attachment Of The Patch Cable

    Boards for HiPath 3000 Central Boards Figure 3-17 LIM in HiPath 3750 and HiPath 3700 - Attachment of the Patch Cable to the Backplane Grill P31003-H3560-S403-54-7620, 09/05 3-53 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 144: Lims

    TAPI ports. The use of "power dialers" is not approved. You cannot operate the LIMS module and an STMI2 board simultaneously in a HiPath 3800. Figure 3-18 CBSAP with LIMS Module Plugged In P31003-H3560-S403-54-7620, 09/05 3-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 145 Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-55 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 146: Luna2

    Battery cable for BSG 48/38: S39195-A7985-B10 (A battery cable is required for each system cabinet to be connected.) – Battery 12 V/38 Ah: S30122-X5950-F320 (Four batteries necessary for each BSG 48/38.) P31003-H3560-S403-54-7620, 09/05 3-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 147 Measurement conditions: All measurements were performed at a room temperature of approximately 22 °C ● (71.6 °F). The batteries were new and fully charged when measurement started. ● P31003-H3560-S403-54-7620, 09/05 3-57 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 148: Figure 3-19 Luna2 Front Panel

    LUNA2 may not be sufficient (an additional LUNA2 module is required. For information on how to calculate the number of LUNA2 modules required, see Page 3-62). b) LUNA2 may be defective (the board must be replaced). P31003-H3560-S403-54-7620, 09/05 3-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 149 LUNA2 redundancy should be plugged in (set to mode 1). – are used as a battery charger should be plugged in (set to mode 2a or mode 2b). P31003-H3560-S403-54-7620, 09/05 3-59 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 150: Figure 3-20 Luna2 Slots In The Basic Cabinet (With Outer Panel Mounted)

    The power supply unit slots must be covered with the outer panel shown in Figure 3-20 (basic cabinet) and in Figure 3-21 (expansion cabinet) before the system is started up. Figure 3-20 LUNA2 Slots in the Basic Cabinet (With Outer Panel Mounted) P31003-H3560-S403-54-7620, 09/05 3-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 151: Figure 3-21 Luna2 Slots In The Expansion Cabinet (With Outer Panel Mounted)

    Boards for HiPath 3000 Central Boards Figure 3-21 LUNA2 Slots in the Expansion Cabinet (With Outer Panel Mounted) P31003-H3560-S403-54-7620, 09/05 3-61 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 152: Table 3-26 Determining The Number Of Luna2 Modules Required Per Cabinet

    Two LUNA2s are always required to supply a CBSAP, peripheral boards and ● PBXXX, STMI2, SLMA and/or SLCN. A third LUNA2 can be used as a battery charger or as a redundant LUNA2. ● P31003-H3560-S403-54-7620, 09/05 3-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 153: Figure 3-22 Rear View Of The Bsg 48/38 Battery Cabinet (S30122-K5950-F300)

    + – outputs BSG 48/38 DC output 1: –48 V to HiPath 3800 AC input 230 V Figure 3-22 Rear View of the BSG 48/38 Battery Cabinet (S30122-K5950-F300) P31003-H3560-S403-54-7620, 09/05 3-63 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 154: Figure 3-23 Connections Between The Bsg 48/38 Battery Cabinet And

    AC power Note: For reasons of clarity, the system cabinets are shown sepa- rately and without grounding. Figure 3-23 Connections Between the BSG 48/38 Battery Cabinet and HiPath 3800 P31003-H3560-S403-54-7620, 09/05 3-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 155: Mmc

    CDB backup and the relevant version-specific application processor software (APS). Please note that the MMC may only be replaced by a multimedia card approved by Siemens AG. Cards that have not been approved may have a different internal structure which can affect temporal access and certain features (for example, CDB backup and APS transfer).
  • Page 156 HiPath 3000 Version 6.0 MMC64 S30122-X8002-X10 Welt X X X X X X X (64 MB) (= leere Basis-MMC) P30152-P1205-P2 P30152-P1205-P1 X X X X X X P31003-H3560-S403-54-7620, 09/05 3-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 157: Psup

    20 Hz 25 Hz = Germany + international ● 50 Hz = France ● To CUP 20 Hz = U.S. ● Power plug Figure 3-24 PSUP Interface (S30122-K5658-M) P31003-H3560-S403-54-7620, 09/05 3-67 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 158: Rgmod (For Selected Countries Only)

    Standard 75 V 25 Hz European standard 65 V 25 Hz Switzerland Table 3-28 RGMOD (for selected countries only) - Setting the Ring Voltages and Ring Fre- quencies P31003-H3560-S403-54-7620, 09/05 3-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 159 Setting Standard 75 V 50 Hz France 85 V 20 Hz U.S. Table 3-28 RGMOD (for selected countries only) - Setting the Ring Voltages and Ring Fre- quencies P31003-H3560-S403-54-7620, 09/05 3-69 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 160 10-pin port X214 of the basic cabinet (see Figure 3-25). X214 Figure 3-25 HiPath 3800 - Connectors and Jacks on the Backplane of the Basic Cabi- P31003-H3560-S403-54-7620, 09/05 3-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 161 10-pin port X214 of the expansion cabinet (see Figure 3-26). X214 Figure 3-26 HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion Cabinet P31003-H3560-S403-54-7620, 09/05 3-71 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 162: Upsc-D

    This is the only battery pack released for connection to UPSC-D. Danger Do not use 24-V batteries (S30122-K5403-X) in conjunction with UPSC-D as an ex- plosive gas (hydrogen + oxygen) escapes when the battery is overloaded. P31003-H3560-S403-54-7620, 09/05 3-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 163 4 VA Measurement conditions: All measurements were performed at a room temperature of approximately 23 °C ● (73.4°F). The batteries were fully charged when the measurement was started. ● P31003-H3560-S403-54-7620, 09/05 3-73 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 164: Figure 3-27 Upsc-D (S30122-K5660-M300)

    (battery pack): up = off, battery voltage deactivated ● LED, yellow (battery backup off) CUC/ down = on, battery voltage activated ● (battery backup on) Figure 3-28 UPSC-D (S30122-K5660-M300) P31003-H3560-S403-54-7620, 09/05 3-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 165: Figure 3-29 Upsc-D - Switches And Leds

    (battery pack) LED, green: +5-V output voltage is available Slide switch for setting the ring fre- quency Figure 3-29 UPSC-D - Switches and LEDs P31003-H3560-S403-54-7620, 09/05 3-75 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 166: Figure 3-30 Upsc-D - Connectors

    Boards for HiPath 3000 Central Boards Connectors Connector for battery pack Connector for EPSU2 Power plug Figure 3-30 UPSC-D - Connectors P31003-H3560-S403-54-7620, 09/05 3-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 167: Upsc-Dr

    To do this, connect the DC port on the EPSU2-R to the special –48-Vdc input on the UPSC-DR. The UPSC-DR’s internal -48 V output is deactivated when the external power supply is connected. P31003-H3560-S403-54-7620, 09/05 3-77 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 168 HiPath 3500 UPSC-DR with Normal output load 60 % = 5 V: 4.8 A; 2h 40min EPSU2-R –48 V: 1.8 A (external via EPSU2-R); ringing approx. 2 VA P31003-H3560-S403-54-7620, 09/05 3-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 169 All measurements were performed at a room temperature of approximately 23 °C ● (73.4 °F). The batteries were fully charged when the measurement was started. ● Diagram of UPSC-DR LED, green LED, yellow Figure 3-31 UPSC-DR (S30122-K7373-M900) P31003-H3560-S403-54-7620, 09/05 3-79 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 170 EPSU2-R (installed Batt –48 V from EPSU2-R in the ECR) +48 V from EPSU2-R AC outlet 19-inch housing for HiPath 3500 and HiPath 3300 Figure 3-32 UPSC-DR (S30122-K7373-M900) P31003-H3560-S403-54-7620, 09/05 3-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 171: Figure 3-33 Upsc-Dr - Switches And Leds

    (batter- ies) LED, green: +5-V output voltage is available Slide switch for setting the ring fre- quency Figure 3-33 UPSC-DR - Switches and LEDs P31003-H3560-S403-54-7620, 09/05 3-81 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 172: Figure 3-34 Upsc-Dr - Connectors

    Boards for HiPath 3000 Central Boards Connectors Connector for batteries and Power plug EPSU2-R (installed in the ECR) Figure 3-34 UPSC-DR - Connectors P31003-H3560-S403-54-7620, 09/05 3-82 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 173: Upsm

    The only exception is the UPSM model S30122-K5950-S121 which supplies a ring voltage of 60 V and is only implemented in the Republic of South Africa (RSA). P31003-H3560-S403-54-7620, 09/05 3-83 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 174 Battery cable for BSG 48/38: S30122-X5950-F310 (One battery cable is required for each system cabinet (UPSM) to be connected.) – Battery 12 V/38 Ah: S30122-X5950-F320 (Four batteries necessary for each BSG 48/38.) P31003-H3560-S403-54-7620, 09/05 3-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 175 UPSM model for RSA) ● Output frequencies: 20/25/50 Hz ● Output power ● – continuous: 4.0 VA – peak: 8.0 VA temporary (3 min. load/15 min. break) P31003-H3560-S403-54-7620, 09/05 3-85 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 176: Figure 3-35 Front And Rear Views Of The Upsm (S30122-K5950-S100)

    1) Contact (max. 100 mA) closes when battery mode is ac- tivated. A relay connected in series can be used for signaling purposes, for example. Figure 3-35 Front and Rear Views of the UPSM (S30122-K5950-S100) P31003-H3560-S403-54-7620, 09/05 3-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 177 20 Hz Off On Off 25 Hz Off Off On 50 Hz (S4 = used for factory testing) Figure 3-36 Front and Rear Views of the UPSM (S30122-K5950-A100) P31003-H3560-S403-54-7620, 09/05 3-87 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 178: Figure 3-37 Rear View Of The Bsg 48/38 Battery Cabinet (S30122-K5950-F300)

    BSG 48/38 DC output 1: –48 V to HiPath 3750 and HiPath 3700 AC input 230 V Figure 3-37 Rear View of the BSG 48/38 Battery Cabinet (S30122-K5950-F300) P31003-H3560-S403-54-7620, 09/05 3-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 179: Figure 3-38 Connections Between The Bsg 48/38 Battery Cabinet And Upsm (Hipath 3750, Hipath 3700)

    Contact (max. 100 mA) closes when battery mode is activated. A relay con- nected in series can be used for signaling purposes, for example. Figure 3-38 Connections between the BSG 48/38 Battery Cabinet and UPSM (HiPath 3750, HiPath 3700) P31003-H3560-S403-54-7620, 09/05 3-89 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 180: Peripheral Boards

    Installation of the cPCI box CSAPE in the system is a purely mechanical operation. There is no electrical connection between the system and the cPCI box CSAPE All communication be- tween HiPath 3800 and HiPath All-in-One takes place over the IP network. P31003-H3560-S403-54-7620, 09/05 3-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 181 Boards for HiPath 3000 Peripheral Boards Front panel Fan drawer AC power supply unit ACPCI Slide-in shelves for the Embed- ded Application Server EAS Fan drawer Figure 3-39 CSAPE (S30807-U6630-X) P31003-H3560-S403-54-7620, 09/05 3-91 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 182: Figure 3-40 Hipath 3800 - Board Slots In The Basic Cabinet

    Figure 3-40 shows the slot for the cPCI box CSAPE in the basic cabinet. Please refer to Special board attachments for installation information. Figure 3-40 HiPath 3800 - Board Slots in the Basic Cabinet P31003-H3560-S403-54-7620, 09/05 3-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 183: Diu2U (For U.s. Only)

    DIU2U Adapter Cable C39195-A7269-B625 (for U.S. only) Table 3-32 DIU2U (for U.S. only) - adapter cable assignment (C39195-A7269-B625) 15-pin Sub-D 50-pin Amphenol Function Color code connector connector a-wire (T), transmit wht/blu P31003-H3560-S403-54-7620, 09/05 3-93 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 184 Front panel Two LEDs indicating the board status: LED (green) ● LED (red) ● Interface 1 Interface 2 Figure 3-42 DIU2U (for U.S. only) - Front Panel (S30810-Q2216-X) P31003-H3560-S403-54-7620, 09/05 3-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 185: Table 3-33 Diu2U (For U.s. Only) - Led Statuses

    HiPath 3000 Manager E. not, replace board. Flashing Loadware is being loaded. Board test completed successfully. Board is OK (idle state). Flashing At least one channel is activated. P31003-H3560-S403-54-7620, 09/05 3-95 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 186: Diun2

    ● In HiPath 3000/5000 V5.0 and later, the B channels in the DIUN2 board are subject > to license. Information on licensing can be found in Chapter 8. P31003-H3560-S403-54-7620, 09/05 3-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 187 Boards for HiPath 3000 Peripheral Boards Front panel Two LEDs indicating the board status: LED (green) ● LED (red) ● Interface 1 Interface 2 Figure 3-43 DIUN2 - Front Panel (S30810-Q2196-X) P31003-H3560-S403-54-7620, 09/05 3-97 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 188 15-pin Sub-D jacks on the front panel. Copper cable ● The copper cable is only connected via the 15-pin Sub-D jacks on the front panel. P31003-H3560-S403-54-7620, 09/05 3-98 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 189 Table 3-36 DIUN2 - Assigning the System Cable S30267-Z167-Axxx Function Color code a-wire (T), transmit ora/wht b-wire (R), transmit wht/ora a-wire (T), receive blu/wht b-wire (R), receive wht/blu P31003-H3560-S403-54-7620, 09/05 3-99 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 190: Hxgm3

    HXGM3 Board Versions Board Part number Services DSPs B channels DSP channels HXGM3 S30810-Q2942-X Voice and Data Eight simultaneous Voice over IP connections are possible per DSP (Digital Signal Processor). P31003-H3560-S403-54-7620, 09/05 3-100 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 191 Up to two PDM1 modules ● (PMC DSP modules) Q5692-X100 for an additional eight per HXGM3. DSP channels. Installed at HGA slots 0 ● and 2 only. Figure 3-44 HXGM3 (S30810-Q2942-X) P31003-H3560-S403-54-7620, 09/05 3-101 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 192: Figure 3-45 Hxgm3 - Interfaces

    LAN connections HGA slot 0 HGA slot 1 via LAN adapter connector: LAN 2 (SU Xx8) V.24 interface X10 LAN 1 (SU Xx9) Figure 3-45 HXGM3 - Interfaces P31003-H3560-S403-54-7620, 09/05 3-102 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 193 HXGM3 - Assignment of V.24 Interface X10 Signal Remark Internal pull-up resistor in level switch (MAX211E) Ground Internal pull-up resistor in level switch (MAX211E) Internal pull-up resistor in level switch (MAX211E) P31003-H3560-S403-54-7620, 09/05 3-103 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 194 Signals TT1/2 and RT1/2 are not needed for transmitting data. They represent a signal termi- nation of 100 ohms (so-called Bob Smith termination) for the two unused wire pairs in a 4-pair twisted pair cable. P31003-H3560-S403-54-7620, 09/05 3-104 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 195 TT1 (Transmit Termination 1) TT2 (Transmit Termination 2) RDP (Receive Data +) RDN (Receive Data –) RT1 (Receive Termination 1) RT2 (Receive Termination 2) 25, 50 Housing Shield P31003-H3560-S403-54-7620, 09/05 3-105 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 196: Hxgs3, Hxgr3

    5, 7, 9 in HiPath 3550 and slot 5 in HiPath 3350). For information on how to calculate the number of boards required for HG 1500, see Section 2.6.8. P31003-H3560-S403-54-7620, 09/05 3-106 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 197: Table 3-43 Hxgs3/Hxgr3 Board Versions

    Part number Function Notes module PDM1 S30807-Q5692- Used for expansion for an addi- Maximum of one (PMC DSP X100 tional eight DSP channels. PDM1 module possi- modules) ble. P31003-H3560-S403-54-7620, 09/05 3-107 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 198: Figure 3-48 Hxgs3 (S30810-Q2943-X)

    Boards for HiPath 3000 Peripheral Boards Figure 3-48 HXGS3 (S30810-Q2943-X) Figure 3-49 HXGR3 (S30810-K2943-Z) P31003-H3560-S403-54-7620, 09/05 3-108 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 199: Figure 3-50 Hxgs3/Hxgr3 - Interfaces

    ● LAN connectors: LAN 1 (X2) HGA slot 1 HGA slot 0 LAN 2 (X3) CUC/ CUCR or CUP/ CUPR V.24 interface X4 Figure 3-50 HXGS3/HXGR3 - Interfaces P31003-H3560-S403-54-7620, 09/05 3-109 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 200: Table 3-45 Hxgs3/Hxgr3 - Lan Interface Assignment

    Signals TT1/2 and RT1/2 are not needed for transmitting data. They represent a signal termi- nation of 100 ohms (so-called Bob Smith termination) for the two unused wire pairs in a 4-pair twisted pair cable. P31003-H3560-S403-54-7620, 09/05 3-110 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 201 HXGS3/HXGR3 - Assignment of V.24 Interface X10 Signal Remark Internal pull-up resistor in level switch (MAX211E) Ground Internal pull-up resistor in level switch (MAX211E) Internal pull-up resistor in level switch (MAX211E) P31003-H3560-S403-54-7620, 09/05 3-111 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 202 Grasp the housing cover by its outside walls only. Start the system by plugging in the power plug. In the case of an uninterruptible power supply, the battery must then be switched on. P31003-H3560-S403-54-7620, 09/05 3-112 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 203 Boards for HiPath 3000 Peripheral Boards Figure 3-51 HXGS3 - Installation of the Fan Kit in HiPath 3550 P31003-H3560-S403-54-7620, 09/05 3-113 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 204: Figure 3-52 Hxgs3 - Securing Clips For Fan Kit

    Boards for HiPath 3000 Peripheral Boards Figure 3-52 HXGS3 - Securing Clips for Fan Kit Figure 3-53 HXGS3 - Connection of the Fan Kit P31003-H3560-S403-54-7620, 09/05 3-114 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 205: Ivml8, Ivml24

    HiPath Xpressions Compact supports a central voice mail functionality in a HiPath > 3000/5000 network. All stations can use the central voice mail server. HiPath Xpressions Compact cannot be used as a central announcement device in a network. P31003-H3560-S403-54-7620, 09/05 3-115 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 206: Figure 3-54 Ivml8 And Ivml24 - Packing Protection Covering

    If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering. Figure 3-54 IVML8 and IVML24 - Packing Protection Covering P31003-H3560-S403-54-7620, 09/05 3-116 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 207 To reset the board to the default state, activate the lockout switch twice within the first 10 s of board startup. P31003-H3560-S403-54-7620, 09/05 3-117 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 208 Lockout switch activated during a call (500/ (500/ 500 ms) 500 ms) Board locked or board error occurred Check whether board was deactivated using HiPath 3000 Manager E or lockout switch. P31003-H3560-S403-54-7620, 09/05 3-118 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 209 TT1 (Transmit Termination 1) TT2 (Transmit Termination 2) RDP (Receive Data +) RDN (Receive Data –) RT1 (Receive Termination 1) RT2 (Receive Termination 2) Not used in 4-wire cable P31003-H3560-S403-54-7620, 09/05 3-119 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 210: Ivmnl, Ivmn8

    Only one IVMNL or IVMN8 may be installed per HiPath 3800 system. > Caution For thermal reasons the IVMNL board may only be installed in the basic cabinet. P31003-H3560-S403-54-7620, 09/05 3-120 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 211: Figure 3-57 Ivmnl/Ivmn8 - Packing Protection Covering

    If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering. Figure 3-57 IVMNL/IVMN8 - Packing Protection Covering P31003-H3560-S403-54-7620, 09/05 3-121 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 212: Figure 3-58 Ivmnl/Ivmn8 - Front Panel (S30122-H7688-X -X100)

    Two LEDs indicating the board status: LED (green) ● LED (yellow) ● Lockout switch Ethernet (10/100BaseT) interface (8-pin RJ45 jack) Figure 3-58 IVMNL/IVMN8 - Front Panel (S30122-H7688-X -X100) P31003-H3560-S403-54-7620, 09/05 3-122 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 213 Check whether board was deacti- curred vated using HiPath 3000 Manag- er E or lockout switch. During Operation Idle (no call) Flashing At least one active port (call) (500/ 500 ms) P31003-H3560-S403-54-7620, 09/05 3-123 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 214 Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-124 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 215: Ivmp8 (Not For U.s.), Ivmp8R (Not For U.s)

    HiPath Xpressions Compact supports a central voice mail functionality in a HiPath > 3000/5000 network. All stations can use the central voice mail server. HiPath Xpressions Compact cannot be used as a central announcement device in a network. P31003-H3560-S403-54-7620, 09/05 3-125 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 216: Figure 3-59 Ivmp8 And Ivmp8R (Not For U.s.) - Packing Protection Covering

    If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering. Figure 3-59 IVMP8 and IVMP8R (not for U.S.) - Packing Protection Covering P31003-H3560-S403-54-7620, 09/05 3-126 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 217: Figure 3-60 Ivmp8, Ivmp8R (S30122-Q7379-X100, -K7379-Z100)

    To reset the board to the default state, activate the lockout switch twice within the first 10 s of board startup. P31003-H3560-S403-54-7620, 09/05 3-127 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 218 Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-128 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 219 Lockout switch activated during a call (500/ (500/ 500 ms) 500 ms) Board locked or board error occurred Check whether board was de- activated using HiPath 3000 Manager E or lockout switch. P31003-H3560-S403-54-7620, 09/05 3-129 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 220: Ivms8, Ivms8R

    HiPath Xpressions Compact supports a central voice mail functionality in a HiPath > 3000/5000 network. All stations can use the central voice mail server. HiPath Xpressions Compact cannot be used as a central announcement device in a network. P31003-H3560-S403-54-7620, 09/05 3-130 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 221: Figure 3-61 Ivms8 And Ivms8R - Packing Protection Covering

    If it is necessary to transport the board again at a later time, for example, for servicing, you must reattach the packing protection covering. Figure 3-61 IVMS8 and IVMS8R - Packing Protection Covering P31003-H3560-S403-54-7620, 09/05 3-131 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 222: Figure 3-62 Ivms8 And Ivms8R (S30122-Q7379-X, -K7379-Z)

    To reset the board to the default state, activate the lockout switch twice within the first 10 s of board startup. P31003-H3560-S403-54-7620, 09/05 3-132 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 223 Boards for HiPath 3000 Peripheral Boards Front view of IVMS8R X3 = LAN connector, 8-pin RJ45 jack LED (yellow) LED (green) Lockout switch Figure 3-63 IVMS8R - Front View (S30122-K7379-Z) P31003-H3560-S403-54-7620, 09/05 3-133 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 224 Tx + Transmit + Tx – Transmit – Rx + Receive + – Not used – Not used Rx – Receive – – Not used – Not used P31003-H3560-S403-54-7620, 09/05 3-134 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 225 Lockout switch activated during a call (500/ (500/ 500 ms) 500 ms) Board locked or board error occurred Check whether board was deac- tivated using HiPath 3000 Man- ager E or lockout switch. P31003-H3560-S403-54-7620, 09/05 3-135 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 226: Pbxxx (For Selected Countries Only)

    3000 Manager E. However, this is only visible in the software configuration, as the PBXXX card was only configured on the software side. Note: The offline configuration of the PBXXX serves solely to visualize the card with HiPath 3000 Manager E. P31003-H3560-S403-54-7620, 09/05 3-136 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 227 Port C (not used) Port D (not used) Port M (for connecting the service PC with the ECGM tool) Figure 3-64 PBXXX (S30810-Q6401-X) (for selected countries only) - Front Panel P31003-H3560-S403-54-7620, 09/05 3-137 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 228: Table 3-55 Pbxxx (For Selected Countries Only) - Seven-Segment Display

    PBXXX card active, Link 1 and Link 2 not active Link 1 active, Link 2 not active Link 1 not active, Link 2 active Link 1 active, Link 2 active Boot procedure P31003-H3560-S403-54-7620, 09/05 3-138 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 229: Figure 3-65 Hipath 3800 Basic Cabinet - 1X Diun2 + 1 X Pbxxx

    The CAS cable is connected to the backplane using an APPCU adapter (see Figure 3-66). Figure 3-65 HiPath 3800 Basic Cabinet - 1x DIUN2 + 1 x PBXXX P31003-H3560-S403-54-7620, 09/05 3-139 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 230: Figure 3-66 Pbxxx (For Selected Countries Only) - Connecting The Cas Cable

    PBXXX (for selected countries only) - Connecting the CAS Cable Using the APPCU Adapter The backplane of the PBXXX board must be closed with the adapter panels provided > (C39165-A7050-C35, Figure 3-67). P31003-H3560-S403-54-7620, 09/05 3-140 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 231: Figure 3-67 Pbxxx (For Selected Countries Only) - Adapter-Panel

    Boards for HiPath 3000 Peripheral Boards Figure 3-67 PBXXX (for selected countries only) – Adapter-Panel (C39165-A7050-C35) P31003-H3560-S403-54-7620, 09/05 3-141 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 232: Figure 3-68 Hipath 3800 Basic Cabinet - 1X Diun2 + 2 X Pbxxx

    The CAS cables are connected to the backplane using two APPCU adapters (see Figure 3- 69). Figure 3-68 HiPath 3800 Basic Cabinet - 1x DIUN2 + 2 x PBXXX P31003-H3560-S403-54-7620, 09/05 3-142 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 233: Figure 3-69 Pbxxx (For Selected Countries Only) - Connecting The Cas

    PBXXX (for selected countries only) - Connecting the CAS Cable Using Two APPCU Adapters The backplane of both PBXXX boards must be closed with the adapter panels pro- > vided (C39165-A7050-C35, Figure 3-67). P31003-H3560-S403-54-7620, 09/05 3-143 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 234 (T), receive BNC line, cable 1 b-wire (R), receive BNC shield, cable 1 a-wire (T), transmit BNC line, cable 2 b-wire (R), transmit BNC shield, cable 2 P31003-H3560-S403-54-7620, 09/05 3-144 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 235: Sla8N (Not For U.s.), Sla16N, Sla24N

    The operating mode (short or long line with the appropriate flash times) can be set up for each subscriber line interface with HiPath 3000 Manager E (the menu Settings: Set up station –> Station –> Parameters –> Flags). P31003-H3560-S403-54-7620, 09/05 3-145 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 236: Table 3-58 Sla8N (Not For U.s.), Sla16N, Sla24N - Led Statuses

    HiPath 3000 Manager E. not, replace board. Flashing Loadware is being loaded. Board test completed successfully. Board is OK (idle state). Flashing At least one station is activated. P31003-H3560-S403-54-7620, 09/05 3-146 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 237 Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk used blk/grn Port 13 SLA8N grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-147 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 238 Port 19 blu/blk blk/ora Port 20 used ora/blk blk/grn SLA8N, Port 21 SLA16N grn/blk blk/brn Port 22 brn/blk blk/gry Port 23 gry/blk yel/blu Port 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-148 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 239 Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk blk/grn Port 13 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-149 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 240: Table 3-61 Sla16N, Sla24N - Assignment (Su Xx8, Xx9) (For U.s. Only)

    Port 18 gry/red blk/blu Port 19 blu/blk blk/ora Port 20 ora/blk used blk/grn Port 21 SLA16N grn/blk blk/brn Port 22 brn/blk blk/gry Port 23 gry/blk yel/blu Port 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-150 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 241 ● Loop current detection > 10 mA ● Ground button detection > 20 mA ● The transmission method can be configured country-specifically by entering the country ● code. P31003-H3560-S403-54-7620, 09/05 3-151 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 242: Slc16N (Not For U.s.)

    CBCPR board (HiPath 3750 and HiPath 3700) or the plug-in subboard on the CBCC board (for HiPath 3550) to ensure clock accuracy (see Table 11-1). P31003-H3560-S403-54-7620, 09/05 3-152 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 243: Figure 3-71 Slc16N (S30810-Q2193-X100) (Not For U.s.)

    SLC16N (Not for U.S.) - LED Statuses Red LED Green Status Action Board not receiving power or not plugged in Check plug contact on correctly. board. Board is out of order. P31003-H3560-S403-54-7620, 09/05 3-153 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 244 Board test completed successfully. Board is OK (idle state). Flashing At least one subscriber line circuit is activat- Board disabled. Check whether board was deactivated using the lockout switch. P31003-H3560-S403-54-7620, 09/05 3-154 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 245: Table 3-63 Slc16N (Not For U.s.) - Cable Assignment

    P0/E blk/brn BS x: Access 14 port x brn/blk P0/E blk/gry BS x: Access 15 port x gry/blk P0/E yel/blu BS x: Access 16 port x blu/yel P0/E P31003-H3560-S403-54-7620, 09/05 3-155 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 246 SLC16N, an SLMO24 or a TS2 on a PCM seg- ment. This condition must always be observed. For information on PCM segment distribution, see Page 4-158. P31003-H3560-S403-54-7620, 09/05 3-156 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 247 SLC16N (Not for U.S.) HiPath 3750 Number of Number of base stations Number of HiPath 3700 SLC16N SLA24N BS3/1 BS2/2 SLMO24 BS3/3 connected via connected via P0/E P0/E Expansion cabinet P31003-H3560-S403-54-7620, 09/05 3-157 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 248 1xU P0/E 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50 optiset E and optiPoint 500 telephones SLC16N P31003-H3560-S403-54-7620, 09/05 3-158 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 249: Table 3-65 Hipath 3550 - Maximum Number Of Corded Telephones Depending On The

    2xU P0/E 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50 optiset E and optiPoint 500 telephones SLC16N P31003-H3560-S403-54-7620, 09/05 3-159 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 250 Signal propagation times differ due to the varying distances between the base stations, the sys- tem, and the connection cables used (refer to the HiPath Cordless Office service manual). The SLC16N board automatically balances these propagation times. P31003-H3560-S403-54-7620, 09/05 3-160 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 251 BS3/1 for in- HiPath 3550, doors HiPath 3700 CABLU P0/E SLC16N Splitting strip MDFU, MDFU-E Figure 3-72 Base Station Power Supply via One U Interface (Not for U.S.) P0/E P31003-H3560-S403-54-7620, 09/05 3-161 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 252: Figure 3-73 Base Station Power Supply Via Two U P0/E Interfaces (Not For U.s.)

    HiPath 3550, for indoors HiPath 3700 CABLU P0/E SLC16N P0/E Splitting strip MDFU, MDFU-E Figure 3-73 Base Station Power Supply via Two U Interfaces (Not for U.S.) P0/E P31003-H3560-S403-54-7620, 09/05 3-162 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 253 Path 3300, you should use the EPSU2-R power supply. This is installed in the ECR expansion cabinet rack (see Section 9.2.4). Section 11.5, “Power-Related Capacity Limits” shows which telephone configurations manage without an additional power supply and which configurations require an additional one. P31003-H3560-S403-54-7620, 09/05 3-163 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 254 The new EPSU2 model S30122-K7221-X2 is designed to replace S30122- > K7221-X1. Differences between the two models are indicated at the appropriate point in the following description. P31003-H3560-S403-54-7620, 09/05 3-164 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 255: Figure 3-75 Epsu2 - Indicators And Ports

    DC port for UPSC-D Note polarity. Housing cover Battery fuse Mounting LED 1 screws LED 2 AC port for 100 – 240 Vac Figure 3-75 EPSU2 - Indicators and Ports P31003-H3560-S403-54-7620, 09/05 3-165 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 256 DC cable to UPSC-D ● DC cable to UPSC-D (length = 2 m) ● (length = 2 m) AC power cable C39195-Z7001-C17 Euro angled ● C39195-Z7001-C20 GBR angled ● P31003-H3560-S403-54-7620, 09/05 3-166 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 257 14.1 kg (incl. batteries) approx. 4.1 kg (without batter- ies) Symbol Personal safety, insulation EN60950 and IEC950 Grounding, shielding Protection class 1, output is floating against ground P31003-H3560-S403-54-7620, 09/05 3-167 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 258: Figure 3-76 Epsu2 - Holes For Mounting On The Wall

    Mount the EPSU2 onto the screws and tighten them all the way. 115 mm 102 mm 33 mm 317 mm Figure 3-76 EPSU2 - Holes for Mounting on the Wall P31003-H3560-S403-54-7620, 09/05 3-168 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 259: Slcn (Not For U.s.)

    SLCN (S30810-Q2193-X300) - LEDs on the Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-169 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 260: Table 3-70 Slcn:led Statuses

    For connecting to the SIVAPAC connector on the backplane: Table 3-71 ● For connecting to the connector panels using RJ45 jacks: Table 3-72 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-73 ● P31003-H3560-S403-54-7620, 09/05 3-170 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 261: Table 3-71 Slcn - Sivapac Connector Assignment On The Backplane

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk blk/grn Port 13 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-171 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 262: Table 3-72 Slcn - Connector Panel Assignment With Rj45 Jacks

    Boards for HiPath 3000 Peripheral Boards Table 3-72 SLCN - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLCN Notes P31003-H3560-S403-54-7620, 09/05 3-172 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 263 Boards for HiPath 3000 Peripheral Boards Table 3-72 SLCN - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLCN Notes Free Free Free Free Free Free Free Free P31003-H3560-S403-54-7620, 09/05 3-173 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 264: Table 3-73 Slcn - Connector Panel Assignment With Sipac 1 Su Connectors

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk blk/grn Port 13 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-174 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 265 If the correct number of LUNA2 modules was calculated, the system’s internal power supply unit provides sufficient power to supply the HiPath Cordless Office system configuration spec- ified in Table 11-1. P31003-H3560-S403-54-7620, 09/05 3-175 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 266: Slma, Slma8

    SLMA/SLMA8 - LEDs on the Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-176 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 267: Table 3-74 Slma/Slma8 - Led Statuses

    For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-77 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-78 and ● Table 3-79 P31003-H3560-S403-54-7620, 09/05 3-177 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 268: Table 3-75 Slma/Slma8 - Sivapac Connector Assignment On The Backplane

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk used blk/grn Port 13 SLMA8 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-178 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 269 Port 18 grn/yel yel/brn Port 19 brn/yel yel/gry Port 20 gry/yel used vio/blu Port 21 SLMA8 blu/vio vio/ora Port 22 ora/vio vio/grn Port 23 grn/vio vio/brn Port 24 brn/vio P31003-H3560-S403-54-7620, 09/05 3-179 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 270: Table 3-76 Slma/Slma8 - Connector Panel Assignment With Rj45 Jacks

    Boards for HiPath 3000 Peripheral Boards Table 3-76 SLMA/SLMA8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA, SLMA8 Notes Not used for SLMA8 P31003-H3560-S403-54-7620, 09/05 3-180 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 271 Boards for HiPath 3000 Peripheral Boards Table 3-76 SLMA/SLMA8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA, SLMA8 Notes Not used for SLMA8 P31003-H3560-S403-54-7620, 09/05 3-181 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 272 12 TIP used 13 Ring Port 13 SLMA8 13 TIP 14 Ring Port 14 14 TIP 15 Ring Port 15 15 TIP 16 Ring Port 16 16 TIP P31003-H3560-S403-54-7620, 09/05 3-182 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 273: Table 3-77 Slma/Slma8 - Connector Panel Assignment With Champ Jack

    20 TIP used 21 Ring Port 21 SLMA8 21 TIP 22 Ring Port 22 22 TIP 23 Ring Port 23 23 TIP 24 Ring Port 24 24 TIP P31003-H3560-S403-54-7620, 09/05 3-183 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 274: Table 3-78 Slma, Slma8 - Connector Panel Assignment With Sipac 1 Su Connectors (Cable For Ports 1 - 16)

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk used blk/grn Port 13 SLMA8 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-184 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 275 Port 18 gry/red blk/blu Port 19 blu/blk blk/ora Port 20 ora/blk used blk/grn Port 21 SLMA8 grn/blk blk/brn Port 22 brn/blk blk/gry Port 23 gry/blk yel/blu Port 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-185 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 276: Slma2 (For Selected Countries Only)

    SLMA2 (S30810-Q2246-X) (for selected countries only) - LED’s on the Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-186 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 277: Table 3-80 Slma2 (For Selected Countries Only) - Led Statuses

    For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-77 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-78 and ● Table 3-79 P31003-H3560-S403-54-7620, 09/05 3-187 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 278: Table 3-81 Slma2 (For Selected Countries Only) - Sivapac Connector Assignment On The Backplane

    9 brn/red red/gry port 10 gry/red blk/blu port 11 blu/blk blk/ora port 12 ora/blk blk/grn port 13 grn/blk blk/brn port 14 brn/blk blk/gry port 15 gry/blk P31003-H3560-S403-54-7620, 09/05 3-188 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 279 18 grn/yel yel/brn port 19 brn/yel yel/gry port 20 gry/yel vio/blu port 21 blu/vio vio/ora port 22 ora/vio vio/grn port 23 grn/vio vio/brn port 24 brn/vio P31003-H3560-S403-54-7620, 09/05 3-189 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 280 Boards for HiPath 3000 Peripheral Boards Table 3-82 SLMA2 (for selected countries only) - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA2 Notes P31003-H3560-S403-54-7620, 09/05 3-190 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 281 Boards for HiPath 3000 Peripheral Boards Table 3-82 SLMA2 (for selected countries only) - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMA2 Notes P31003-H3560-S403-54-7620, 09/05 3-191 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 282 12 12 TIP 13 Ring port 13 13 TIP 14 Ring port 14 14 TIP 15 Ring port 15 15 TIP 16 Ring port 16 16 TIP P31003-H3560-S403-54-7620, 09/05 3-192 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 283 20 20 TIP 21 Ring port 21 21 TIP 22 Ring port 22 22 TIP 23 Ring port 23 23 TIP 24 Ring port 24 24 TIP P31003-H3560-S403-54-7620, 09/05 3-193 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 284 10 gry/red blk/blu port 11 blu/blk blk/ora port 12 ora/blk blk/grn port 13 grn/blk blk/brn port 14 brn/blk blk/gry port 15 gry/blk yel/blu port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-194 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 285 18 gry/red blk/blu port 19 blu/blk blk/ora port 20 ora/blk blk/grn port 21 grn/blk blk/brn port 22 brn/blk blk/gry port 23 gry/blk yel/blu port 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-195 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 286: Slmo2, Slmo8

    SLMO2/SLMO8 - LEDs on the Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-196 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 287: Table 3-86 Slmo2 And Slmo8 - Led Statuses

    For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-89 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-90 and ● Table 3-91 P31003-H3560-S403-54-7620, 09/05 3-197 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 288: Table 3-87 Slmo2/Slmo8 - Sivapac Connector Assignment On The Backplane

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk used blk/grn Port 13 SLMO8 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-198 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 289 Port 18 grn/yel yel/brn Port 19 brn/yel yel/gry Port 20 gry/yel used vio/blu Port 21 SLMO8 blu/vio vio/ora Port 22 ora/vio vio/grn Port 23 grn/vio vio/brn Port 24 brn/vio P31003-H3560-S403-54-7620, 09/05 3-199 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 290: Table 3-88 Slmo2/Slmo8 - Connector Panel Assignment With Rj45 Jacks

    Boards for HiPath 3000 Peripheral Boards Table 3-88 SLMO2/SLMO8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMO2, SLMO8 Notes Not used for SLMO8 P31003-H3560-S403-54-7620, 09/05 3-200 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 291 Boards for HiPath 3000 Peripheral Boards Table 3-88 SLMO2/SLMO8 - Connector Panel Assignment with RJ45 Jacks RJ45 jack SLMO2, SLMO8 Notes Not used for SLMO8 P31003-H3560-S403-54-7620, 09/05 3-201 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 292 Not used for SLMO8 13 Ring Port 13 13 TIP 14 Ring Port 14 14 TIP 15 Ring Port 15 15 TIP 16 Ring Port 16 16 TIP P31003-H3560-S403-54-7620, 09/05 3-202 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 293: Table 3-89 Slmo2/Slmo8 - Connector Panel Assignment With Champ Jack

    Not used for SLMO8 21 Ring Port 21 21 TIP 22 Ring Port 22 22 TIP 23 Ring Port 23 23 TIP 24 Ring Port 24 24 TIP P31003-H3560-S403-54-7620, 09/05 3-203 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 294: Table 3-90 Slmo2/Slmo8 - Connector Panel Assignment With Sipac 1 Su Connectors (Cable For Ports 1 - 16)

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk used blk/grn Port 13 SLMO8 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-204 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 295 Port 18 gry/red blk/blu Port 19 blu/blk blk/ora Port 20 ora/blk used blk/grn Port 21 SLMO8 grn/blk blk/brn Port 22 brn/blk blk/gry Port 23 gry/blk yel/blu Port 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-205 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 296: Slmo8 (Not For U.s.), Slmo24

    Path 3550 and HiPath 3700. Switches and LEDs Lockout switch S1 (position = free, factory default) H1 (green) LEDs H2 (red) Figure 3-81 SLMO8 (Not for U.S.), SLMO24 (S30810-Q2901-X100, S30810-Q2901-X) P31003-H3560-S403-54-7620, 09/05 3-206 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 297: Table 3-92 Slmo8 (Not For U.s.) And Slmo24 - Led Statuses

    HiPath 3000 Manager E. not, replace board. Flashing Loadware is being loaded. Board test completed successfully. Board is OK (idle state). Flashing At least one subscriber line circuit is activat- P31003-H3560-S403-54-7620, 09/05 3-207 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 298: Table 3-93 Slmo8 (Not For U.s.), Slmo24 - Cable 1 Assignment (Su Xx8)

    Access 10 gry/red blk/blu Access 11 blu/blk blk/ora Access 12 ora/blk used blk/grn Access 13 SLMO8 grn/blk blk/brn Access 14 brn/blk blk/gry Access 15 gry/blk yel/blu Access 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-208 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 299 Access 18 gry/red blk/blu Access 19 blu/blk blk/ora Access 20 ora/blk used blk/grn Access 21 SLMO8 grn/blk blk/brn Access 22 brn/blk blk/gry Access 23 gry/blk yel/blu Access 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-209 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 300: Table 3-95 Slmo24 - Assignment (Su Xx8, Xx9) (For U.s. Only)

    Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk blk/grn Port 13 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-210 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 301 Port 18 gry/red blk/blu Port 19 blu/blk blk/ora Port 20 ora/blk blk/grn Port 21 grn/blk blk/brn Port 22 brn/blk blk/gry Port 23 gry/blk yel/blu Port 24 blu/yel P31003-H3560-S403-54-7620, 09/05 3-211 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 302: Slu8

    SLU8 in or out. If you do not wait before doing so, the CBCC/CBCP may be dam- aged. Table 3-96 SLU8 Contact Assignments Contact X2 (U ports 1-4) X3 (U ports 5-8) Po/E P0/E P31003-H3560-S403-54-7620, 09/05 3-212 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 303: Slu8R

    P0/E Figure 3-83 SLU8R Interfaces (S30817-K922-Z301) Table 3-97 SLU8R Contact Assignments X2, pin ports X2, pin ports P0/E P0/E jack 1 - 4 jack 5 - 8 P31003-H3560-S403-54-7620, 09/05 3-213 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 304: Stls2 (Not For U.s.), Stls4

    3 = SR + 4 = SR - 5 = SX - SX = Signal transmit SR = signal receive Figure 3-84 STLS2 (Not for U.S.), STLS4 Interfaces (S30817-Q924-B313, -A313) P31003-H3560-S403-54-7620, 09/05 3-214 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 305 The system assigns the MSN only after the S port is configured on the "Euro bus" (not for U.S.) and can be read out via the administration (Assistant T: Code 20 4 3 S Bus MSN). P31003-H3560-S403-54-7620, 09/05 3-215 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 306 Networking connection (HiPath 4000/CorNet NQ (not for U.S.) Insert the connection cable supplied in jacks S 1 to S 4. Connect the other end with the HiPath 4000 port. P31003-H3560-S403-54-7620, 09/05 3-216 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 307: Figure 3-85 Sample Pin Assignments In Mw Jacks (Not For U.s.)

    SX SX SR SX SX SR 4-pin Always establish contact on the center four pins. SX SX SR Figure 3-85 Sample Pin Assignments in MW Jacks (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-217 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 308: Figure 3-86 Wiring And Ranges For S Bus Jacks (Not For U.s.)

    Terminating resistor in last jack Maximum ranges: System Short bus: 150 m (492 ft.) Long bus: 150 m (492 ft.) Figure 3-86 Wiring and Ranges for S Bus Jacks (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-218 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 309 SR = signal receive With MW cables, contact is always es- tablished in the center of the connec- SX SX SR tor. Figure 3-87 MWxx Jack Pin Assignment (For U.S. Only) P31003-H3560-S403-54-7620, 09/05 3-219 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 310: Figure 3-88 S Bus Wiring From Stls4 Port Or Optiset E Isdn Adapter

    Last device jack (8-pin MW8) 100 ohms, 0.25 W Terminating resistor in last jack Figure 3-88 Bus Wiring from STLS4 Port or optiset E ISDN Adapter (For U.S. Only) P31003-H3560-S403-54-7620, 09/05 3-220 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 311: Stls4R

    3 = SX + 4 = SR + 5 = SR – 6 = SX – SX = Signal transmit SR = signal receive Figure 3-89 STLS4R Interfaces (S30817-K924-Z313) P31003-H3560-S403-54-7620, 09/05 3-221 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 312: Table 3-99 Stls4R Contact Assignments

    3 transmit– port 4 transmit+ port 4 receive+ port 4 receive– port 4 transmit– Refer to Page 3-216 for information on connecting ISDN lines and telephones. > P31003-H3560-S403-54-7620, 09/05 3-222 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 313: Stlsx2, Stlsx4, Stlsx4R

    (PMP bus) in NT (network terminator) mode with cross-connected RX-TX lines. Interfaces The board does not supply terminals with power. Power must be supplied locally for > telephones, for example, via a plug-in power supply unit. P31003-H3560-S403-54-7620, 09/05 3-223 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 314 Receive + Receive – Receive – Receive – Receive – Transmit – Transmit – Transmit – Transmit – – – – – – – – – Not for STLSX2 P31003-H3560-S403-54-7620, 09/05 3-224 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 315 S interfaces S 2 to S 4 to the ISDN trunk or to ISDN terminals (ISDN telephone, group 4 fax device, PC, dialing aid) via an S bus. P31003-H3560-S403-54-7620, 09/05 3-225 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 316: Figure 3-91 Pin Assignments In Mw Jacks

    Assignment of MW jack pins 1- 8: 8-pin 6-pin SX SX SR SX SX SR 4-pin Always establish contact on the center four pins. SX SX SR Figure 3-91 Pin Assignments in MW Jacks P31003-H3560-S403-54-7620, 09/05 3-226 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 317: Figure 3-92 Wiring And Ranges For S Bus Jacks

    Terminating resistor in last jack Maximum ranges: System Short bus: 150 m (492 ft.) Long bus: 150 m (492 ft.) Figure 3-92 Wiring and Ranges for S Bus Jacks P31003-H3560-S403-54-7620, 09/05 3-227 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 318: Stmd3

    STMD3 (S30810-Q2217-X10) - LEDs on the Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-228 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 319: Table 3-101 Stmd3 - Led Statuses

    For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-104 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-105 ● P31003-H3560-S403-54-7620, 09/05 3-229 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 320: Table 3-102 Stmd3 - Sivapac Connector Assignment On The Backplane

    5 red/gry gry/red blk/blu blu/blk Basic rate access 6 blk/ora ora/blk blk/grn grn/blk Basic rate access 7 blk/brn brn/blk blk/gry gry/blk Basic rate access 8 yel/blu blu/yel P31003-H3560-S403-54-7620, 09/05 3-230 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 321: Table 3-103 Stmd3 - Connector Panel Assignment With Rj45 Jacks

    Basic rate access 2 Basic rate access 3 Basic rate access 4 Basic rate access 5 Basic rate access 6 Basic rate access 7 Basic rate access 8 P31003-H3560-S403-54-7620, 09/05 3-231 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 322 , Transmit , Transmit , Receive , Receive Basic rate access 7 , Transmit , Transmit , Receive , Receive Basic rate access 8 , Transmit , Transmit P31003-H3560-S403-54-7620, 09/05 3-232 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 323 Basic brn/red rate access red/gry gry/red blk/blu Basic blu/blk rate access blk/ora ora/blk blk/grn Basic grn/blk rate access blk/brn brn/blk blk/gry Basic gry/blk rate access yel/blu blu/yel P31003-H3560-S403-54-7620, 09/05 3-233 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 324: Stmd8

    S0 bus for connecting ISDN telephones (not for U.S.) (separate power supply re- ● quired). Switches and LEDs H300 LEDs H301 H308 Lockout switch S300 Figure 3-94 STMD8 (S30810-Q2558-X200) P31003-H3560-S403-54-7620, 09/05 3-234 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 325 Board is out of service (e.g. S300/x Check whether board was deactivat- (500/500 ms) “closed”) ed using HiPath 3000 Manager E or lockout switch. ISDN layer 2 not activated P31003-H3560-S403-54-7620, 09/05 3-235 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 326: Figure 3-95 S Trunk Connection (Example For Hipath 3750)

    NT Connection(Not for U.S.) When starting up S ports during operation with PABXs, it is important to ensure that > the NT switch is in the POINT-TO-POINT position. P31003-H3560-S403-54-7620, 09/05 3-236 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 327 Use a point-to-point connection if you have a dedicated line (trunk circuit/tie trunk circuit) or to extend the range if only one telephone is connected to the S bus. P31003-H3560-S403-54-7620, 09/05 3-237 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 328: Figure 3-97 S Networking Options (Not For U.s.) (Examples For Hipath 3750)

    STMD8 STMD8 MDFU-E Fixed connection via public network (NT connection according to Figure 3-96) MDFU Cable (CABLU) Figure 3-97 Networking Options (Not for U.S.) (Examples for HiPath 3750) P31003-H3560-S403-54-7620, 09/05 3-238 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 329: Figure 3-98 S Bus To The Stmd8 Over The Mdfu Or Mdfu-E (Not For U.s.)

    Assignment of MW jack pins 1- 8: 8-pin 6-pin SX SX SR SX SX SR 4-pin Always establish contact on the center four pins. SX SX SR Figure 3-99 Pin Assignments in MW Jacks P31003-H3560-S403-54-7620, 09/05 3-239 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 330: Figure 3-100 S Bus - Example Of Jack Assignment (Not For U.s.)

    ISDN boards can also be connected to available optiPoint 500 series telephones (ex- > cept for optiPoint 500 entry and optiPoint 500 economy) using an optiPoint ISDN Adapter. P31003-H3560-S403-54-7620, 09/05 3-240 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 331 Basic brn/red rate access red/gry gry/red blk/blu Basic blu/blk rate access blk/ora ora/blk blk/grn Basic grn/blk rate access blk/brn brn/blk blk/gry Basic gry/blk rate access yel/blu blu/yel P31003-H3560-S403-54-7620, 09/05 3-241 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 332: Table 3-108 Stmd8 - Assignment (Suxx8) (For U.s. Only)

    7 Transmit – brn/blk 7 Transmit + blk/gry 8 Receive – gry/blk 8 Receive + Port 8 yel/blu 8 Transmit – blu/yel 8 Transmit + No other wires used. P31003-H3560-S403-54-7620, 09/05 3-242 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 333 MW8 jack 1 adapter). (8-pin) (8-pin) STMD8 port on MDF (port 1 shown) Figure 3-101 STMD8 - S Bus Wiring from STMD8 Port or from ISDN Adapter (for U.S. only) P31003-H3560-S403-54-7620, 09/05 3-243 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 334: Stmi2

    Board Part number Services DSPs B channels DSP channels STMI2 S30810-Q2316-X100 Voice and Data Sixteen simultaneous Voice over IP connections are possible per DSP (Digital Signal Proces- sor). P31003-H3560-S403-54-7620, 09/05 3-244 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 335 PDMX S30807-Q5697- The PDMX extension module (PMC DSP X200 is not released at present. Module Ex- tended) slot 1 slot 0 Figure 3-102 STMI2 (S30810-Q2316-X100) - HGA Slots P31003-H3560-S403-54-7620, 09/05 3-245 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 336 Two RJ45 jacks for LAN interfaces. These provide access to the Ethernet standard (IEEE ● 802.3) with 10 Mbps or 100 Mbps with automatic configuration. Manual configuration is also possible. 9-pin Sub-D plug for V.24 interface ● P31003-H3560-S403-54-7620, 09/05 3-246 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 337: Figure 3-103 Stmi2 - Front Panel

    Yellow = 10 Mbps online (link) – Flashing = active LED2 (green): ● – On = full-duplex (FDX) – Off = half-duplex Figure 3-103 STMI2 - Front Panel P31003-H3560-S403-54-7620, 09/05 3-247 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 338 Signal Remark Not used Internal pull-up resistor in level switch (MAX211E) Ground Internal pull-up resistor in level switch (MAX211E) Internal pull-up resistor in level switch (MAX211E) Not used P31003-H3560-S403-54-7620, 09/05 3-248 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 339 Signals TT1/2 and RT1/2 are not needed for transmitting data. They represent a signal termi- nation of 100 ohms (so-called Bob Smith termination) for the two unused wire pairs in a 4-pair twisted pair cable. P31003-H3560-S403-54-7620, 09/05 3-249 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 340: Tiel

    Before you can start up a tie trunk, you must determine the type of interface supported by the two systems. Type 2 is preferable because it virtually excludes problems with longitudinal volt- ages. P31003-H3560-S403-54-7620, 09/05 3-250 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 341 E&M interface type 3 ● This type uses four signal wires. The M-signal has GND or V (- 48 V) for direct TIEL- battery to-TIEL connection (without converter). P31003-H3560-S403-54-7620, 09/05 3-251 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 342 It differs from the wink signal protocol only in that the remote system returns a backward signal immediately after seizure even if it is not ready for digit input. P31003-H3560-S403-54-7620, 09/05 3-252 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 343 (S1/1 to 4, S1/5 to 8 = used S1/8 for factory testing) S202 S104 S103 S203 v S204 S302 S303 S304 S402 S403 S404 Figure 3-104 TIEL (S30810-Q2520-X) P31003-H3560-S403-54-7620, 09/05 3-253 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 344 1 - 2 S204 1 - 2 S304 1 - 2 S404 1 - 2 (factory default) 4 - 5 4 - 5 4 - 5 4 - 5 P31003-H3560-S403-54-7620, 09/05 3-254 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 345 CCT 3: S303 S302 CCT 3: S303 S302 CCT 4: S403 S402 CCT 4: S403 S402 System A System B Figure 3-105 E&M Interface Type 1 (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-255 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 346: Figure 3-106 E&M Interface Type 1A (Not For U.s.)

    CCT 2: S203 S202 CCT 3: S303 S302 CCT 3: S303 S302 CCT 4: S403 S402 CCT 4: S403 S402 Figure 3-106 E&M Interface Type 1A (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-256 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 347: Figure 3-107 E&M Interface Type 1B Or 5 (Not For U.s.)

    S202 CCT 3: S303 S302 CCT 3: S303 S302 CCT 4: S403 S402 CCT 4: S403 S402 Figure 3-107 E&M Interface Type 1B or 5 (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-257 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 348: Figure 3-108 E&M Interface Type 2 (Not For U.s)

    CCT 2: S203 S202 CCT 3: S303 S302 CCT 3: S303 S302 CCT 4: S403 S402 CCT 4: S403 S402 Figure 3-108 E&M Interface Type 2 (Not for U.S) P31003-H3560-S403-54-7620, 09/05 3-258 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 349 S103 going signaling 8 b 12 b 16 b - 48 V Figure 3-109 E&M Interface Type 2 - Circuit Diagram, MDFU or MDFU-E Numbering (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-259 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 350 Circuit out of service (e.g. S1/x in Check whether the circuit was deacti- 500 ms) “on” position”) vated with HiPath 3000 Manager E or lockout switch. Circuit is idle, no seizure P31003-H3560-S403-54-7620, 09/05 3-260 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 351 Transmit + ● gry/wht receive with 2-wire speech red/blu Ring Receive with 4- Port wire speech blu/red red/ora System ora/red ground Signal wires red/grn Mouth System grn/red battery P31003-H3560-S403-54-7620, 09/05 3-261 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 352 Transmit + ● grn/blk receive with 2-wire speech blk/brn Ring Receive with 4- Port wire speech brn/blk blk/gry System gry/blk ground Signal wires yel/blu Mouth System blu/yel battery P31003-H3560-S403-54-7620, 09/05 3-262 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 353 Transmit + receive with ● brn/red 2-wire speech red/gry Ring 1 Receive with 4-wire speech Port 3 gry/red TIP 1 blk/blu blu/blk System ground Signal wires blk/ora ora/blk System battery P31003-H3560-S403-54-7620, 09/05 3-263 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 354 2-wire speech blk/brn Ring 1 Receive with 4-wire speech Port 4 brn/blk TIP 1 blk/gry gry/blk System ground Signal wires yel/blu blu/yel System battery No other wires used. P31003-H3560-S403-54-7620, 09/05 3-264 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 355: Tla2 (Not For U.s.), Tla4 (Not For U.s.), Tla8 (Not For U.s.)

    3 b trunk 3 a trunk 4 a trunk 3 b trunk 4 b trunk 4 a trunk 4 Call charging module assignment (GMZ) Not for TLA2 P31003-H3560-S403-54-7620, 09/05 3-265 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 356 8 a trunk 4 – – a trunk 8 GMZ 1 – – GMZ 2 GMZ= Call charging module assignment GND=GND for GEE50 FKR, otherwise free P31003-H3560-S403-54-7620, 09/05 3-266 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 357: Tla4R (Not For U.s.)

    TLA4R (Not for U.S.) Interfaces (S30817-Q923-Zxxx) Table 3-119 TLA4R (Not for U.S.) Contact Assignments MW8 Jack X5, pin Trunk connections 1-4 a trunk 1 b trunk 1 a trunk 2 b trunk 2 P31003-H3560-S403-54-7620, 09/05 3-267 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 358: Table 3-119 Tla4R (Not For U.s.) Contact Assignments

    4 b trunk 4 MW8 Jack X5, pin ALUM 1 + 2 ALUM1: Stn card connection ALUM2: Stn card connection ALUM1: Analog telephone connection ALUM2: Analog telephone connection P31003-H3560-S403-54-7620, 09/05 3-268 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 359: Tm2Lp

    TM2LP - Front Panel (S30810-Q2159-Xxxx) To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-269 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 360: Table 3-120 Tm2Lp - Led Statuses

    For U.S. only: For connecting to the connector panels with CHAMP jack: Table 3-123 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-124 ● P31003-H3560-S403-54-7620, 09/05 3-270 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 361: Table 3-121 Tm2Lp - Sivapac Connector Assignment On The Backplane

    Port 8 grn/red red/brn Free brn/red red/gry Free gry/red blk/blu Free blu/blk blk/ora Free ora/blk blk/grn Free grn/blk blk/brn Free brn/blk blk/gry Free gry/blk yel/blu Free blu/yel P31003-H3560-S403-54-7620, 09/05 3-271 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 362: Table 3-122 Tm2Lp - Connector Panel Assignment With Rj45 Jacks

    Boards for HiPath 3000 Peripheral Boards Table 3-122 TM2LP - Connector Panel Assignment with RJ45 Jacks RJ45 jack TM2LP Notes Free Free Free Free Free Free Free Free P31003-H3560-S403-54-7620, 09/05 3-272 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 363 Boards for HiPath 3000 Peripheral Boards Table 3-122 TM2LP - Connector Panel Assignment with RJ45 Jacks RJ45 jack TM2LP Notes Free Free Free Free Free Free Free Free P31003-H3560-S403-54-7620, 09/05 3-273 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 364 5 TIP 6 Ring Port 6 6 TIP 7 Ring Port 7 7 TIP 8 Ring Port 8 8 TIP Free Free Free Free Free Free Free Free P31003-H3560-S403-54-7620, 09/05 3-274 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 365: Table 3-124 Tm2Lp - Connector Panel Assignment With Sipac 1 Su Connectors

    Port 8 grn/red red/brn Free brn/red red/gry Free gry/red blk/blu Free blu/blk blk/ora Free ora/blk blk/grn Free grn/blk blk/brn Free brn/blk blk/gry Free gry/blk yel/blu Free blu/yel P31003-H3560-S403-54-7620, 09/05 3-275 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 366: Tmamf (For Selected Countries Only)

    S30810-Q2587-A400 for use in HiPath 3550. ● Switches and LEDs LEDs H0 (green) H100 (yellow) Lockout switch S501 (factory default) Subminiature D connector for DSP diagnosis Figure 3-114 TMAMF (S30810-Q2587-Axxx) P31003-H3560-S403-54-7620, 09/05 3-276 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 367: Figure 3-115 Pin Assignments Of The Tmamf Diagnostic Cable

    Pin assignments of the diagnostic cable TMAMF: Subminiature D connector PC: RS-232 interface 2 3 4 5 6 7 8 9 Figure 3-115 Pin Assignments of the TMAMF Diagnostic Cable P31003-H3560-S403-54-7620, 09/05 3-277 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 368 The trunk was seized Flashing Trunk out of service (e.g. S1/x Check whether the trunk was de- (500/500 ms) “closed”) activated using HiPath 3000 Manager E or the lockout switch. P31003-H3560-S403-54-7620, 09/05 3-278 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 369: Table 3-127 Tmamf - Cable Assignment

    Port 8 grn/red red/brn Free brn/red red/gry Free gry/red blk/blu Free blu/blk blk/ora Free ora/blk blk/grn Free grn/blk blk/brn Free brn/blk blk/gry Free gry/blk yel/blu Free blu/yel P31003-H3560-S403-54-7620, 09/05 3-279 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 370: Tmc16 (For Selected Countries Only)

    TMC16 (for selected countries only) (S30810-Q2485-X) - Front Panel To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-280 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 371: Table 3-128 Tmc16 (For Selected Countries Only) - Led Statuses

    For connecting to the SIVAPAC connector on the backplane: Table 3-129 ● For connecting to the connector panels with CHAMP jack: Table 3-130 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-131 ● P31003-H3560-S403-54-7620, 09/05 3-281 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 372 Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk blk/grn Port 13 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-282 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 373 Port 12 12 TIP 13 Ring Port 13 13 TIP 14 Ring Port 14 14 TIP 15 Ring Port 15 15 TIP 16 Ring Port 16 16 TIP P31003-H3560-S403-54-7620, 09/05 3-283 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 374 Port 10 gry/red blk/blu Port 11 blu/blk blk/ora Port 12 ora/blk blk/grn Port 13 grn/blk blk/brn Port 14 brn/blk blk/gry Port 15 gry/blk yel/blu Port 16 blu/yel P31003-H3560-S403-54-7620, 09/05 3-284 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 375: Tmcas (For Selected Countries Only)

    Administration of the CAS protocol converter Use the ECGM tool for administration. For information on installing the software on the service PC and on the required settings, see Page 3-293. P31003-H3560-S403-54-7620, 09/05 3-285 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 376 “On”). S4-7 Reserved S4-8 Battery: Select the “On” switch position to make the connection to the processor’s real-time clock only after the protocol convert- er has been configured. P31003-H3560-S403-54-7620, 09/05 3-286 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 377 Do not ground the shield on both ends of the cable. – Tx: Ground the cable’s shield on the TMCAS side. – Rx: Ground the cable’s shield on the side of the connected device (NT, MUX, modem). P31003-H3560-S403-54-7620, 09/05 3-287 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 378 Waiting for ECGM command (10 s) Calculating the checksum No TMCAS software in the flash memory, waiting for reload Flash memory erased (changing display) TMCAS board active TMCAS board active, boot process completed P31003-H3560-S403-54-7620, 09/05 3-288 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 379 (T), transmit b-wire (R), transmit +5 V for board detection +5 V (reserved) Page 3-291 has information on the assignments for the two C39195-A9700-B512, -B514 TM- CAS cables. P31003-H3560-S403-54-7620, 09/05 3-289 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 380 +5 V for board detection a-wire (T), receive b-wire (R), receive a-wire (T), transmit b-wire (R), transmit Page 3-291 has information on the assignments for the two C39195-A9700-B512, -B514 TM- CAS cables. P31003-H3560-S403-54-7620, 09/05 3-290 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 381 (T), receive BNC shield, cable 1 b-wire (R), receive BNC signal, cable 1 a-wire (T), transmit BNC shield, cable 2 b-wire (R), transmit BNC signal, cable 2 P31003-H3560-S403-54-7620, 09/05 3-291 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 382 HiPath 3000 Manager E immediately to the left of the TMS2 (Hi- Path 3750 and HiPath 3700) or in the HiPath 3550’s large slot, the generation is rejected. P31003-H3560-S403-54-7620, 09/05 3-292 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 383 X130aq.pnm (PNM file) ● Execute Setup.exe file. This will create the directory ecgm and extract various files. Copy vbrazil.iyy (for example, 4brazil.iam) to the directory ecgm. Run the file ecgm.exe. P31003-H3560-S403-54-7620, 09/05 3-293 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 384 Database menu. This procedure takes approximately 8 minutes. The download is complete when the configured channels display the “Idle” status. The seven-segment display H1 on the TMCAS shows “A” (= active). P31003-H3560-S403-54-7620, 09/05 3-294 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 385: Tmdid (For U.s. Only)

    Slow flashing The trunk circuit was deactivated by the software. Fast flashing The switch was pressed and the trunk circuit was selected for manual acti- vation or deactivation. P31003-H3560-S403-54-7620, 09/05 3-295 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 386: Figure 3-120 Tmdid (For U.s. Only) (S30810-Q2452-X) - Front Panel

    For connecting to the SIVAPAC connector on the backplane: Table 3-138 ● For connecting to the connector panels with CHAMP jack: Table 3-139 ● For connecting to the connector panels using SIPAC 1 SU connectors: Table 3-140 ● P31003-H3560-S403-54-7620, 09/05 3-296 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 387 Port 8 grn/red red/brn Free brn/red red/gry Free gry/red blk/blu Free blu/blk blk/ora Free ora/blk blk/grn Free grn/blk blk/brn Free brn/blk blk/gry Free gry/blk yel/blu Free blu/yel P31003-H3560-S403-54-7620, 09/05 3-297 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 388 Port 5 5 TIP 6 Ring Port 6 6 TIP Ring Port 7 7 TIP 8 Ring Port 8 8 TIP Free Free Free Free Free Free Free Free P31003-H3560-S403-54-7620, 09/05 3-298 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 389 Port 8 grn/red red/brn Free brn/red red/gry Free gry/red blk/blu Free blu/blk blk/ora Free ora/blk blk/grn Free grn/blk blk/brn Free brn/blk blk/gry Free gry/blk yel/blu Free blu/yel P31003-H3560-S403-54-7620, 09/05 3-299 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 390: Tmdid8 (For U.s. Only)

    The circuits can be set up for immediate start or wink start. Switches and LEDs Trunk 3 Trunk 1 Trunk 4 Trunk 2 Trunk 7 Trunk 5 Trunk 8 Trunk 6 Figure 3-121 TMDID8 (for U.S. only) (S30810-Q2507-X) P31003-H3560-S403-54-7620, 09/05 3-300 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 391 TMDID8 (for U.S. only) - LED Statuses Status of LEDs 1–8 Meaning Channel is idle, ready to use Channel is seized Flashing Channel is deactivated Winking System software test in progress P31003-H3560-S403-54-7620, 09/05 3-301 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 392 Port 6 6 a/b-wire blu/red 6 b/a-wire red/ora Port 7 7 a/b-wire ora/red 7 b/a-wire red/grn Port 8 8 a/b-wire grn/red 8 b/a-wire No other wires used. P31003-H3560-S403-54-7620, 09/05 3-302 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 393: Tmew2

    Before you can start up a tie trunk, you must determine the type of interface supported by the two systems. Type 2 is preferable because it virtually excludes problems with longitudinal volt- ages. P31003-H3560-S403-54-7620, 09/05 3-303 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 394: Figure 3-122 Tmew2 - Front Panel (S30810-Q2292-X100)

    TMEW2 - Front Panel (S30810-Q2292-X100) To ensure sufficient shielding, provide the board with a shielding panel. For informa- > tion on mounting the shielding panel, see Section 4.2.5.2. P31003-H3560-S403-54-7620, 09/05 3-304 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 395: Table 3-144 Tmew2 - Led Statuses

    OK (idle state). Flashing At least one subscriber line circuit is activat- Cable and connector assignment For connecting to the SIVAPAC connector on the backplane: Table 3-145 ● P31003-H3560-S403-54-7620, 09/05 3-305 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 396: Table 3-145 Tmew2 - Sivapac Connector Assignment On The Backplane

    System ground, system battery grn/blk blk/brn Port 2 System ground, system battery brn/blk blk/gry Port 3 System ground, system battery gry/blk yel/blu Port 4 System ground, system battery blu/yel P31003-H3560-S403-54-7620, 09/05 3-306 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 397: Tmgl4 (For U.s. Only)

    Failure to follow these instructions may severely damage the system. Interfaces TMGL4 board CUP/ To trunks To ANI4 Figure 3-123 TMGL4 (For U.S. Only) - Interfaces (S30810-Q2918-X) P31003-H3560-S403-54-7620, 09/05 3-307 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 398 (tip), trunk 4 Note: Pinouts shown are at the board itself. The main distribution frame cable (MDF cable) sup- plied reverses the signal order before the MDF. P31003-H3560-S403-54-7620, 09/05 3-308 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 399: Tmgl4R (For U.s. Only)

    If ANI4R is installed as option 1 or 2, TMGL4R board must be inserted in slot 4, 6 or > 8 (slots 6 and 8 are not available with HiPath 3300). P31003-H3560-S403-54-7620, 09/05 3-309 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 400 (ring), trunk 2 a-wire (tip), trunk 2 b-wire (ring), trunk 3 a-wire (tip), trunk 3 b-wire (ring), trunk 4 a-wire (tip), trunk 4 – – Call charging module assignment (GMZ) P31003-H3560-S403-54-7620, 09/05 3-310 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 401: Tmgl8 (For U.s. Only)

    The TMGL8 board has an eight-path microswitch under a flip-up cover. The following settings apply for each channel: ON (right): Channel is enabled. ● OFF (left): Channel is disabled; no new seizures are permitted. ● P31003-H3560-S403-54-7620, 09/05 3-311 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 402 Port 6 6 a/b-wire blu/red 6 b/a-wire red/ora Port 7 7 a/b-wire ora/red 7 b/a-wire red/grn Port 8 8 a/b-wire grn/red 8 b/a-wire No other wires used. P31003-H3560-S403-54-7620, 09/05 3-312 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 403: Tml8W (Not For U.s.)

    (W300 to W650) to activate silent reversal. If silent reversal is inactive, users in the HiPath 3750 and HiPath 3700 would hear a busy signal following backward release instead of being released. P31003-H3560-S403-54-7620, 09/05 3-313 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 404: Table 3-150 Tml8W (Not For U.s.) - Led Statuses

    HiPath 3000 Manager E. not, replace board. Flashing Loadware is being loaded. Board test completed successfully. Board is OK (idle state). Flashing At least one circuit is activated. P31003-H3560-S403-54-7620, 09/05 3-314 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 405: Table 3-151 Tml8W (Not For U.s.) - Cable Assignment

    Port 8 grn/red red/brn Free brn/red red/gry Free gry/red blk/blu Free blu/blk blk/ora Free ora/blk blk/grn Free grn/blk blk/brn Free brn/blk blk/gry Free gry/blk yel/blu Free blu/yel P31003-H3560-S403-54-7620, 09/05 3-315 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 406: Tmq4 (For U.s. Only)

    AT&T 5Ess NI-1 ● AT&T 5ESS Custom ● Nortel DMS100 NI-1 ● Siemens EWSD NI-1 ● Interfaces TMQ4 board CUP/ To trunks Figure 3-127 TMQ4 (for U.S. only) (S30810-Q2917-X) P31003-H3560-S403-54-7620, 09/05 3-316 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 407 (tip), trunk 4 Note: Pinouts shown are at the board itself. The main distribution frame cable (MDF cable) sup- plied reverses the signal order before the MDF. P31003-H3560-S403-54-7620, 09/05 3-317 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 408: Tmst1 (For U.s. Only)

    TMST1 (for U.S. only) (S30810-Q2920-X) The lockout switch alerts the system software that the module will be removed so that no new calls are routed to the board. P31003-H3560-S403-54-7620, 09/05 3-318 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 409: Table 3-153 Tmst1 (For U.s. Only) - Led Statuses

    Flashing Loadware is being loaded. Board test completed successfully. Board is OK (idle state). Flashing At least one subscriber line circuit is activat- Board error Replace board. P31003-H3560-S403-54-7620, 09/05 3-319 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 410: Figure 3-129 Tmst1 Adapter (Sipac 1 Su - Mw8 (Rj48C)) C39228-A7195

    SU connector backplane TMST1 jack b-wire (ring), receive a-wire (tip), receive – – – b-wire (ring), transmit a-wire (tip), transmit – – – – – – – – – P31003-H3560-S403-54-7620, 09/05 3-320 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 411: Tms2 (Not For U.s.)

    H3 (red) Lockout switch S1 (position = free, factory default) X300 Jumper (setting = symm. line (120 ohms, X302 X301 factory default) Figure 3-130 TMS2 (Not for U.S) (S30810-Q2915-X) P31003-H3560-S403-54-7620, 09/05 3-321 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 412 SU connector Xx8B is used in board status 4 and lower, whereas SU connector Xx9 is used in board status 5 and higher. Note that the SU connector Xx9 was used in the old TMS2M board. > P31003-H3560-S403-54-7620, 09/05 3-322 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 413 H3 LED (see Figure 3-130): Reference clock display (clock is generated if this feature was ● configured using HiPath 3000 Manager E). – On: Reference clock for clock generator is created. – Off: No reference clock P31003-H3560-S403-54-7620, 09/05 3-323 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 414: Figure 3-131 S 2M Trunk Connection

    The delivery does not include a CABLU if the REAL board has been ordered or is already being used (the necessary CABLU is included in the delivery of the “ALUM using REAL” feature). P31003-H3560-S403-54-7620, 09/05 3-324 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 415: Figure 3-133 S 2M - Nt Connection (Not For U.s.)

    – Length: 6 (not in Germany), 10 and 20 m – Color code (see Table 3-155) The wires in a wire pair may be interchanged. Figure 3-133 - NT Connection (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-325 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 416: Figure 3-134 S 2M Connection To Deutsche Telekom Nt (For Germany Only)

    – Length: 6 (not in Germany), 10 and 20 m – Color code (see Table 3-155) The wires in a wire pair may be interchanged. Figure 3-134 Connection to Deutsche Telekom NT (For Germany Only) P31003-H3560-S403-54-7620, 09/05 3-326 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 417: Figure 3-135 S

    Fixed connection via public network (NT connection ac- cording to Figure 3-133) Cable S30267-Z57-Axxx 6 m (not Germany), 10 m and 20 m Figure 3-135 Networking Options (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-327 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 418: Tst1 (For U.s. Only)

    Rather than connecting to a main distribution frame (MDF), the TST1 connects to a channel service unit (CSU). The CSU supplies the required secondary protection. Interfaces To CO TST1 CUCR Figure 3-136 TST1 (For U.S. Only) (S30810-Q2919-X/S30810-K2919-Z) P31003-H3560-S403-54-7620, 09/05 3-328 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 419 TST1 (For U.S. Only) - Contact Assignment Contact Contact b-wire (ring), receive a-wire (tip), transmit a-wire (tip), receive not connected not connected not connected b-wire (ring), transmit not connected P31003-H3560-S403-54-7620, 09/05 3-329 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 420: Ts2 (Not For U.s.), Ts2R (Not For U.s.)

    ECG cabinet, for information on the connection and power supply. For HiPath 3000 V1.0 and later, you can also use the new TMCAS board to support country- specific CAS protocols. P31003-H3560-S403-54-7620, 09/05 3-330 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 421: Figure 3-137 Ts2 (Not For U.s.) - Interfaces (S30810-Q2913-X100, -X300)

    TS2 (Not for U.S.) - Interfaces (S30810-Q2913-X100, -X300) TS2R interfaces TS2R interface: CUCR MW8 (RJ48C) ● jack (MW line) Figure 3-138 TS2R (Not for U.S.) - Interfaces (S30810-K2913-Z100, -Z300) P31003-H3560-S403-54-7620, 09/05 3-331 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 422 Free Free b-wire (R), transmit a-wire (T), transmit An additional line must be provided from pins 1 and 2 on the X2 connector to NT1 for NT1 feeding. P31003-H3560-S403-54-7620, 09/05 3-332 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 423: Figure 3-139 S

    There is a power limit of < 15 W for this voltage, which the system feeds over the CUC. TS2R board ● The NT1 power supply must come from an S30122-X7321-X (S30122-X7321-X100 with UPS operation) power supply unit. P31003-H3560-S403-54-7620, 09/05 3-333 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 424: Figure 3-140 S 2M - Nt Connections For Spain And Portugal

    Cable 2 (2 units) = coaxial adapter cable, 30 cm: S30267-Z354-A3 TS2/TS2R upgrade kit for Portugal: L30252-U600-A190 ● containing the following: – Cable 3 (2 units) = Mini-coaxial cable, 10 cm: S30267-Z353-A1 P31003-H3560-S403-54-7620, 09/05 3-334 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 425: 4Sla (Not For U.s.), 8Sla, 16Sla (Not For U.s.)

    4SLA (Not for U.S.), 8SLA - Interfaces (S30810-Q2923-X200, -X100) Table 3-160 4SLA (Not for U.S.), 8SLA Contact Assignments Contact X2 (T/R ports 1 to 4) X3 (T/R ports 5 to 8) P31003-H3560-S403-54-7620, 09/05 3-335 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 426 The operating mode (short or long line with the appropriate flash times) can be set up for each subscriber line interface with HiPath 3000 Manager E (the menu settings: Set up station –> Sta- tion –> Param –> Flags). P31003-H3560-S403-54-7620, 09/05 3-336 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 427 ● Loop current detection > 10 mA ● Ground button detection > 20 mA ● The transmission method can be configured country-specifically by entering the country ● code. P31003-H3560-S403-54-7620, 09/05 3-337 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 428: 8Slar

    CUCR jacks) Port 8 Figure 3-143 8SLAR Interfaces (S30810-K2925-Z) Table 3-162 8SLAR Contact Assignments MW8 jack X2, pin T/R ports 1-4 MW8 Jack X2, pin T/R ports 5-8 P31003-H3560-S403-54-7620, 09/05 3-338 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 429 ● Loop current detection > 10 mA ● Ground button detection > 20 mA ● The transmission method can be configured country-specifically by entering the country ● code. P31003-H3560-S403-54-7620, 09/05 3-339 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 430: Options

    X6 KX-X relay interface System From analog trunks Pins 1-8 To analog trunk board To analog stations To central control or analog station board Pins 9-16 Figure 3-144 ALUM4 - Function P31003-H3560-S403-54-7620, 09/05 3-340 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 431: Figure 3-145 Alum4 - Interfaces (S30817-Q935-A)

    BT4 to TLA b – – TA1 to SLA* a – – TB1 to SLA* b – – TA2 to SLA* a – – TB2 to SLA* b P31003-H3560-S403-54-7620, 09/05 3-341 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 432 X3 and X4 before the MDF. To the analog station ports on the CBCC (recommended) or to four consecutive ports on an 8SLA board. P31003-H3560-S403-54-7620, 09/05 3-342 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 433 HiPath 3350 ALUM Relay Connector X6 K1-B K2-B BT1 (T1) Trunk board AT1 (R1) Station board K1-C K2-C Relay Connector Analog telephone Figure 3-146 ALUM4 - Basic Structure P31003-H3560-S403-54-7620, 09/05 3-343 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 434: Amom

    S30807-K5480- 1300 nm X300 mono mode Maximum optical attenuation in an AMOM to AMOM connection: a reserve of 4 dB attenuation must be included for ageing and splicing. P31003-H3560-S403-54-7620, 09/05 3-344 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 435 Data input on the optical fiber inter- Output face (front) Ground return path for the +5- Input/output V power supply +5 V +5-V power supply Input No other pins used. P31003-H3560-S403-54-7620, 09/05 3-345 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 436: Ani4 (For Selected Countries Only)

    E or optiPoint 500 phones ap- pears. This means that the ANI4 has received system software activation for all four channels. P31003-H3560-S403-54-7620, 09/05 3-346 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 437 FSK signal is sage is received. provided, but is not Bellcore- compliant on the customer side. This must be corrected by the service provider. Checksum is OK. – P31003-H3560-S403-54-7620, 09/05 3-347 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 438: Table 3-167 Ani4 (For Selected Countries Only) - Contact Assignments

    (ring), trunk 3 a-wire (tip), trunk 3 a-wire (tip), trunk 4 b-wire (ring), trunk 4 b-wire (ring), trunk 4 a-wire (tip), trunk 4 – – GMZ= Call charging module assignment P31003-H3560-S403-54-7620, 09/05 3-348 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 439: Figure 3-149 Ani4 (For Selected Countries Only) - Installation Steps

    Restart the system by reconnecting the power plug. Fig. 1 Fig. 2 Fig. 3 Pin 1 Pin 1 Figure 3-149 ANI4 (for selected countries only) - Installation Steps P31003-H3560-S403-54-7620, 09/05 3-349 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 440: Ani4R (For Selected Countries Only)

    8 (slots 6 and 8 not available with HiPath 3300). Interfaces To OPALR, or previous option TMGL4R X3 (10-pin MW10 jack) ANI4R Board side Figure 3-150 ANI4R (for selected countries only) (S30807-Q6917-Z103) P31003-H3560-S403-54-7620, 09/05 3-350 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 441 (ring), trunk 3 b-wire (ring), trunk 1 a-wire (tip), trunk 4 a-wire (tip), trunk 2 b-wire (ring), trunk 4 b-wire (ring), trunk 2 Call charging module assignment (GMZ) P31003-H3560-S403-54-7620, 09/05 3-351 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 442: Announcement And Music Modules

    (X19 and X20). MPPI (not S30122-K5380- Used in HiPath 3550 and HiPath 3350 (wall housing). ● for U.S.) X200 Connected via cable to X4 connector on CBCC/CBCP. ● P31003-H3560-S403-54-7620, 09/05 3-352 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 443 UAM (HiPath 3550 and HiPath 3350 only) is displayed as “Option 5”. The ALUM4 module cannot be displayed. Slot for EXM Cable duct Slot for EXM module Figure 3-151 EXM Slot for HiPath 3550 and HiPath 3350 Wall Housing P31003-H3560-S403-54-7620, 09/05 3-353 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 444 Boards for HiPath 3000 Options Connection of EXMR Front panel of the system EXMR Cinch jack (component side) Cable C39195-Z7001-C79 Figure 3-152 EXMR Connection to HiPath 3500 and HiPath 3300 P31003-H3560-S403-54-7620, 09/05 3-354 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 445: Evm

    Next set the number of mailboxes for autoconfiguration to "0". This prevents the user making ac- cidental changes to Call Management. P31003-H3560-S403-54-7620, 09/05 3-355 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 446: Figure 3-153 Evm (S30807-Q6945-X) - Interfaces

    Boards for HiPath 3000 Options Interfaces Spacing bolts 26-pin socket strip X1 (not used for HiPath 3000) Figure 3-153 EVM (S30807-Q6945-X) - Interfaces P31003-H3560-S403-54-7620, 09/05 3-356 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 447: Exmna (For U.s. Only)

    Figure 3-154 EXMNA (For U.S. Only) (S30807-Q6923-X) Cable duct Slot for EXMNA module Figure 3-155 EXMNA (for U.S. only) - Slot for HiPath 3550 and HiPath 3350 P31003-H3560-S403-54-7620, 09/05 3-357 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 448: Table 3-170 Exmna (For U.s. Only) - Contact Assignments

    EXMNA (for U.S. only) - Contact Assignments Contact Connector X1 Connector X2 Input Not assigned Input Not assigned Not assigned EXMCL Not assigned EXMDIR HRES EXMD EXMDET +5 V Not assigned P31003-H3560-S403-54-7620, 09/05 3-358 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 449: Gee8 (Not For U.s)

    Switch for setting the level per circuit On = – 24 dBm ● Off = – 10 dBm ● Switch on GEE8 On 1 Figure 3-156 GEE8 (Not for U.S.) (S30817-Q664-xxxx) P31003-H3560-S403-54-7620, 09/05 3-359 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 450: Gee12 (Nor For U.s.), Gee16 (Not For U.s.), Gee50 (Not For U.s.)

    The call charge detection channel is looped in the trunk and then routed to the TLA Interfaces CB side to the TLA GEE module To CO Board side Figure 3-157 GEE12, GEE16, GEE50 (Not for U.S.) - Interfaces (S30817-Q951-Axxx) P31003-H3560-S403-54-7620, 09/05 3-360 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 451: Table 3-172 Gee12, Gee16, Gee50 (Not For U.s.) - Contact Assignments

    CO 4 (AL4) CO 4 (BN 4) CO 4 (BL4) CO 4 (AN 4) – Call charging module as- – signment * for GEE 50 in France; otherwise free P31003-H3560-S403-54-7620, 09/05 3-361 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 452: Hope (For U.s. Only)

    The software load/diagnostic button is for software loads (for example, loading a specific ● language). The digital station connector connects the HOPE board to the corresponding digital ports, ● using a modular cable P31003-H3560-S403-54-7620, 09/05 3-362 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 453 ● Installation, servicing, and connectivity For information on installing, connecting, and servicing the HOPE board, refer to the Hicom Of- fice PhoneMail Entry Installation and System Administration Guide. P31003-H3560-S403-54-7620, 09/05 3-363 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 454: Opal And Opalr

    OPALR (Options Adapter Cable Long Rack) C39195-A7001-B142 (Figure 3-160) - for use ● in HiPath 3500 and HiPath 3300 (19-inch housing). OPAL interfaces Option board connection Ribbon cable folded and secured CBCC/CBCP interface Figure 3-159 OPAL (C39195-A7001-B130) P31003-H3560-S403-54-7620, 09/05 3-364 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 455: Figure 3-160 Opalr (C39195-A7001-B142)

    Boards for HiPath 3000 Options OPALR interface Option board connection CBRC interface Figure 3-160 OPALR (C39195-A7001-B142) P31003-H3560-S403-54-7620, 09/05 3-365 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 456: Pft1 (Not For U.s.), Pft4 (Not For U.s.)

    ALUM using PFT1/PFT4 TRUNK Trunk circuit Analog station board (optional) Analog telephone Figure 3-161 ALUM Using PFT1/PFT4 (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-366 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 457: Figure 3-162 Installation Location Of Pft1 And Pft4 (Mdfu/Mdfu-E)

    Figure 3-163. 2 x PFT1 1 x PFT4 System side Line network Figure 3-162 Installation Location of PFT1 and PFT4 (MDFU/MDFU-E) (Not for U.S.) P31003-H3560-S403-54-7620, 09/05 3-367 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 458 A, B = a, b (Telephone company) SMA, SMB = SLA board SLA, SLB = Analog telephone - 48 Figure 3-163 PFT1 (S30777-Q539-X) and PFT4 (S30777-Q540-X) Board Assignment P31003-H3560-S403-54-7620, 09/05 3-368 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 459: Real

    If the power supply voltage returns after an interruption and a trunk call is in progress, ac- tivation of the trunk failure transfer relay is prevented (by optocoupler). P31003-H3560-S403-54-7620, 09/05 3-369 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 460: Figure 3-164 Installation Location Of The Real Board

    It is connected to the MDFU or MDFU-E or the patch panel using an SU cable connector X06. UPSM REAL with connection cable Figure 3-164 Installation Location of the REAL Board P31003-H3560-S403-54-7620, 09/05 3-370 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 461 17 + 37 (GND = pins 27 + 48) 15 W if no REAL is available. MDFU Figure 3-165 REAL - Relay Contacts (De-Energized) and MDFU Interfaces P31003-H3560-S403-54-7620, 09/05 3-371 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 462 RK3, opener ora/blk AK3, closer blk/grn grn/blk blk/brn RK4, opener brn/blk AK4, closer blk/gry – 48 V (15 W max.) gry/blk – 48 V (15 W max.) yel/blu blu/yel P31003-H3560-S403-54-7620, 09/05 3-372 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 463: Reals

    Two –48-V lines fused using a PTC resistor are available for external applications. Signals are picked up via MDFU-E (Table 3-174: M48VF1 / 0V_F and M48VF2 / 0V_F). Each trunk has a maximum load capacity of 300 mA. P31003-H3560-S403-54-7620, 09/05 3-373 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 464: Figure 3-166 Reals (S30807-Q6629-X)

    Signals are picked up via SIVAPAC connec- tor X116 on the backplane. Removal tab You can insert a screwdriver here to remove REALS from the shelf. Figure 3-166 REALS (S30807-Q6629-X) P31003-H3560-S403-54-7620, 09/05 3-374 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 465: Figure 3-167 Reals Slots In The Basic Cabinet (With Outer Panel Mounted)

    REALS Slots in the Basic Cabinet (With Outer Panel Mounted) Cable and connector assignment Table 3-174 shows the assignment of the SIVAPAC connector X116 on the backplane and the assignment of the jumper strip in the MDFU-E. P31003-H3560-S403-54-7620, 09/05 3-375 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 466 PFTASa ALUM: Trunk board red/brn PFTASb brn/red PFTALa ALUM: Trunk red/gry PFTALb gry/red – blk/blu – blu/blk blk/ora – ora/blk – Relay 3: Normally blk/grn closed contact grn/blk P31003-H3560-S403-54-7620, 09/05 3-376 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 467: Table 3-174 Reals - Sivapac Connector Assignment On The Backplane

    Relay 1: Switch contact blu/vio Relay 2: Switch contact vio/ora Relay 3: Switch contact ora/vio Relay 4: Switch contact vio/grn grn/vio – vio/brn – brn/vio P31003-H3560-S403-54-7620, 09/05 3-377 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 468: Stbg4 (For France Only)

    AL 2 BL 2 BL 2 AN 2 AL 3 BL 3 BL 3 AN 3 AL 4 BL 4 BL 4 AN 4 – Not used – P31003-H3560-S403-54-7620, 09/05 3-378 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 469: Strb, Strbr

    For the manual relay on/off function and door opener, you must enter the desired switching time (expert mode code 26 2). P31003-H3560-S403-54-7620, 09/05 3-379 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 470 IEC 60950. Do not connect any circuits whose voltages exceed the following limit values: Maximum: 30 Vac (42 V ) or 60 Vdc. peak P31003-H3560-S403-54-7620, 09/05 3-380 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 471 K1.11 K1.12 K1.13 +12 V +12 VI Short the wires to activate the sensor. OPTKP1 Sensor To system Figure 3-171 STRB and STRBR Board Relay and Sensor Functions P31003-H3560-S403-54-7620, 09/05 3-381 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 472: Table 3-176 Strb Contact Assignments

    +12-V control voltage optocoupler K 4.11 Relay contact K4.1 (common) K 4.12 Relay contact K4.1 (NO) K 4.13 Relay contact K4.1 (NC) K 3.11 Relay contact K3.1 (common) P31003-H3560-S403-54-7620, 09/05 3-382 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 473 ACT1-1M Relay contact K200 (common) 1 ACT1-1B Relay contact K200 (NO) 1 ACT1-1A Relay contact K200 (NC) 1 P12VI + 12-V optocoupler 1 SENSE1 Control input optocoupler 1 P31003-H3560-S403-54-7620, 09/05 3-383 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 474: V24/1 (Not For U.s.)

    To CBCC/CBCP (X7) via ribbon cable Component side shown 25-pin Sub-D jack Figure 3-172 V24/1 (Not for U.S.) (S30807-Q6916-X100) Figure 3-173 HiPath 3550 and HiPath 3350 - V.24 Connections P31003-H3560-S403-54-7620, 09/05 3-384 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 475 V.24 (RS-232) Connector Assignment, HiPath 3550 and HiPath 3350 Table 3-178 Pin Assignments of the V.24 Socket X2 Connector X2 Signal 12000 - 12100 No other pins in connector X2 are used. P31003-H3560-S403-54-7620, 09/05 3-385 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 476: V.24 Adapter

    (C39195-Z7267-C13) and a 9-pin jack for connection to the V.24 interface on all HiPath 3000 V1.2 (or later) systems. V.24 adapter assignment Table 3-179 V.24 Adapter Assignment (C39334-Z7080-C2) 9-pin jack Signal 25-pin jack P31003-H3560-S403-54-7620, 09/05 3-386 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 477: V.24 Cable

    Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Data Send Ready Request To Send Clear To Send Ground Ring Indicator Shield Figure 3-175 V.24 Cable Assignment (C30267-Z355-A25) P31003-H3560-S403-54-7620, 09/05 3-387 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 478 Boards for HiPath 3000 Options P31003-H3560-S403-54-7620, 09/05 3-388 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 479: Installing Hipath 3000

    Performing a Visual Inspection, page 4-164 ● Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, page 4-165 Installation Prerequisites, page 4-165 ● Installation Procedure, page 4-166 ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 480 Installing HiPath 3000 Overview Topic Installing HiPath 3550 and HiPath 3350, page 4-167 ● Installing HiPath 3500 and HiPath 3300 (19-Inch Housing), page 4-188 ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 481 Telephone test set for analog interfaces – Not for U.S.: ISDN tester (such as K3000 or Aurora) Duet Expert, Remote – For U.S. only: Aurora , Aurora Aurora or similar, ISDN protocol analyzer P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 482: Installing Hipath 3800

    Loading the System Software and Installing Subboards on the CBSAP, page 4-81 Connecting Workpoint Clients, page 4-82 Making Trunk and Networking Connections, page 4-82 Performing a Visual Inspection, page 4-83 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 483: Installing Hipath 3800 (Standalone)

    Ensure the availability of a power source that meets the requirements described in ● Section 4.2.3.1.1. Ensure that Siemens equipment is 40 in. (101.6 cm) from other electrical equipment. The ● National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical equipment and 40 in.
  • Page 484: For U.s. Only: Ac Outlet

    A warning should be attached to the circuit breaker to prevent accidental removal of power. ● An independent electric circuit with an isolated ground conductor should be used. ● The system must be properly grounded before startup (see description in Section 4.2.3.4). P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 485: Unpacking The Components

    Determine whether any damage has occurred during transport and report it to the proper departments. Dispose of the packing materials properly. Caution Only use tools and equipment that are in perfect condition. Do not use equipment with visible damage. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 486: Setting Up The System Cabinets

    4.2.3.3.1 Overview System configurations The following setup options are possible for system cabinets: Single cabinet ● Two cabinets (stacked) ● Two cabinets (side by side) ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 487: Setting Up A Single Cabinet

    Fix the cabinet foot in position by tightening the lock nut (Figure 4-1, A). ● Basic cabinet setup ≥ 50 mm Figure 4-1 HiPath 3800 - Setting Up the Basic Cabinet P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 488: Stacking Two Cabinets

    Check that the space between the base of the basic cabinet and the ground is at least 50 mm. If necessary, set up the expansion cabinet as described in Step 3. P31003-H3560-S403-54-7620, 09/05 4-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 489: Figure 4-2 Hipath 3800 - Positioning The Cabinet Feet

    Installing HiPath 3000 Installing HiPath 3800 Positioning the cabinet feet Figure 4-2 HiPath 3800 - Positioning the Cabinet Feet P31003-H3560-S403-54-7620, 09/05 4-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 490: Figure 4-3 Hipath 3800 - Installing A Stacked Two-Cabinet System

    Installing HiPath 3000 Installing HiPath 3800 Installing a stacked two-cabinet system ≥ 50 mm ≥ 50 mm Figure 4-3 HiPath 3800 - Installing a Stacked Two-Cabinet System (Rear View) P31003-H3560-S403-54-7620, 09/05 4-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 491: Setting Up A Two-Cabinet System Side By Side

    Check that the space between the base of the expansion cabinet and the ground is at least 50 mm. If necessary, set up the expansion cabinet as described in Step 3 ensuring that both cabinets are at exactly the same level. P31003-H3560-S403-54-7620, 09/05 4-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 492 Installing HiPath 3000 Installing HiPath 3800 Installing a Two-Cabinet System Side by Side ≥ 50 mm Figure 4-4 HiPath 3800 - Installing a Two-Cabinet System Side by Side (Rear View) P31003-H3560-S403-54-7620, 09/05 4-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 493: Grounding The System

    If the building floor plan does not permit this, you may need a line driver to isolate the external devices in the event of a malfunction. P31003-H3560-S403-54-7620, 09/05 4-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 494 - central heating system - drain channels - ground conductor for antenna system Figure 4-5 HiPath 3800 - Grounding the System Cabinets and Main Distribution Frame (nor for U.S.) P31003-H3560-S403-54-7620, 09/05 4-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 495 L1 N PE Grounding outlets 230 V ~ HiPath 3800 Example Connector Main grounding socket terminal green/yellow Figure 4-7 HiPath 3800 - Grounding Option 1b (not for USA) P31003-H3560-S403-54-7620, 09/05 4-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 496: For U.s. Only: Grounding The System

    The minimum cross-section required is 12 AWG. Figure 4-8 shows the safety conductor connectors for the basic cabinet. An expansion cabinet requires a separate earth ground. P31003-H3560-S403-54-7620, 09/05 4-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 497: Figure 4-8 Hipath 3800 - Earth Ground Connection (For U.s. Only)

    Figure 4-8 HiPath 3800 - Earth ground connection (for U.S. only) Grounding the Main Distribution Frame Mount and ground the MDF in accordance with the manufacturer’s instructions. P31003-H3560-S403-54-7620, 09/05 4-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 498: Checking The Grounding

    < 1 ohm tem parts (basic cabinet, expansion cabinet, main distri- bution frame). Prerequisite: HiPath 3800 is not yet connected to the low-voltage net- work via the power cable. P31003-H3560-S403-54-7620, 09/05 4-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 499: Installing Hipath 3800 (19-Inch Cabinet)

    If inactive components (e.g. patch panel) are involved, the basic cabinet can also be installed above them. P31003-H3560-S403-54-7620, 09/05 4-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 500: Figure 4-9 Hipath 3800 - System Cabinet With Plastic Cover

    Systems covered with condensation must be dried before being used. Observe the environmental conditions specified in Section 2.11. ● Information on the design of the HiPath 3800 can be found in Section 2.2.2.1. P31003-H3560-S403-54-7620, 09/05 4-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 501: Figure 4-10 Hipath 3800 - Installation Examples In The 19-Inch Cabinet

    Examples of a 19-inch cabinet height of 1.92 m with 37 height units Patch Panel HiPath 3800 Expansion cabi- Patch Panel HiPath 3800 HiPath 3800 Basic cabinet Basic cabinet Figure 4-10 HiPath 3800 - Installation Examples in the 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 502: For U.s. Only: Ac Outlet

    Determine whether any damage has occurred during transport and report it to the proper departments. Dispose of the packing materials properly. Caution Only use tools and equipment that are in perfect condition. Do not use equipment with visible damage. P31003-H3560-S403-54-7620, 09/05 4-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 503: Mounting System Cabinets In The 19-Inch Cabinet

    ● stacked system cabinets. A minimum clearance of one free height unit above a system cabinet is sufficient if a patch panel is to be installed, for example. P31003-H3560-S403-54-7620, 09/05 4-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 504: Figure 4-11 Hipath 3800 - Removing Cabinet Feet

    Repeat steps 1 to 5 if you want to install an expansion cabinet. Figure 4-11 HiPath 3800 - Removing Cabinet Feet P31003-H3560-S403-54-7620, 09/05 4-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 505: Figure 4-12 Hipath 3800 - Installing System Cabinets In 19-Inch Cabinet

    Installing HiPath 3000 Installing HiPath 3800 Installation in the 19-inch cabinet Figure 4-12 HiPath 3800 - Installing System Cabinets in 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 506: Grounding The System

    The 19-inch cabinet’s potential equalization bus may only be used if it is grounded by a separate ground conductor. Failure to follow these instructions can result in electrical shock. P31003-H3560-S403-54-7620, 09/05 4-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 507 Min. cross-section ≥ 2.5 mm Min. cross-section ≥ 2.5 mm Potential equalization bus, in 19" cabinet for example Figure 4-13 HiPath 3800- Grounding the Systems and Patch Panels in a 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 508: Checking The Grounding

    < 1 ohm tem parts (basic cabinet, expansion cabinet, patch pan- el). Prerequisite: HiPath 3800 is not yet connected to the low-voltage net- work via the power cable. P31003-H3560-S403-54-7620, 09/05 4-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 509: Installing Boards (Configuration Notes)

    Depending on your requirements, up to three LUNA2 power supply units can be used in the basic cabinet BC and up to four in the expansion cabinet EC. In V6.0 or later, the cPCI box CSAPE can be used in the basic cabinet. P31003-H3560-S403-54-7620, 09/05 4-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 510: Figure 4-14 Hipath 3800 - Board Slots In The Basic Cabinet

    Installing HiPath 3000 Installing HiPath 3800 Figure 4-14 HiPath 3800 - Board Slots in the Basic Cabinet P31003-H3560-S403-54-7620, 09/05 4-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 511: Figure 4-15 Hipath 3800 - Board Slots In The Expansion Cabinet

    Installing HiPath 3000 Installing HiPath 3800 Figure 4-15 HiPath 3800 - Board Slots in the Expansion Cabinet P31003-H3560-S403-54-7620, 09/05 4-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 512: Inserting Or Removing Boards

    Insert the tip of the board wrench marked “Plug In” into the bottom opening in the front cover of the board. Lever the board into the shelf of the cabinet by pushing the board wrench up- wards (Figure 4-16, right). P31003-H3560-S403-54-7620, 09/05 4-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 513: Figure 4-16 Hipath 3800 - Removing/Inserting The Board Using The Board

    Then push the shielding cover in the direction of the board until it locks into position (refer to Figure 4-17). Empty board slots must also be covered with shielding covers. Figure 4-17 Installing the Board Shielding Cover P31003-H3560-S403-54-7620, 09/05 4-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 514 (see Figure 4-18). Fixing screws Fixing screws Figure 4-18 HiPath 3800 - cPCI Box CSAPE in the Basic Cabinet with Panel Mounted P31003-H3560-S403-54-7620, 09/05 4-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 515: Figure 4-19 Hipath 3800 - Installing The Luna2 Power Supply Unit

    The slots for the power supply units must be covered with an outer panel before the system is started up. The outer panel is fixed onto the shelf with screws (see Figure 4-20 and Figure 4-21). P31003-H3560-S403-54-7620, 09/05 4-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 516: Figure 4-20 Hipath 3800 - Slots For Luna2 And Reals In The Basic Cabinet

    HiPath 3800 - Slots for LUNA2 and REALS in the Basic Cabinet (With Out- er Panel Mounted) Fixing screws Figure 4-21 HiPath 3800 - Slots for LUNA2 in the Expansion Cabinet (With Outer Panel Mounted) P31003-H3560-S403-54-7620, 09/05 4-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 517: Figure 4-22 Hipath 3800 - Installing The Reals Board

    The slots for the power supply units and for the REALS board must be covered with an out- er panel before the system is started up. The outer panel is fixed onto the shelf with screws (see Figure 4-20). P31003-H3560-S403-54-7620, 09/05 4-39 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 518: Mounting Connector Panels (If Required)

    SLMO2 Section 4.2.6.6) SLMO8 STMD3 TM2LP TMC16 TMDID different or no as- Use filler panels to cover the backplane sections of signment other boards and empty board slots. P31003-H3560-S403-54-7620, 09/05 4-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 519 TMDID different or no as- Use filler panels to cover the backplane sections of signment other boards and empty board slots. for selected countries only for U.S. only P31003-H3560-S403-54-7620, 09/05 4-41 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 520: Installing The Sivapac-Sipac Board Adapter

    The SIVAPAC-SIPAC board adapter consists of three individual parts (refer to Figure 4-23): two adapter modules ● one startup module ● Adapter modules Startup module Component side board Figure 4-23 SIVAPAC-SIPAC Board Adapter P31003-H3560-S403-54-7620, 09/05 4-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 521: Figure 4-24 Installing The Sivapac-Sipac Board Adapter

    Repeat steps 2 to 5 to install the second adapter module. Plug the startup module (Figure 4-24, C,) into the hotplug connector on the board. Figure 4-24 Installing the SIVAPAC-SIPAC Board Adapter P31003-H3560-S403-54-7620, 09/05 4-43 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 522 Remove the black lock (At the point marked with the arrow press the lock out of its seating and pull it out of the shelf.) Figure 4-25 Replacing the Board Lock P31003-H3560-S403-54-7620, 09/05 4-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 523: Initializing The Boards

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 Basic cabinet 1 2 3 4 5 6 7 8 9 10 Figure 4-26 HiPath 3800 - Initialization of Subscriber Line Circuits and Ports P31003-H3560-S403-54-7620, 09/05 4-45 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 524: Distribution Of The Pcm Highway

    With the exception of boards DIUN2, DIU2U (for U.S. only) and STMI2, the peripheral boards only use the PCM highways of bundle A: – PCM segment for board slots 1 – 5 = 128 time-division multiplex channels (four PCM highways) P31003-H3560-S403-54-7620, 09/05 4-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 525: Figure 4-28 Hipath 3800 - Pcm Highways In The Expansion Cabinet

    PCM segment for board slots 1 – 6 = 128 time-division multiplex channels (four PCM high- ● ways) PCM segment for board slots 8 – 14 = 128 time-division multiplex channels (four PCM high- ● ways) PCM highway bundle F is not used. P31003-H3560-S403-54-7620, 09/05 4-47 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 526 Board Maximum number of time-division Time-division multiplex multiplex channels required channel assignment DIU2U static DIUN2 static IVMN8 dynamic IVMNL dynamic SLCN dynamic SLMA dynamic SLMA8 dynamic SLMO2 dynamic P31003-H3560-S403-54-7620, 09/05 4-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 527 The maximum number of masters and slaves possible is taken into consideration. Static time-division multiplex channel assignment for operation as a trunk board, dynamic assignment for operation as a subscriber line module. PDMX is not currently released. P31003-H3560-S403-54-7620, 09/05 4-49 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 528: Static Traffic Capacity

    1 – 5 and for slots 7 – 10 for these boards in the basic cabinet. If HiPath 3800 is used as a two-cabinet system, a use of PCM highway bundle F is not possible. P31003-H3560-S403-54-7620, 09/05 4-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 529: Connecting The Cable To The Backplane

    The system may only be started (connected to the power supply) if all system cabi- nets are sealed at the rear with the connection and filler panels provided. P31003-H3560-S403-54-7620, 09/05 4-51 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 530: Backplane Of The Basic Cabinet

    Backplane of the Basic Cabinet 9 SIVAPAC connec- tor for peripherals 68-pin DB68 mini- jack (connection to Figure 4-29 HiPath 3800 - Backplane (S30804-Q5392-X) of the Basic Cabinet P31003-H3560-S403-54-7620, 09/05 4-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 531: Figure 4-30 Hipath 3800 - Connectors And Jacks On The Backplane Of The

    Installing HiPath 3000 Installing HiPath 3800 X214 X211 Figure 4-30 HiPath 3800 - Connectors and Jacks on the Backplane of the Basic Cabinet P31003-H3560-S403-54-7620, 09/05 4-53 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 532 68-pin DB68 mini-jack for connecting the cable C39195-Z7611-A10 to the ex- pansion cabinet (for the DBSAP board) X209 DC port X211, X212 AC power X214 10-pin connection for the ring generator RGMOD (for selected countries only) P31003-H3560-S403-54-7620, 09/05 4-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 533: Expansion Cabinet Backplane

    Installing HiPath 3000 Installing HiPath 3800 4.2.6.2 Expansion Cabinet Backplane Figure 4-31 HiPath 3800 - Expansion Cabinet Backplane (S30804-Q5393-X) P31003-H3560-S403-54-7620, 09/05 4-55 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 534: Figure 4-32 Hipath 3800 - Connectors And Jacks On The Backplane Of The

    Installing HiPath 3000 Installing HiPath 3800 X214 Figure 4-32 HiPath 3800 - Connectors and Jacks on the Backplane of the Expansion Cab- inet P31003-H3560-S403-54-7620, 09/05 4-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 535: Connecting Cables Between The Basic And Expansion Cabinet

    Basic cabinet = X201 jack ● Expansion cabinet = DBSAP board ● To ensure smooth operation, use only shielded cables with a maximum length of > 1 m. P31003-H3560-S403-54-7620, 09/05 4-57 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 536: Connecting Peripherals To The Sivapac Connector On The Backplane

    S30267-Z196-A150: 15 m in length ● S30267-Z196-A250: 25 m in length ● S30267-Z196-A350: 35 m in length ● S30267-Z196-A550: 55 m in length ● S30267-Z196-A950: 95 m in length ● P31003-H3560-S403-54-7620, 09/05 4-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 537 After the cable has been connected, the backplane of the basic cabinet and that of > the expansion cabinet (if applicable) must be closed with the dummy panels provid- ed (C39165-A7075-C44). P31003-H3560-S403-54-7620, 09/05 4-59 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 538: Figure 4-33 Hipath 3800 - Backplane Of The Basic Cabinet With Mounted Filler

    Installing HiPath 3000 Installing HiPath 3800 Figure 4-33 HiPath 3800 - Backplane of the Basic Cabinet with Mounted Filler Panels P31003-H3560-S403-54-7620, 09/05 4-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 539: Connecting Peripherals To The Connector Panels With Rj45 Jacks

    STMD3 The RJ45 jacks are configured with four wires. S stations can be directly connected (1:1 cable). The receive and send lines should be switched for trunk connections. P31003-H3560-S403-54-7620, 09/05 4-61 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 540 The backplane sections of other boards and empty board slots must be cov- assignment ered with filler panels. for selected countries only for U.S. only Information on cable and connector assignment is provided in the board descriptions in Chapter 3. P31003-H3560-S403-54-7620, 09/05 4-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 541: For U.s. Only: Connecting Peripherals To The Connector Panels With

    No assignment The backplane sections with empty board slots must be covered with filler panels. Information on cable and connector assignment is provided in the board descriptions in Chapter 3. P31003-H3560-S403-54-7620, 09/05 4-63 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 542: Connecting Peripherals To The Connector Panels With Sipac 1 Su

    MDFU-E or an external patch panel. See also Section 4.2.7, “Using an External Main Distribu- tion Frame or External Patch Panel”. In special cases where the prefabricated CABLUs cannot be used, open-end cables should be used. P31003-H3560-S403-54-7620, 09/05 4-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 543 The backplane sections of other boards and empty board slots must be cov- assignment ered with filler panels. for selected countries only for U.S. only Information on cable and connector assignment is provided in the board descriptions in Chapter 3. P31003-H3560-S403-54-7620, 09/05 4-65 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 544: Using An External Main Distribution Frame Or External Patch Panel

    Main distribution frame MDFU-E, Section 4.2.7.1 ● Patch panel S30807-K6143-X, Section 4.2.7.2 ● patch panel C39104-Z7001-B3, Section 4.2.7.3 ● For U.S. only: Connecting Network Facilities, Section 4.2.7.4 ● P31003-H3560-S403-54-7620, 09/05 4-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 545: Using An External Main Distribution Frame Mdfu-E S30805-U5283-X

    MDFU-E - Layout and Dimensions (669.0 x 328.8 x 125.4 mm) Not more than 21 CABLUs per MDFU-E with one 16-TW strip or 25-TW strip (9 x 30 mm) can be implemented. P31003-H3560-S403-54-7620, 09/05 4-67 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 546: Mounting The Main Distribution Frame (Mdfu-E)

    (outside stations) ● lines > 500 m long. ● Connect the polarized surge protectors to the plugging locations on the splitting strip described above (see Figure 4-39). P31003-H3560-S403-54-7620, 09/05 4-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 547: Figure 4-38 Assignment (Numbering) Of The Splitting/Jumper Strips

    1 ... Splitting strip for 16 TW (C39334-A166-A1) No. 25 not used Jumper strip for 25 TW (C39334-A166-A3) Figure 4-38 Assignment (Numbering) of the Splitting/Jumper Strips (view from above) P31003-H3560-S403-54-7620, 09/05 4-69 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 548 Stripped length = 910 ± 5 mm for MDFU-E slots 1 to 10 Velcro tape (19 mm wide) Bundle fastener Figure 4-39 Stripping an Open-End Cable for the MDFU-E P31003-H3560-S403-54-7620, 09/05 4-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 549 Note: In the case of cables with 16 double wires, the specifications for pairs 17 to 24 are gry/red not relevant. blk/blu blu/blk blk/ora ora/blk blk/grn grn/blk blk/brn brn/blk blk/gry gry/blk P31003-H3560-S403-54-7620, 09/05 4-71 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 550: Inserting The External Patch Panel S30807K6143-X

    MW8 jack assignment: 4 = a-wire 5 = b-wire Necessary height units for 19-inch cabinet assembly: 1 (one height unit corresponds to approx. 1.7’’=43 mm) Figure 4-40 Patch Panel S30807-K6143-X P31003-H3560-S403-54-7620, 09/05 4-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 551: Installing The Patch Panel In A 19-Inch Cabinet

    Insert the patch panel (A, in Figure 4-41) above the system cabinet and secure it to the 19-inch frame on both the left and the right using two screws on each side. Figure 4-41 Installing the External Patch Panel in the 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-73 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 552: Connecting The Line Network To The External Patch Panel

    Board with 16 ports Board with 24 ports Example 3 Board with 16 ports Board with 24 ports Figure 4-42 Layout of the Patch Panel S30807-K6143-X for Different Peripheral Boards P31003-H3560-S403-54-7620, 09/05 4-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 553 Direct connector jumpering on the X12/X13 connector. Bridges are not necessary in ● this case. X12, X14 X13, X15 Figure 4-43 Assignment of Patch Panel S30807-K6143-X P31003-H3560-S403-54-7620, 09/05 4-75 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 554: Inserting External S

    All incoming cables must be attached to the patch panel using cable ties. > 3 x 8 MW8 jacks Necessary height units for 19-inch cabinet assembly: 1 (one height unit corresponds to approx. 1.7’’=43 mm) Figure 4-44 Patch Panel C39104-Z7001-B3 P31003-H3560-S403-54-7620, 09/05 4-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 555: Installing The S

    (B) on each side. Figure 4-45 Installing the External S Patch Panel in the 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-77 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 556: Connecting Lines To The External S Patch Panel

    8 7 6 3 2 1 4 5 Pin assignment of MW8 jacks Twist the wire pairs before laying them. Figure 4-47 Laying Wire Pairs at the S Patch Panel P31003-H3560-S403-54-7620, 09/05 4-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 557 Stripped length = 600 mm ± 5 mm Figure 4-48 Stripping the Open-End Cable for the S Patch Panel The color codes for open-end cables are provided in Table 4-8. P31003-H3560-S403-54-7620, 09/05 4-79 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 558: For U.s. Only: Connecting Network Facilities

    SLMA / SLMA8 ● TMC16 ● TMDID ● TMEW2 ● TM2LP ● * When this module is connected to the public network, secondary protection must be provided by the CSU. P31003-H3560-S403-54-7620, 09/05 4-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 559: Loading The System Software And Installing Subboards On The Cbsap

    Place the central control board on a flat surface before installing subboards. The spacing bolts supplied guarantee the correct insertion of the subboard, so you should always mount them (see Figure 3-6). Otherwise you may damage the board. P31003-H3560-S403-54-7620, 09/05 4-81 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 560: Connecting Workpoint Clients

    STMD3 (S ● STMI2 (IP) ● TM2LP (MSI) ● TMEW2 (E&M) ● DIU2U (For U.S. Only) ● TMC16 (for selected countries only) ● TMDID (for U.S. only) ● P31003-H3560-S403-54-7620, 09/05 4-82 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 561: Performing A Visual Inspection

    Check whether all system Get additional connection and filler cabinets have been sealed panels where required. at the rear with the connec- tion and filler panels provid- P31003-H3560-S403-54-7620, 09/05 4-83 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 562 After finishing the visual inspection, you can begin starting up the HiPath 3800 as > described in Chapter 5. P31003-H3560-S403-54-7620, 09/05 4-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 563: Installing Hipath 3750, Hipath 3700

    Telephone test set for analog interfaces – Not for U.S.: ISDN tester (such as K3000 or Aurora) Duet Expert, Remote – For U.S. only: Aurora , Aurora Aurora or similar, ISDN protocol analyzer P31003-H3560-S403-54-7620, 09/05 4-85 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 564: Installation Procedure

    Loading the System Software and Installing Subboards on the CBCPR, page 4-153 Configuration notes, page 4-154 (cabinet(s) are already equipped with the boards) Connecting Workpoint Clients, page 4-163 P31003-H3560-S403-54-7620, 09/05 4-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 565 HiPath 3750, HiPath 3700 - System Installation Procedure Step Installation Activity Installing HiPath 3750 Installing HiPath 3700 (19-Inch Cabi- net) Making trunk connections, page 4-163 Performing a Visual Inspection, page 4-164 P31003-H3560-S403-54-7620, 09/05 4-87 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 566 ● board configuration ● final visual inspection ● applies to both HiPath 3750 and HiPath 3700 and is described starting in Section 4.3.5. P31003-H3560-S403-54-7620, 09/05 4-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 567: Selecting The Installation Site

    Ensure the availability of a power source that meets the requirements described in ● Section 4.3.3.1.1. Ensure that Siemens equipment is 40 in. (101.6 cm) from other electrical equipment. The ● National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical equipment and 40 in.
  • Page 568: For U.s. Only: Ac Outlet

    A warning should be attached to the circuit breaker to prevent accidental removal of power. ● An independent electric circuit with an isolated ground conductor should be used. ● The system must be properly grounded before startup (see description in Section 4.3.3.5). P31003-H3560-S403-54-7620, 09/05 4-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 569: Unpacking The Components

    Determine whether any damage has occurred during transport and report it to the proper departments. Dispose of the packing materials properly. Caution Only use tools and equipment that are in perfect condition. Do not use equipment with visible damage. P31003-H3560-S403-54-7620, 09/05 4-91 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 570: Install Mdfu Or Mdfu-E (Not For Usa)

    Insert the wall anchors and screw in the screws, leaving 5 mm projecting. Remove the housing cover. Attach the main distributor frame to the brackets and remove the packing protection covering. Tighten the screws through the holes. P31003-H3560-S403-54-7620, 09/05 4-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 571: Setting Up The System Cabinets

    Two cabinets stacked on a horizontal surface Two cabinets stacked on a wall (for U.S. only) Two cabinets side-by-side on a horizontal surface Three cabinets on a horizontal surface (two stacked) P31003-H3560-S403-54-7620, 09/05 4-93 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 572: Removing The Cabinet Covers

    Then insert the screwdriver in the second recess (3), loosen its snap fastener. Mounting the cover Cabinet Figure 4-49 HiPath 3750 - Removing the Front and Rear Covers P31003-H3560-S403-54-7620, 09/05 4-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 573: Setting Up A Single Cabinet

    Keyed holes Latch Swing-out component Figure 4-50 HiPath 3750 - Wall-Mount Kit (for U.S. only) Procedure Step Activity Install a plywood backboard at least 0.75 in. (19.05 mm) thick. P31003-H3560-S403-54-7620, 09/05 4-95 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 574: Figure 4-51 Hipath 3750 Mounting A One-Cabinet System On The Wall

    Do not fasten power cords to building surfaces when mounting cabinets on the wall. Wall Mounting (One-Cabinet System) Figure 4-51 HiPath 3750 Mounting a One-Cabinet System on the Wall (for U.S. only) P31003-H3560-S403-54-7620, 09/05 4-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 575: Stacking Two Cabinets

    Take note that the bolts and inserts included in the seismic anchor kit are designed for concrete floors. Bolts for other surfaces must be requested or supplied separate- P31003-H3560-S403-54-7620, 09/05 4-97 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 576 EC1 and the top of the BC with a pair of diagonal cutting pliers and break them out with a pair of flat-nosed pliers. Caution Be careful when breaking out the recesses. Remove any sharp edges and corners. P31003-H3560-S403-54-7620, 09/05 4-98 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 577: Figure 4-53 Hipath 3750 - Mounting The Stabilizer Feet

    Continue installing the system. Mounting the stabilizer feet Figure 4-53 HiPath 3750 - Mounting the Stabilizer Feet (Three-Cabinet System Shown) P31003-H3560-S403-54-7620, 09/05 4-99 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 578: For U.s. Only: Mounting Two Cabinets Stacked On The Wall

    Use the keyed holes in the top of the bracket and the round hole in the bottom of the bracket. Install the screws in the top two holes for each bracket, tightening them until 0.25 in. (6.35 mm) is protruding. P31003-H3560-S403-54-7620, 09/05 4-100 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 579: Figure 4-55 Hipath 3750 Wall Mounting For A Stacked Two-Cabinet System

    Do not fasten power cords to building surfaces when mounting cabinets on the wall. Wall Mounting (Stacked Two-cabinet System) Figure 4-55 HiPath 3750 Wall Mounting for a Stacked Two-Cabinet System (for U.S. only) P31003-H3560-S403-54-7620, 09/05 4-101 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 580 EC1 and the top of the BC with a pair of diagonal cutting pliers and break them out with a pair of flat-nosed pliers. Warning Be careful when breaking out the recesses. Remove any sharp edges and corners. P31003-H3560-S403-54-7620, 09/05 4-102 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 581: Setting Up A Two-Cabinet System Side By Side

    HiPath 3750 - Installing a Two-Cabinet System (Side By Side) Laying the Connecting Cables To lay the connection cables between the cabinets, first remove the lower grills in the rear cov- ers. P31003-H3560-S403-54-7620, 09/05 4-103 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 582: Setting Up A Stacked Three-Cabinet System

    Take note that the bolts and inserts included in the seismic anchor kit are designed for concrete floors. Bolts for other surfaces must be requested or supplied separate- P31003-H3560-S403-54-7620, 09/05 4-104 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 583: Figure 4-57 Hipath 3750 - Installing A Three-Cabinet System (Stacked)

    EC1 and the top of the BC with a pair of diagonal cutting pliers and break them out with a pair of flat-nosed pliers. Caution Be careful when breaking out the recesses. Remove any sharp edges and corners. P31003-H3560-S403-54-7620, 09/05 4-105 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 584: For U.s. Only: Installing The Seismic Anchors

    The anchor for the back of the cabinets is wider to provide space for cables. Seismic Anchoring Front Back Figure 4-58 HiPath 3750 Seismic Anchors (for U.S. only) P31003-H3560-S403-54-7620, 09/05 4-106 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 585: Figure 4-59 Hipath 3750 Seismic Anchoring For Multiple Cabinets

    Installing HiPath 3000 Installing HiPath 3750, HiPath 3700 Seismic Anchors for Multiple Cabinets Figure 4-59 HiPath 3750 Seismic Anchoring for Multiple Cabinets (Front View) (for U.S. only) P31003-H3560-S403-54-7620, 09/05 4-107 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 586: Grounding The System

    If the building floor plan does not permit this, you may need a line driver to isolate the external devices in the event of a malfunction. P31003-H3560-S403-54-7620, 09/05 4-108 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 587 - central heating system - drain channels - ground conductor for antenna system Figure 4-60 HiPath 3750 - Grounding the System Cabinets and Main Distribution Frame (not for U.S.) P31003-H3560-S403-54-7620, 09/05 4-109 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 588 Grounding option 1b L1 N PE Grounding outlets 230 V ~ HiPath 3750 Example Connector socket green/yellow Figure 4-62 HiPath 3750 - Grounding Option 1b (not for USA) P31003-H3560-S403-54-7620, 09/05 4-110 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 589: For U.s. Only: Grounding The System

    If two system cabinets are mounted on the wall, a separate grounding connector is also re- quired for the expansion cabinet. Do not use the metal connecting plates on wall-mounted sys- tems. P31003-H3560-S403-54-7620, 09/05 4-111 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 590: Figure 4-63 Hipath 3750 - Grounding Connector For Basic Cabinet

    Figure 4-63 HiPath 3750 - Grounding connector for Basic Cabinet (for U.S. only) Grounding the Main Distribution Frame Mount and ground the MDF in accordance with the manufacturer’s instructions. P31003-H3560-S403-54-7620, 09/05 4-112 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 591: Checking The Grounding

    < 1 ohm tem parts (basic cabinet, expansion cabinets, main dis- tribution frame). Prerequisite: HiPath 3750 is not yet connected to the low-voltage net- work via the power cable. P31003-H3560-S403-54-7620, 09/05 4-113 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 592: Connecting The Cable To The Backplane

    The “8-slot” basic cabinet has seven slots, while the expansion cabinets each have > eight slots for peripheral boards. Backplane on the “8-slot” basic cabinet CBCPR UPSM REAL only) Figure 4-64 HiPath 3750 - Backplane on the “8-Slot” Basic Cabinet P31003-H3560-S403-54-7620, 09/05 4-114 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 593: Figure 4-65 Hipath 3750 - Backplane On The "8-Slot" Expansion Cabinets

    Cable connector to EC2: X14 Cable connector to BC: X12 Cable connector to BC: X14 X28 - X88 1 SU connector each (16 TW) to MDFU or MDFU-E P31003-H3560-S403-54-7620, 09/05 4-115 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 594 Connect BC to EC1 = 2 cables (S30267-Z178-A13) System (see Figure 4-66) Three-cabinet Connect BC to EC1 = 2 cables (S30267-Z178-A13) ● System Connect BC to EC2 = 2 cables (S30267-Z178-A13) ● (see Figure 4-67) P31003-H3560-S403-54-7620, 09/05 4-116 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 595: Figure 4-66 Two-Cabinet "8-Slot" System - Connection Cables Between

    EC1 = S30777-Q708-X100 ● Connection cable part num- bers For connecting BC to EC1 = ● S30267-Z178-A13 Figure 4-66 Two-Cabinet “8-Slot” System - Connection Cables between BC and EC1 P31003-H3560-S403-54-7620, 09/05 4-117 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 596: Figure 4-67 Three-Cabinet "8-Slot" System - Connection Cables Between Bc

    EC1: Between slots 11 + 12 and 13 + 14 and 15 + 16 and 17 + UPSM ● EC2: Between slots 20 + 21 and 22 + 23 and 24 + 25 and 26 + UPSM ● P31003-H3560-S403-54-7620, 09/05 4-118 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 597: Connection Between The Mdfu Or Mdfu-E And Backplane

    A direct connection is set up to the NT or networked system via the back- TMS2 plane connector SU Xx9 and a special cable (see Section 3.3.42, “TMS2 (Not for U.S.)”). P31003-H3560-S403-54-7620, 09/05 4-119 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 598 An adapter (1 SU connector - 8-pin MW8 (RJ48C) jack, Figure 4-68) is con- nected directly to the SU Xx9 backplane connector. You can use a special cable to create a direct connection to the CSU or networked system. P31003-H3560-S403-54-7620, 09/05 4-120 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 599: Figure 4-68 S 2M Adapter (Sipac 1 Su - Mw8 (Rj48C)) C39228-A7195-A12

    (SIPAC 1 SU - MW8 (RJ48C) MW8 (RJ48C jack SIPAC 1 SU (to the NT, CSU jack (Xx9 or networked backplane) system) Figure 4-68 Adapter (SIPAC 1 SU - MW8 (RJ48C)) C39228-A7195-A12 P31003-H3560-S403-54-7620, 09/05 4-121 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 600 Stripped length = 910 ± 5 mm for MDFU-E slots 1 to 10 Velcro tape (19 mm wide) Bundle fastener Figure 4-69 Stripping an Open-End Cable (not for the U.S.) P31003-H3560-S403-54-7620, 09/05 4-122 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 601 P31003-H3560-S403-54-7620, 09/05 4-123 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 602: Laying The Line Network And Setting Jumpers On The Mdfu Or

    (outside stations) ● lines > 500 m long. ● Connect the polarized surge protectors to the plugging locations on the splitting strip described above (see Figure 4-69). P31003-H3560-S403-54-7620, 09/05 4-124 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 603 Cable 2 (SU Xx9) No. 25 not used Jumper strip for 25 TW (C39334-A166-A3) Figure 4-70 Assignment (Numbering) of the Splitting/Jumper Strips, (view from above) (not for U.S.) P31003-H3560-S403-54-7620, 09/05 4-125 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 604 Special built-in comps. 2 x PFT1 1 x PFT4 System side Line network Figure 4-71 MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.) P31003-H3560-S403-54-7620, 09/05 4-126 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 605: Mdfu-E

    2 x PFT1 System side Line network The MDFU-E is delivered with most systems. Figure 4-72 MDFU-E - Layout and Dimensions (669.0 x 328.8 x 125.4 mm) (not for U.S.) P31003-H3560-S403-54-7620, 09/05 4-127 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 606: For U.s. Only: Connecting Network Facilities

    ● * If not connected to facility provider terminal equipment. ** When this module is connected to the public network, secondary protection must be provided by the CSU. P31003-H3560-S403-54-7620, 09/05 4-128 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 607: Installing Hipath 3700 (19-Inch Cabinet)

    ● board configuration ● final visual inspection ● applies to both HiPath 3700 and HiPath 3750 and is described starting in Section 4.3.5. P31003-H3560-S403-54-7620, 09/05 4-129 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 608: Selecting The Installation Site

    Determine whether any damage has occurred during transport and report it to the proper departments. Dispose of the packing materials properly. Caution Only use tools and equipment that are in perfect condition. Do not use equipment with visible damage. P31003-H3560-S403-54-7620, 09/05 4-130 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 609: Mounting The System Cabinet In The 19-Inch Cabinet

    To replace a cover, position the snap fasteners in the two guides and press down on the cover until it snaps into place. P31003-H3560-S403-54-7620, 09/05 4-131 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 610 19-inch cabinet. To replace a cover, position the snap fasteners in the two guides and press down on the cover until it snaps into place. P31003-H3560-S403-54-7620, 09/05 4-132 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 611: Mounting The System Cabinet With Angle Brackets

    19-inch frame. Attach the system cabinet to the angle bracket (B) in the 19-inch cabinet frame using two screws per bracket. P31003-H3560-S403-54-7620, 09/05 4-133 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 612: Figure 4-74 Hipath 3700 - Installation In The 19-Inch Cabinet

    Caution Be careful when breaking out the recesses. Remove any sharp edges and corners. P31003-H3560-S403-54-7620, 09/05 4-134 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 613: Mounting The Patch Panel In The 19-Inch Cabinet

    19-inch frame using two screws (B) on each side. Mounting the patch panel Figure 4-75 HiPath 3700 - Mounting the Patch Panel P31003-H3560-S403-54-7620, 09/05 4-135 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 614: Grounding The System

    The 19-inch cabinet’s potential equalization bus may only be used if it is grounded by a separate ground conductor. Failure to follow these instructions can result in electrical shock. P31003-H3560-S403-54-7620, 09/05 4-136 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 615 Min. cross-section = 2.5 mm Min. cross-section = 2.5 mm Potential equalization bus, in 19" cabinet for example Figure 4-76 HiPath 3700- Grounding the Systems and Patch Panels in a 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-137 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 616: Checking The Grounding

    < 1 ohm tem parts (basic cabinet, expansion cabinets, patch pan- els). Prerequisite: HiPath 3700 is not yet connected to the low-voltage net- work via the power cable. P31003-H3560-S403-54-7620, 09/05 4-138 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 617: Connecting The Cable To The Backplane

    The “8-slot” basic cabinet has seven slots, while the expansion cabinets each have > eight slots for peripheral boards. Backplane on the “8-slot” basic cabinet CBCPR UPSM REAL only) Figure 4-77 HiPath 3700 - Backplane on the “8-Slot” Basic Cabinet P31003-H3560-S403-54-7620, 09/05 4-139 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 618: Cabinet

    Cable connector to EC2: X14 Cable connector to BC: X12 Cable connector to BC: X14 X28 - X88 1 SU connector each (16 TW) to the patch panel P31003-H3560-S403-54-7620, 09/05 4-140 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 619 Connect BC to EC1 = 2 cables (S30267-Z178-A13) System (see Figure 4-79) Three-cabi- Connect BC to EC1 = 2 cables (S30267-Z178-A13) ● Connect BC to EC2 = 2 cables (S30267-Z178-A13) ● System (see Figure 4-80) P31003-H3560-S403-54-7620, 09/05 4-141 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 620 EC1 = S30777-Q708-X100 ● Connection cable part num- bers For connecting BC to EC1 = ● S30267-Z178-A13 Figure 4-79 Two-Cabinet “8-Slot” System - Connection Cables between BC and EC1 P31003-H3560-S403-54-7620, 09/05 4-142 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 621: Figure 4-80 Three-Cabinet "8-Slot" System - Connection Cables Between

    EC1: Between slots 11 + 12 and 13 + 14 and 15 + 16 and 17 + UPSM ● EC2: Between slots 20 + 21 and 22 + 23 and 24 + 25 and 26 + UPSM ● P31003-H3560-S403-54-7620, 09/05 4-143 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 622 SU Xx9 backplane connector. You can use a special ca- ble (see Section 3.3.42, “TMS2 (Not for U.S.)”) to create a direct connection to the NT or networked system. P31003-H3560-S403-54-7620, 09/05 4-144 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 623 An adapter (1 SU connector - 8-pin MW8 (RJ48C) jack, Figure 4-86) is con- nected directly to the SU Xx9 backplane connector. You can use a special cable to create a direct connection to the CSU or networked system. P31003-H3560-S403-54-7620, 09/05 4-145 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 624: Figure 4-81 Patch Panel S30807-K6143-X

    (outside stations) ● lines > 500 m long. ● Connect the polarized surge protectors to slots F1 – F8 provided on the patch panel (seeFigure 4-82). P31003-H3560-S403-54-7620, 09/05 4-146 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 625 Direct connector jumpering on the X12/X13 connector. Bridges are not necessary in ● this case. X12, X14 X13, X15 Figure 4-82 Structure of the Patch Panel S30807-K6143-X P31003-H3560-S403-54-7620, 09/05 4-147 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 626: Figure 4-83 S

    Refer to the following tables for information on the assignment of the MW8 jacks: Table 3-107 for STMD8 board ● Table 3-173 for REAL board ● P31003-H3560-S403-54-7620, 09/05 4-148 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 627: Figure 4-84 Laying Wire Pairs At The S Patch Panel

    8 7 6 3 2 1 4 5 Pin assignment of MW8 jacks Twist the wire pairs before laying them. Figure 4-84 Laying Wire Pairs at the S Patch Panel P31003-H3560-S403-54-7620, 09/05 4-149 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 628: Figure 4-85 Stripping The Open-End Cable For The S Patch Panel

    Figure 4-85 Stripping the Open-End Cable for the S Patch Panel P31003-H3560-S403-54-7620, 09/05 4-150 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 629: Figure 4-86 S 2M Adapter (Sipac 1 Su - Mw8 (Rj48C)) C39228-A7195-A12

    (SIPAC 1 SU - MW8 (RJ48C) MW8 (RJ48C jack SIPAC 1 SU (to the NT, CSU jack (Xx9 or networked backplane) system) Figure 4-86 Adapter (SIPAC 1 SU - MW8 (RJ48C)) C39228-A7195-A12 P31003-H3560-S403-54-7620, 09/05 4-151 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 630: Connecting The Line Network To The Patch Panel

    Front panel with 3 x 16 MW8 jacks each SLA16N, SLC16N SLA16N, SLC16N SLA16N, SLC16N SLA24N SLA16N, SLC16N SLA24N Figure 4-87 Layout of the Patch Panel S30807-K6143-X for Different Peripheral Boards P31003-H3560-S403-54-7620, 09/05 4-152 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 631: Loading The System Software And Installing Subboards On The Cbcpr

    Place the central control board on a flat surface before installing subboards. The spacing bolts supplied guarantee the correct insertion of the subboard, so you should always mount them (see Figure 3-6). Otherwise you may damage the board. P31003-H3560-S403-54-7620, 09/05 4-153 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 632: Configuration Notes

    Depending on their width, peripheral boards can be inserted in slots 02 to 08 in the BC, 10 to 17 in EC1 and 19 to 26 in EC2 (the adhesive label beneath each slot identifies the slot) (see Figure 4-88). P31003-H3560-S403-54-7620, 09/05 4-154 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 633: Figure 4-88 Slot Numbers And Widths In "8-Slot" Bc, Ec1, And Ec2

    Slot width (mm): Expansion cabinets EC1 and EC2 Slot no., EC1: UPSM EC2: UPSM Slot width (mm): Figure 4-88 Slot Numbers and Widths in “8-Slot” BC, EC1, and EC2 P31003-H3560-S403-54-7620, 09/05 4-155 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 634 If it has, the board is not activated. The board LED shows the board’s status. At least one B channel on line trunk modules is available for the slot (only the available ● number of B channels is activated). P31003-H3560-S403-54-7620, 09/05 4-156 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 635 To avoid B-channel blocking, install the TMST1 board only in the BC or in the first two slots of the ECs. HiPath 3000 Manager E observes this rule when performing off-line configuration. P31003-H3560-S403-54-7620, 09/05 4-157 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 636 Depends on the number of mobile telephones logged on SLMO8, SLMO24 Depends on the number of stations (hosts (master) and clients (slave)) STMD8 TIEL TMDID8 TML8W TMS2 TMST1 P31003-H3560-S403-54-7620, 09/05 4-158 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 637 The figures below show the PCM segments (64 time-division multiplex channels each) for the different HiPath 3750 and HiPath 3700 system configurations. Single-cabinet system: PCM segments “8-slot” cabinets Figure 4-90 PCM Segments for a One-Cabinet System P31003-H3560-S403-54-7620, 09/05 4-159 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 638: Figure 4-91 Pcm Segments For A Two-Cabinet System

    Two-cabinet system: PCM segments “8-slot” cabinets Figure 4-91 PCM Segments for a Two-Cabinet System Three-cabinet system: PCM segments “8-slot” cabinets Figure 4-92 PCM Segments for a Three-Cabinet System P31003-H3560-S403-54-7620, 09/05 4-160 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 639: Table 4-17 Hipath 3750 And Hipath 3700 - Static Traffic Capacity

    (see Figure 4-92) 12 + 13 + 21 + 22 64 erlangs 14 + 15 + 23 + 24 64 erlangs 16 + 17 + 25 + 26 64 erlangs P31003-H3560-S403-54-7620, 09/05 4-161 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 640: Inserting Or Removing Boards

    Locking and Unlocking Boards Figure 4-93 Locking and unlocking boards Special board attachments The power supply is screwed onto the grill of each cabinet. P31003-H3560-S403-54-7620, 09/05 4-162 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 641: Connecting Workpoint Clients

    TMAMF (for selected countries only) ● TML8W (Not for U.S.) (MSI) ● TIEL ● TMDID8 (for U.S. only) ● TMGL8 (for U.S. only) ● TMST1 (for U.S. only) ● P31003-H3560-S403-54-7620, 09/05 4-163 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 642: Performing A Visual Inspection

    Check the local line voltage. Digital multimeter After finishing the visual inspection, you can begin starting up the HiPath 3750 or Hi- > Path 3700 system as described in Chapter 5. P31003-H3560-S403-54-7620, 09/05 4-164 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 643: Installing Hipath 3550, Hipath 3350, Hipath 3500, And Hipath 3300

    Telephone test set for analog interfaces – Not for U.S.: ISDN tester (such as K3000 or Aurora) Duet Expert, Remote – For U.S. only: Aurora , Aurora Aurora or similar, ISDN protocol analyzer P31003-H3560-S403-54-7620, 09/05 4-165 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 644: Installation Procedure

    Configuration notes, page 4-183 Making trunk connections, page 4-200 Connecting Workpoint Clients, page 4- Performing a Visual Inspection, page 4- Making trunk connections, page 4-187 Performing a Visual Inspection, page 4- P31003-H3560-S403-54-7620, 09/05 4-166 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 645: Installing Hipath 3550 And Hipath 3350

    Avoid standard carpeting, as it tends to produce electrostatic charges. ● Ensure that Siemens equipment is 40 in. (101.6 cm) from other electrical equipment. The ● National Electrical Code (NEC) requires 36 in. (91.44 cm) of clearance in front of electrical equipment and 40 in.
  • Page 646 Allow 20 in. (50.8 cm) of clearance on the bottom (for cables). Figure 4-94 HiPath 3550 and HiPath 3350 - Space Requirements (for U.S. only) P31003-H3560-S403-54-7620, 09/05 4-168 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 647: For U.s. Only: Ac Outlet

    A warning should be attached to the circuit breaker to prevent accidental removal of power. ● An independent electric circuit with an isolated ground conductor should be used. ● Recommendation: Add a power surge protector between the outlet and the system. ● P31003-H3560-S403-54-7620, 09/05 4-169 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 648: Unpacking The Components

    MDF to the wall. The MDFU must be grounded. Refer to Section 4.4.3.6 for an explanation of the procedure. P31003-H3560-S403-54-7620, 09/05 4-170 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 649 Special built-in comps. 2 x PFT1 1 x PFT4 System side Line network Figure 4-95 MDFU - Layout and Dimensions (367.0 x 328.8 x 125.4 mm) (not for U.S.) P31003-H3560-S403-54-7620, 09/05 4-171 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 650: Removing The System Housing Cover

    HiPath 3550 and HiPath 3350 housing cover. Procedure Step Activity Loosen the two screwed plugs on the housing cover with a slotted screw driver. Hold the housing cover so that it does not fall. P31003-H3560-S403-54-7620, 09/05 4-172 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 651 To close the system housing again, put the cover on and fasten it with the two screwed plugs. To avoid injuries, grasp the housing cover by its outside walls only when mounting it. P31003-H3560-S403-54-7620, 09/05 4-173 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 652: Attaching The System To The Wall

    Oblong holes for 30 cm Minum clearance for replacing boards Figure 4-96 HiPath 3550 and HiPath 3350 - Wall Attachment Figure 4-97 HiPath 3550 and HiPath 3350 - Wall Attachment P31003-H3560-S403-54-7620, 09/05 4-174 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 653: Grounding The System And The Main Distribution Frame

    For U.S. only: ● The customer supplies a main distribution frame to complete the communications system. Mount and ground the MDF in accordance with the manufacturer’s instructions. P31003-H3560-S403-54-7620, 09/05 4-175 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 654 - central heating system - drain channels - ground conductor for antenna system Figure 4-98 HiPath 3550, HiPath 3350 - Grounding an External Main Distribution Frame P31003-H3560-S403-54-7620, 09/05 4-176 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 655: Installing The Boards

    Connecting to T1, PRI, or CorNet (for U.S. only) Caution The TST1 Module (HiPath 3550) can be installed only in conjunction with a listed channel service unit (CSU). P31003-H3560-S403-54-7620, 09/05 4-177 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 656: Laying The Line Network And Connection Cables

    6 slip-on connectors (4 TW each) for connection to the HiPath 3550 and HiPath 3350 boards Figure 4-99 Layout of CABLU S30269-Z41-A30 (Length = 3 m) P31003-H3560-S403-54-7620, 09/05 4-178 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 657 As shown in Figure 4-101, you can connect the eight-pin slip-on connectors to the boards directly. The line network connects directly to the jumper strip. P31003-H3560-S403-54-7620, 09/05 4-179 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 658 (Octopus cable with Amphenol terminators). You select the output pat- tern on the Amphenol connector by which slip-on connector you use on each board edge connector. P31003-H3560-S403-54-7620, 09/05 4-180 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 659: Attaching Ferrite

    5 mm min. 15 mm – Ferrite sleeve C39022-Z7000-C7 Power cable Figure 4-102 HiPath 3550 and HiPath 3350 - Power Cable with Ferrite Sleeve P31003-H3560-S403-54-7620, 09/05 4-181 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 660 If the number of lines makes this impossible, the ferrite “small” format can be attached directly at the output of the cable duct. P31003-H3560-S403-54-7620, 09/05 4-182 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 661: Configuration Notes

    TST1 boards must be ob- > served. HiPath 3550: system overview and slots Cable duct Optional boards Slot levels Figure 4-103 HiPath 3550 - Wall Housing System Overview P31003-H3560-S403-54-7620, 09/05 4-183 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 662 HiPath 3550 - Slots in the Wall Housing The CBCC board is connected to the optional board via a ribbon ca- ble (OPAL) (see adjacent figure). Figure 4-105 HiPath 3550 - Option Adapter Long (OPAL) P31003-H3560-S403-54-7620, 09/05 4-184 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 663 Slot levels Figure 4-106 HiPath 3350 - Wall Housing System Overview CUP: Connection Unit Point OPAL Slot levels Figure 4-107 HiPath 3350 - Slots in the Wall Housing P31003-H3560-S403-54-7620, 09/05 4-185 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 664: Table 4-21 Hipath 3550 And Hipath 3350 - Static Traffic Capacity

    Use of a TS2 board results in a capacity of 30 erlangs. A maximum of one TS2 per HiPath 3550 is possible, and the board may only be installed in slot 7 or 9, thus resulting in 30 Erlangs for slot 7 or 9. P31003-H3560-S403-54-7620, 09/05 4-186 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 665: Connecting Workpoint Clients

    Check the local line voltage. Digital multimeter After finishing the visual inspection, you can begin starting up the system as de- > scribed in Chapter 5. P31003-H3560-S403-54-7620, 09/05 4-187 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 666: Installing Hipath 3500 And Hipath 3300 (19-Inch Housing)

    You can also install an ECR expansion cabinet rack in which you can install a battery pack (for uninterruptible power supply) and/or an additional external power supply EPSU2-R (if the sys- tem’s internal power supply is not sufficient) (see Section 9.2.4). P31003-H3560-S403-54-7620, 09/05 4-188 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 667: Selecting The Installation Site

    Wall Outlet Configura- voltage Range tions from from 120 V AC/ 110 V AC 130 V AC 47 Hz 63 Hz NEMA 5-15, 2-pin, 3- 60 Hz wire, earth P31003-H3560-S403-54-7620, 09/05 4-189 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 668: Unpacking The Components

    Determine whether any damage has occurred during transport and report it to the proper departments. Dispose of the packing materials properly. Caution Only use tools and equipment that are in perfect condition. Do not use equipment with visible damage. P31003-H3560-S403-54-7620, 09/05 4-190 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 669: Not For U.s.: Attaching A Hipath 3500 And Hipath 3300 To The Wall

    Drill a second hole in the wall for the lower angle bracket (B), insert a wall anchor and attach the angle bracket with a screw. Wall mounting HiPath 3500 / HiPath 3300 Figure 4-108 HiPath 3500 and HiPath 3300 - Wall Installation (for U.S.) P31003-H3560-S403-54-7620, 09/05 4-191 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 670: Installing A Hipath 3500 Or Hipath 3300 In A Cabinet

    3300 using two screws per bracket. Slide the HiPath 3500 or HiPath 3300 system into the 19-inch cabinet and attach it to the left and right of the 19-inch frame with screws. P31003-H3560-S403-54-7620, 09/05 4-192 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 671: Figure 4-109 Hipath 3500 And Hipath 3300 - Mounting The 19-Inch Cabinet

    Installing HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300 Mounting the 19-inch cabinet HiPath 3500 HiPath 3300 HiPath 3500 Figure 4-109 HiPath 3500 and HiPath 3300 - Mounting the 19-Inch Cabinet P31003-H3560-S403-54-7620, 09/05 4-193 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 672: Grounding The System

    (230 Vac), you must hire a li- censed electrician to install the ground. If you answer “Yes” to both questions, the HiPath 3500 or HiPath 3300 systems may be grounded as described below. P31003-H3560-S403-54-7620, 09/05 4-194 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 673: Installing The Boards

    Failure to follow these instructions can result in electrical shock. 4.4.4.7 Installing the Boards The systems are already equipped with the boards needed for the customer’s specific require- ments. P31003-H3560-S403-54-7620, 09/05 4-195 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 674: Connecting Cables And The Line Network

    Attaching to the ECR side (see Page 9-9) ● Line network The connecting cords to the peripherals can be connected directly to the relevant MW8 jacks on the front panel of the 19-inch housing. P31003-H3560-S403-54-7620, 09/05 4-196 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 675: Figure 4-112 Hipath 3500 - Slot Levels In The 19-Inch Housing

    Slot 4 Slot 5 1 (Peripheralboards) Figure 4-112 HiPath 3500 - Slot Levels in the 19-Inch Housing It is imperative that you observe the restrictions regarding TS2R installation. > P31003-H3560-S403-54-7620, 09/05 4-197 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 676: Figure 4-113 Hipath 3300 - Slot Levels In The 19-Inch Housing

    (C39165-A7027-B115) to close slots that are not equipped with boards. Slot levels: 3 (options) Slots 1-3 2 (CBRC) 1 (Peripheralboards) Slot 4 Slot 5 Figure 4-113 HiPath 3300 - Slot Levels in the 19-Inch Housing P31003-H3560-S403-54-7620, 09/05 4-198 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 677 Use of a TS2R board results in a capacity of 30 erlangs. A maximum of one TS2R per HiPath 3500 is possible, and the board may only be installed in slot 7 or 9, thus resulting in 30 Erlangs for slot 7 or 9. P31003-H3560-S403-54-7620, 09/05 4-199 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 678: Connecting Workpoint Clients

    Check the local line voltage. Digital multimeter After finishing the visual inspection, you can begin starting up the system as de- > scribed in Chapter 5. P31003-H3560-S403-54-7620, 09/05 4-200 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 679: Starting Up Hipath 3000

    This chapter discusses the topics listed in the following table. Topic Starting Up HiPath 3800, page 5-2 Starting Up HiPath 3750 and HiPath 3700, page 5-11 Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300, page 5-19 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 680: Startup Procedure

    Carrying Out the Country Initialization and Selecting the Password Type, page 5-7 Not for U.S.: Entering the System Number, page 5-9 Customer-Specific Programming, page 5-10 Performing a System Check, page 5-10 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 681: Supplying The System With Power

    = 0.75 s on/0.25 s off ● The HiPath 3800 is ready when the date “1. JAN 00” and the time “00:00” appear in > the display on the system telephone. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 682: Assigning Station Numbers

    Board was inserted ahead of another board in the place- ● ment sequence: Board is activated and appended to the last board in the numbering plan. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 683 S board can result in gaps in line numbering. This is because all S ports are ini- tially activated as trunks and are only subse- quently reconfigured. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 684: Carrying Out A System Reload

    Press and hold down the reset switch for at least 5 seconds (FAIL LED (red) goes out). If you do not hold down the reset switch for a full 5 seconds, the system may perform a reset rather than a reload or may not reload properly. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 685 1 = Variable password 2 = Fixed password You are prompted to enter the country code (see Page A- 26). The system then boots up with the country-specific de- fault information. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 686: Table 5-3 Entering The Country Code And Selecting The Password Type

    Brazil and with connection to analog trunks with DTMF signaling. After you enter a country code, the default data is only guaranteed to load correctly > if the system software has been officially released for that country. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 687: Not For U.s.: Entering The System Number

    Watch the display. Scroll until “ISDN parameters” and “PABX number” appear. Confirm your selection. Expert mode: Enter the code 20 2 1 to 4. Follow the user prompting on the display. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 688: Customer-Specific Programming

    Perform random terminal tests as described in Section 12.3.1.8 on all telephones. ● Checking for proper system booting Set up internal and external calls at random to check if the system is functioning properly. ● P31003-H3560-S403-54-7620, 09/05 5-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 689: Table 5-5 Hipath 3750 And Hipath 3700 - Startup Procedure

    Carrying Out the Country Initialization and Selecting the Password Type, page 5- Not for U.S.: Entering the System Number, page 5-17 Customer-Specific Programming, page 5-18 Performing a System Check, page 5-18 P31003-H3560-S403-54-7620, 09/05 5-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 690: Table 5-6 Run Led - Led Status Meaning

    The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm. The HiPath 3750 or HiPath 3700 is ready when the date “1. JAN 00” and the time > “00:00” appear in the display on the system telephone. P31003-H3560-S403-54-7620, 09/05 5-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 691: Assigning Station Numbers

    Board was inserted ahead of another board in the place- ● ment sequence: Board is activated and appended to the last board in the numbering plan. P31003-H3560-S403-54-7620, 09/05 5-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 692 ● lines on one STMD8 can result in gaps in line numbering. This is because all STMD8 ports are initially activated as trunks and are only subsequently reconfigured. P31003-H3560-S403-54-7620, 09/05 5-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 693: Carrying Out A System Reload

    XXXXX You are prompted to enter a new password (max. 15 digits) XXXXX You are prompted to confirm the password entered in step 29 - 5 Country initialization P31003-H3560-S403-54-7620, 09/05 5-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 694 Brazil and with connection to analog trunks with DTMF signaling. After you enter a country code, the default data is only guaranteed to load correctly > if the system software has been officially released for that country. P31003-H3560-S403-54-7620, 09/05 5-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 695: Not For U.s.: Entering The System Number

    Scroll until “ISDN parameters” and “PABX number” appear. Confirm your selection. Expert mode: Enter the code 20 2 1 to 4. Follow the user prompting on the display. P31003-H3560-S403-54-7620, 09/05 5-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 696: Customer-Specific Programming

    Perform random terminal tests as described in Section 12.3.1.8 on all telephones. ● Checking for proper system booting Set up internal and external calls at random to check if the system is functioning properly. ● P31003-H3560-S403-54-7620, 09/05 5-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 697: Startup Procedure

    Carrying Out the Country Initialization and Selecting the Password Type, page 5- Not for U.S.: Entering the System Number, page 5-25 Customer-Specific Programming, page 5-26 Performing a System Check, page 5-26 P31003-H3560-S403-54-7620, 09/05 5-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 698: Supplying The System With Power

    The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm. The system is ready when the date “1. JAN 00” and the time “00:00” appear in the > display on the system telephone. P31003-H3560-S403-54-7620, 09/05 5-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 699: Assigning Station Numbers

    Board was inserted ahead of another board in the place- ● ment sequence: Board is activated and appended to the last board in the numbering plan. P31003-H3560-S403-54-7620, 09/05 5-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 700 (HiPath 3000 Manager E). The system does not assign the MSN until the S ● port is configured on the “Euro bus”; the MSN can be read out via administration. P31003-H3560-S403-54-7620, 09/05 5-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 701: Carrying Out A System Reload

    You are prompted to enter a new password (max. 15 digits) XXXXX You are prompted to confirm the password entered in step 4. 29 - 5 Country initialization P31003-H3560-S403-54-7620, 09/05 5-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 702 Table A-3, HiPath 3550, HiPath 3350 and HiPath 3500 have not been introduced in some of the countries listed in HiPath 3300. The correct loading of the default data is not guaranteed for those countries. P31003-H3560-S403-54-7620, 09/05 5-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 703: Not For U.s.: Entering The System Number

    Scroll until “ISDN parameters” and “PABX number” appear. Confirm your selection. Expert mode: Enter the code 20 2 1 to 4. Follow the user prompting on the display. P31003-H3560-S403-54-7620, 09/05 5-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 704: Customer-Specific Programming

    Perform random terminal tests as described in Section 12.3.1.8 on all telephones. ● Checking for proper system booting Set up internal and external calls at random to check if the system is functioning properly. ● P31003-H3560-S403-54-7620, 09/05 5-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 705: Overview

    Configuring HiPath 5000 with HiPath ComScendo Service, page 6-50 ● Reloading the HiPath ComScendo Service (if required), page 6-51 ● Configuring HiPath 5000 RSM as a Central Administration Unit in an IP Network, page 6- ● HiPath Manager PCM, page 6-56 GetAccount, page 6-57 Parameters for Call Data Export, page 6-57 ●...
  • Page 706 HiPath 5000 Startup and Administration Overview Topic Connecting an Uninterruptible Power Supply to HiPath 5000, page 6-62 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 707: Introduction

    M1). HG 1500 in HiPath 3000 and HG3550 V2.0 in HiPath 4000 are prerequisites for IP networking over CorNet IP. Parts of the following setup for HiPath 5000 are optional and can be installed both on the HiPath 5000 Real-Time Services Manager RSM and on a separate PC.
  • Page 708 ● tion of personal call forwarding operations) HiPath FM Desktop V3.0 (Java-based application for error signaling) ● GetAccount (application that prepares generated call data records for further processing.) ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 709 HiPath Cordless Office IP Network optiClient 130 optiClient Attendant V5.0 optiPoint 500 ... optiset E ... PSTN HiPath 3500 HiPath 3750 Figure 6-1 HiPath 5000 RSM Multi-Node IP System P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 710: Software Structure

    Software Structure Feature Server The Feature Server is an essential component in the HiPath 5000 software architecture and serves as a central point for administration and as a data interface for applications and middle- ware. In addition, the Feature Server synchronizes the HG 1500 boards with all necessary data for digit analysis in a HiPath 3000/5000 network.
  • Page 711 VEvtLogMsg.dll AssCkds.dll vsrv.exe Accs520x.dll Accs520x.dll Accs520x.dll Accs520x.dll Server Database vdbaccess.dll Socket Interface Data Transfer Interface Remote Procedure Call Interface vsock.dll vadmtftp.dll FCT.dll Figure 6-3 Feature Server Services and Routines P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 712: Table 6-1 Feature Server Components

    CSTA monitor point cannot be set on a call number of this type. The dssserver.exe service for the Presence Manager is installed with the HiPath 5000 software. This is a user-configured service that receives its information from vaplx.dll. The TAPI Ser- vice Provider is required for the Presence Manager to work.
  • Page 713: Notes On Open Numbering In A Hipath 3000/5000 Network

    The node number (Settings/System parameters.../Flags: Node number) and the in- > coming PABX number for route 16 (HG 1500 route) (Settings/Lines / networking.../ Routes: PABX number - incoming) should be identical for every HiPath 3000 system. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 714: Installation Requirements

    HiPath 5000 Startup and Administration Installation Requirements Installation Requirements To use HiPath 5000, the following minimum requirements must be met: Hardware and software ● Table 6-2 HW and SW Minimum Requirements for HiPath 5000 Component New system Upgrade an existing system to V6.0...
  • Page 715: Prerequisites For A Single-Pc Solution

    Prerequisites for a Single-PC Solution Table 6-4 shows the maximum expansion level permitted for the HiPath ComScendo Service together with HiPath 5000 RSM (central administration unit in an IP network) and other appli- cations on a single PC. Table 6-4 Prerequisites for a Single-PC Solution Upgrade V4.0 to...
  • Page 716 If the customer is unwilling to accept restrictions, HiPath ComScendo Service must be installed on a separate PC. P31003-H3560-S403-54-7620, 09/05 6-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 717: Preparing For Installation

    Make sure that no unnecessary hardware is connected to the server PC; any sound cards should be removed. Access privileg- To install HiPath 5000, you must log on to the operating system with admin- istrator rights or, if necessary, log on as the server domain administrator. LAN integration Check to ensure that the server PC has been correctly integrated in the cus- tomer LAN (see Section 6.6.2).
  • Page 718: Integrating The Hipath 5000 Server In The Customer Lan

    Once the data has been customized, a reboot is required. ● Test the LAN connection with a “ping” to another computer ● Integrate the HiPath 5000 in the Windows domain under Control Panel - Network - Identi- ● fication (a domain administrator account is required here!) P31003-H3560-S403-54-7620, 09/05 6-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 719: Hipath 5000 Installing Standard Components

    HiPath 5000 Installing Standard Components 6.6.3.1 Overview The installation program (Master Setup) enables both the basic installation of a HiPath 5000 system including middleware and components for system administration/analysis and the post- installation of individual software components and tools (update, see Section 6.7).
  • Page 720: Licensing

    The system falls into licensing default if licensing is not performed within the 30-day grace pe- riod. This means that features which subject to mandatory licensing will suffer from reduced functionality. P31003-H3560-S403-54-7620, 09/05 6-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 721: Starting The Installation

    Click Next to proceed with the installation routine. Select destination path. Select the folder where you want to install the program. Confirm the default folder c:\program files\siemens\hipath\ with Next or click Browse and select a different folder. Select program folder.
  • Page 722 The subsequent description of the installation procedure relates to the default setup. Information on installing the HiPath ComScendo Service can be found in Section 6.6.4. P31003-H3560-S403-54-7620, 09/05 6-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 723 Click Next to start the copy operation. The PC reboots after installing the MSDE 2000 SQL database. > The installation procedure is automatically continued after rebooting. P31003-H3560-S403-54-7620, 09/05 6-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 724 10. The File Transfer Folder appears. Select the folder where you want to install the files. Confirm the default folder c:\program files\siemens\hipath\tftp\files\ with Next or click Change to select a different folder. P31003-H3560-S403-54-7620, 09/05 6-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 725 12. Click Next to proceed with the setup routine. 13. When all selected components are installed, a dialog appears in which you can terminate the setup with Finish. P31003-H3560-S403-54-7620, 09/05 6-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 726: Installing Hipath Comscendo Service

    Click Next to proceed with the installation routine. Select destination path. Select the folder where you want to install the program. Confirm the default folder c:\program files\siemens\hipath\ with Next or click Browse and select a different folder. Select program folder.
  • Page 727 HiPath 5000 Startup and Administration HiPath 5000 The Select Features dialog appears. Select the HiPath ComScendo Service components you want to install and deselect the ones you do not want to install. P31003-H3560-S403-54-7620, 09/05 6-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 728 To implement the setup for the HiPath ComScendo service, both a TFTP server and an FM Reporting client must be installed on the relevant PC. Both components are automatically selected and installed by the Master Setup. P31003-H3560-S403-54-7620, 09/05 6-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 729 PC. Select the folder where you want to install the program. Confirm the default folder c:\program files\siemens\hipath\tftp\files\ with Next or click Change to select a different folder. P31003-H3560-S403-54-7620, 09/05 6-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 730 Note: This dialog only appears if none of the Master Setup components has been installed on the PC. Enter the trap destinations (if necessary) and the HiPath Fault Management desktop com- munity names. P31003-H3560-S403-54-7620, 09/05 6-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 731 The Select Network Card dialog appears. Note: This dialog only appears if the relevant PC has more than one network card. Select the network card for HiPath 5000. P31003-H3560-S403-54-7620, 09/05 6-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 732 12. Continue setup with Next. The Country selection dialog appears. Confirm the default or select a different country to define the international standard settings for language, currency and date format. P31003-H3560-S403-54-7620, 09/05 6-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 733 5000\pcsdata\ with Next or click Change to select a different folder. 14. When all selected components are installed, a dialog appears in which you can terminate the installation with Finish. P31003-H3560-S403-54-7620, 09/05 6-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 734: Checking The Installation Of The Hipath Comscendo Service

    HiPath 5000 6.6.4.1 Checking the Installation of the HiPath ComScendo Service Procedure Open the status display with Start/Program Files/HiPath/HiPath 5000 State Viewer. The following appears: Make sure that the server status is "Running" and that all service status indicators are green.
  • Page 735: Installing Hipath Fault Management

    6.6.5 Installing HiPath Fault Management HiPath Fault Management can read information from the HiPath 3000 and HiPath 5000 system MIB via SNMP requests. This allows the system to permanently monitor the status of the net- work components and to include changes of status in the network administrator information.
  • Page 736 HiPath 5000 Startup and Administration HiPath 5000 The Select Features dialog appears. Select the HiPath Fault Management components you want to install and deselect the ones you do not want to install. P31003-H3560-S403-54-7620, 09/05 6-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 737 Select the folder where you want to install the Java Runtime Environment. Confirm the default folder c:\program files\javasoft\jre\<version>\ with Next or click Browse and select a different folder. P31003-H3560-S403-54-7620, 09/05 6-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 738 17. Once installation is complete, a final dialog appears. Close the InstallShield Wizard for Hi- Path Fault Management with Finish. 18. A message appears indicating that the master setup has been successful. Close the setup with Finish. P31003-H3560-S403-54-7620, 09/05 6-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 739: Installing The Tapi Service Provider

    Confirm the subsequent system message to enable the ACD service if the Call Center ap- plication HPCO is connected. The TAPI service provider is now installed. For further information, please refer to the online help for the TAPI Service Provider. P31003-H3560-S403-54-7620, 09/05 6-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 740: Installing The Hipath Inventory Server Separately

    Click Next to proceed with the installation routine. Select destination path. Select the folder where you want to install the program. Confirm the default folder c:\program files\siemens\hipath\ with Next or click Browse and select a different folder. Select program folder.
  • Page 741 HiPath 5000 Startup and Administration HiPath 5000 The Select Features dialog appears. Select the HiPath Inventory components you want to install and deselect the ones you do not want to install. P31003-H3560-S403-54-7620, 09/05 6-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 742 To be able to implement the setup for HiPath Inventory, both an FM Reporting client and a Common Web Service must be installed on the relevant PC. Both components are auto- matically selected and installed by the Master Setup. P31003-H3560-S403-54-7620, 09/05 6-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 743 Click Next to start the copy operation. The Trap Destinations and Communities dialog appears. Enter the trap destinations (if necessary) and the HiPath Fault Management desktop com- munity names. P31003-H3560-S403-54-7620, 09/05 6-39 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 744 Enter the IP address and the port number of the PC where the database is installed (MSDE SQL database server). 11. Confirm your entries with Next. 12. When installation is complete, a dialog appears in which you can terminate the setup with Finish. P31003-H3560-S403-54-7620, 09/05 6-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 745: Verifying Installation

    Working with Computer Management requires an appropriate level of familiarity with the operating system. 6.6.8.1 Verifying the Start and Function of HiPath 5000 Services Select Computer Management - Services and Applications - Services to check if all necessary services were started.
  • Page 746: Checking Entries In The Event Viewer

    6.6.8.2 Checking Entries in the Event Viewer The Event Viewer (event log) provides status information on the HiPath 5000 server and any application servers available. All events associated with the server(s) and its (their) applications are saved. The events pro- vide a quick and, above all, time-specific overview of all relevant actions (status, information, warning, error, etc.).
  • Page 747: Modifying Hipath 5000 Components (Retro-Fitting, Updating, Deleting)

    (features) of the current HiPath 5000 installation. ● When activated, the Setup creates the relevant selection lists based on the current HiPath 5000 installation. The WinAccount software for evaluating call data records is no longer used in HiPath >...
  • Page 748: Version-Wide Upgrading Of A Hipath 5000 Installation

    170 Service Provider Help). Save the current CDB files of all connected systems (see HiPath 3000 Manager E Help). Call up the HiPath 5000 State Viewer with Start/Programs/HiPath/HiPath 5000 State Viewer. Exit the HiPath 5000 server by clicking Stop Server.
  • Page 749 Note: As these directories are not installed via Master Setup, it is not possible to delete them via the setup maintenance program. Install the components (features) for the new version (refer to the instructions in Section 6.6.3). P31003-H3560-S403-54-7620, 09/05 6-45 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 750: Performing Licensing

    Management. The procedure is used in all HiPath products, for example communication sys- tems, workpoint clients, and applications. A grace period of 30 days begins when HiPath 5000 is started up. Licensing must be performed for all features, interfaces, and products subject to mandatory licensing within this grace period.
  • Page 751: Optimizing Operating System Settings

    Optimizing the physical Windows 2000 Server is normally optimized for maximum throughput memory as a file server. For a HiPath 5000 server, however, significantly less memory is needed for the system-wide disk cache. For this select the Balance Load option under Start/Settings/ Network and DC Connections/LAN Connection: Proper- ties –...
  • Page 752 Configure the following by right-clicking Properties under System Log and Application Log in the operating system’s Event Viewer: 'Overwrite events as needed' and set 'Maximum log size' to approxi- mately 2 MB. P31003-H3560-S403-54-7620, 09/05 6-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 753: Perform Hipath 5000 Basic Configuration

    HG 1500 resources (see Page 10-38) are administered over Web-based Management (WBM). HiPath 5000 RSM as central administration unit in an IP network, with or without HiPath ● ComScendo Service .The formation of a “single system image” allows the central admin- istration of all associated nodes (HiPath 3000 and HiPath 5000 with HiPath ComScendo Service).
  • Page 754: Configuring Hipath 5000 With Hipath Comscendo Service

    Select Read/Write Database. Set the Overwrite and Hardware flags and transfer the cus- tomer database by clicking the PC –> System button. Once transfer is complete, HiPath 5000 automatically performs a reset and then returns to operation. The HG 1500 resources (see Page 10-38) are to be administered with Web-based >...
  • Page 755: Reloading The Hipath Comscendo Service (If Required)

    ● The directory in which the two PDS files are to be stored is defined when the HiPath 5000 soft- ware is installed (setup). The two PDS files are created when the HiPath 5000 is started for the first time.
  • Page 756: Configuring Hipath 5000 Rsm As A Central Administration Unit In An

    Activate the HiPath 5000 RSM/AllServe server by selecting File - HiPath 5000 RSM/ AllServe - Transfer or via the appropriate button in the toolbar. The menu item File - HiPath 5000 RSM/AllServe - New - HiPath 5000 RSM/ > AllServe Server is only used to create a CDB memory generated offline.
  • Page 757 The Transfer (HiPath 5000 RSM/AllServe Server) dialog appears. The PC to be used as the HiPath 5000 server should be entered in the Server field. Note: If the required software is not installed on the specified PC, the error message "Hi- Path 5000 RSM/AllServe Server not Installed on this PC"...
  • Page 758: Adding Individual Nodes For Ip Networking

    (see Chapter 4, “Installing HiPath 3000”) and startup (see Chapter 5, “Start- ing Up HiPath 3000”) of these systems. Procedure To select the node to be added to the CDB, call File - HiPath 5000 RSM/AllServe - New - HiPath 3000. The Enter Source dialog appears.
  • Page 759 CDB firstly created to all other CDB files of the node belonging to IP networking. Confirm the selection of the source with the Finish button. To add the node, invoke File - HiPath 5000 RSM/AllServe - Transfer - HiPath 5000 RSM/ AllServe Server. The Transfer (HiPath 5000 RSM/AllServe Server) dialog appears.
  • Page 760: Hipath Manager Pcm

    HiPath 5000 Startup and Administration HiPath Manager PCM 6.11 HiPath Manager PCM For information, see the HiPath Manager PCM Installation and Administration Manual. P31003-H3560-S403-54-7620, 09/05 6-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 761: Getaccount

    6.12.1 Parameters for Call Data Export For HiPath 5000, you can forward the existing call data, for example, for external call charge calculation. The call data is forwarding in an ASCII file. Proceed as follows to set the parameters for call data export: Start the GetAccount Administration program.
  • Page 762 The ASCII transfer file is automatically saved in the specified folder and extended to in- clude the new call data. The file is extended by one line for each call data record. Each call data record (line) is ended with CR+LF. P31003-H3560-S403-54-7620, 09/05 6-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 763: Table 6-8 Getaccount - Data Record Structure

    101 - 5 Trunk right-aligned with leading blanks 106 - 4 LCR Selected Route (corresponds to configuration in HiPath 3000 Manager E) right-aligned with leading blanks 1 CR P31003-H3560-S403-54-7620, 09/05 6-59 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 764 HiPath 5000 Startup and Administration GetAccount Table 6-8 GetAccount - Data Record Structure Pos. Lengt Description 1 LF P31003-H3560-S403-54-7620, 09/05 6-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 765 To avoid uncontrolled folder growth with the transfer file, an option is available for de- > leting the renamed transfer file after forwarding it for external use in this folder. P31003-H3560-S403-54-7620, 09/05 6-61 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 766: Connecting An Uninterruptible Power Supply To Hipath 5000

    Online’s P 500 uninterruptible power supply (UPS) was certified for use with HiPath 5000. The P 500 UPS is fed through the AC power cord to the HiPath 5000 server. The device bridges power failures lasting 5 - 10 minutes by means of an integrated battery.
  • Page 767: Table 6-9 P 500 Ups - Meaning Of Displays, Switches And Jacks

    Special monitoring software can shut down the specified server via this jack, for exam- ple, in the case of extended power failures. Jacks for power supply to the communication server to be monitored. P31003-H3560-S403-54-7620, 09/05 6-63 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 768 HiPath 5000 Startup and Administration Connecting an Uninterruptible Power Supply to HiPath 5000 P31003-H3560-S403-54-7620, 09/05 6-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 769: Starting Hipath 3000 As A Gateway

    Starting HiPath 3300 as a Gateway, page 7-8 Introduction So-called gateways provide the HiPath 5000 with interfaces for trunk and tie trunk connections to the telecommunications network. In V6.0, the HiPath 3800, HiPath 3700, HiPath 3500, and HiPath 3300 systems can be used as gateways.
  • Page 770: Starting Hipath 3800 As A Gateway

    Refer to the following board descriptions for information: STMD3 - for S trunk connection ● DIUN2 - for S trunk connection ● DIU2U (For U.S. Only) - for T1 PRI trunk ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 771 Set up internal and external calls at random to check if the system is func- tioning properly. Test IP configuration ● Ping the HG 1500 IP address in the gateway. Set up external calls at random (from optiPoints or optiClients on HiPath 5000). P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 772: Starting Hipath 3700 As A Gateway

    Refer to the following board descriptions for information: STMD8 - for S trunk connection ● TMS2 (Not for U.S.) - for S trunk connection ● TMST1 (for U.S. only) - for T1 PRI trunk ● P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 773 Set up internal and external calls at random to check if the system is func- tioning properly. Test IP configuration ● Ping the HG 1500 IP address in the gateway. Set up external calls at random (from optiPoints or optiClients on HiPath 5000). P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 774: Starting Hipath 3500 As A Gateway

    Note: Analog workpoint clients can be connected to the CBRC’s T/R ports in emer- gencies. This ensures telephone operation via the telecommunications network in the event of IP network failure. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 775 Set up internal and external calls at random to check if the system is func- tioning properly. Test IP configuration ● Ping the HG 1500 IP address in the gateway. Set up external calls at random (from optiPoints or optiClients on HiPath 5000). P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 776: Starting Hipath 3300 As A Gateway

    IP network failure. Making IP connections Perform the IP connection over the HG 1500 board HXGR3. For information on startup and configuration, refer to the HG 1500 Administration Manual. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 777 Set up internal and external calls at random to check if the system is func- tioning properly. Test IP configuration ● Ping the HG 1500 IP address in the gateway. Set up external calls at random (from optiPoints or optiClients on HiPath 5000). P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 778 Starting HiPath 3000 as a Gateway Starting HiPath 3300 as a Gateway P31003-H3560-S403-54-7620, 09/05 7-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 779: Introduction

    Combining Standalone Systems (HiPath 3000) to Form a Network with HiPath 5000 ● RSM, page 8-20 Removing a Standalone System from a Network with HiPath 5000 RSM, page 8-22 ● Replacing License-sensitive Hardware (Changing the MAC Address), page 8-23 ●...
  • Page 780 Introduction Introduction Versions 5.0 and later of HiPath 3000 and HiPath 5000 use a new, centralized licensing proce- dure known as HiPath License Management. The procedure is used in all HiPath products, for example communication systems, workpoint clients, and applications.
  • Page 781 Manager E 4. License file is validated which are subject to man- datory licensing 5. License file is analyzed Figure 8-1 Licensing Process with Central License Server (CLS) P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 782: Licensing For Hipath 3000 V6.0, Hipath 5000 V6.0

    8.3.1 Products and Components subject to Mandatory Licensing The following products used with HiPath 3000 and HiPath 5000 V6.0 must be licensed (i.e. are subject to mandatory licensing). The required licenses are combined in a license file and must be distributed to the relevant products using HiPath 3000 Manager E.
  • Page 783 VPN Workpoint Clients ● CSTA Service Provider (CSP) ● TAPI Service Provider (TSP) ● HiPath Fault Management ● Information on the licensing procedure can be found in the appropriate product documentation. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 784: Grace Period

    If the error has not been rectified by the time the 30-day license failure period has expired, the systems enter system default mode. This means that features which subject to mandatory li- censing will suffer from reduced functionality. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 785: Performing Licensing

    > available to the user. During installation of the Customer License Agent CLA on the service PC or on the HiPath 5000 server (see Figure 8-2), an import subdirectory is created in the installation directory. If the user has received a valid license file (<license>.xml), there are two options: The license file can be stored manually in the specified subdirectory import.
  • Page 786 HiPath 5000 RSM, a separate license file must be requested for each sys- tem. Networked HiPath 3000 systems Figure 8-2 Distribution of Licenses with HiPath 3000 Manager E P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 787 The license distribution procedure described below requires successful installation (see Chapter 4, “Installing HiPath 3000”) and startup (see Chapter 5, “Starting Up HiPath 3000”) of the HiPath 3000 systems (nodes) and, if available, of the HiPath 5000 RSM (see Chapter 6, “HiPath 5000 Startup and Administration”).
  • Page 788 “HXG”, “S2M”, “IVM” and “Base station” tabs. Distribute the licenses defined in the license file to the individual features. Note that in a network with HiPath 5000 RSM, these are the licenses for all of the nodes (HiPath 3000) belonging to the network.
  • Page 789 5000 network for a customer. Licensing is required for the network at the preconfig- uration stage. If there is no valid license file available, licensing can also be per- formed using a GPCF file. P31003-H3560-S403-54-7620, 09/05 8-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 790: Licensing Scenarios

    Activate the Generate Key button. In the subsequent dialog, define the number of licenses to be generated and specify the MAC address to which the license should be linked. P31003-H3560-S403-54-7620, 09/05 8-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 791: Networked Hipath 3000 Systems Without Hipath 5000 Rsm

    This file is linked with the MAC address of the control board belonging to the relevant system. The procedure for generating the various license keys is the same as that in Section 8.4.1. P31003-H3560-S403-54-7620, 09/05 8-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 792: Networked Hipath 3000 Systems With Hipath 5000 Rsm

    HiPath 3000 Manager E (In cases where the MAC address is not already avail- able): The MAC address of the HiPath 3000 system control board with the lowest node num- ber (node ID) should be determined. P31003-H3560-S403-54-7620, 09/05 8-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 793 Click the Execute button. A new license key is generated. After successful execution, the message "License Key Generation Complete" ap- pears The generation information and license key data is displayed. Click License Key. P31003-H3560-S403-54-7620, 09/05 8-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 794 In the subsequent dialog, specify the storage location for the license key you want to download. Section 8.3.4 describes the procedure for distributing licenses with HiPath 3000 Man- ager E. P31003-H3560-S403-54-7620, 09/05 8-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 795: Upgrading To Hipath 3000 V6.0, Hipath 5000 V6.0

    8.4.4 Upgrading to HiPath 3000 V6.0, HiPath 5000 V6.0 To upgrade from a version earlier than 5.0 to HiPath 3000 V6.0 or HiPath 5000 V6.0, you must request a new license file and repeat the licensing procedure. The Central License Server (CLS) enables the old licenses (< V5.0) to be converted into new licenses that are valid for version 6.0.
  • Page 796 The MAC address of the HiPath 3000 control board to which the HG 1500 board specified under step 5 belongs should be entered in the MAC Address input field. Click Next. P31003-H3560-S403-54-7620, 09/05 8-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 797 Invoke the License Management Center homepage. Activate the "View Used Licenses and Certificates" function under "Management of Used Licenses". Various search criteria are displayed for calling the recently upgraded license key. P31003-H3560-S403-54-7620, 09/05 8-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 798: Hipath 5000 Rsm

    HiPath License Management: Invoke the Central License Server (CLS) via https://www.central-license- server.com/ Select the language version for the License Management Center. Log on by entering the user name and password. P31003-H3560-S403-54-7620, 09/05 8-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 799 Invoke the License Management Center homepage. Activate the "View Used Licenses and Certificates" function under "Management of Used Licenses". Various search criteria are displayed for invoking the generated license key. P31003-H3560-S403-54-7620, 09/05 8-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 800: Removing A Standalone System From A Network With Hipath 5000 Rsm

    Removing a Standalone System from a Network with HiPath 5000 If a standalone node (HiPath 3000) is to be removed from a network with HiPath 5000 RSM, a new license file is required for the standalone system. A new, network-wide general license file must also be requested for the rest of the network.
  • Page 801: Replacing License-Sensitive Hardware (Changing The Mac Address)

    In the subsequent dialog, define the MAC address to which the new license should be linked. In the "MAC Address" input field, enter the MAC address for the new control board. Click Next. P31003-H3560-S403-54-7620, 09/05 8-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 802 In the subsequent dialog, specify the storage location for the license key you want to download. Section 8.3.4 describes the procedure for distributing licenses with HiPath 3000 Man- ager E. P31003-H3560-S403-54-7620, 09/05 8-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 803 The new license key (see step 12) must be used to achieve valid licensing. Section 8.3.4 describes the procedure for distributing licenses with HiPath 3000 Manager E. P31003-H3560-S403-54-7620, 09/05 8-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 804: Licensing Opticlient Attendant

    Procedure for Licensing optiClient Attendant V7.0 on HiPath 3000 V6.0 Step Activity (Remarks) Read the customer data record of the HiPath 3000 V6.0. Read out the MAC address of the HiPath 3000 control board. P31003-H3560-S403-54-7620, 09/05 8-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 805 HiPath 3000 expires. The 30-day limit cannot be ex- tended and a second grace period will not be granted. In this case, the CLS generates a license key for HiPath 3000 V6.0. P31003-H3560-S403-54-7620, 09/05 8-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 806: Opticlient Attendant V7.0 Connected To Hipath 3000 < V5.0

    Transfer the license key from the CLS via the CLM to the CLA either a) via CLM/CLS communication, ● b) manually on the CLM (license key is already available, offline activation). ● P31003-H3560-S403-54-7620, 09/05 8-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 807 The 30-day limit cannot be extended and a second grace period will not be granted. In this case, the CLS generates a license key for the CLA PC, and not for HiPath 3000. P31003-H3560-S403-54-7620, 09/05 8-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 808: Upgrading Opticlient Attendant V6.0 -> V7.0 As Part Of An Upgrade To Hipath

    Licensing procedure when upgrading optiClient Attendant V6.0 –> V7.0 on Hi- Path 3000 V5.0 Step Activity (Remarks) Read the customer data record of the HiPath 3000 V5.0. Read out the MAC address of the HiPath 3000 control board. P31003-H3560-S403-54-7620, 09/05 8-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 809 Attendant expires. The 30-day limit cannot be extended and a second grace period will not be granted. In this case, the CLS generates a license key for HiPath 3000 V5.0. P31003-H3560-S403-54-7620, 09/05 8-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 810: Upgrade Opticlient Attendant V6.0 -> V7.0 On Hipath 3000 < V5.0

    Enter the LAC and MAC address and the CD key of the optiClient Attendant V6.0 at the CLS in order to generate the license key. Input is only possible directly via the CLS (direct communication with the CLS via web browser). P31003-H3560-S403-54-7620, 09/05 8-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 811 In this case, the CLS generates a license key for the CLA PC, and not for HiPath 3000. Note: For CLS, an optiClient Attendant V7.0 is generally specified as a “HiPath 3000/ 5000 V5.0 product” and “HiPath 3000 optiClient Attendant V7.0 feature”. P31003-H3560-S403-54-7620, 09/05 8-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 812: Changing Licenses On An Opticlient Attendant V7.0 As Part Of An Upgrade To Hipath 3000 V5.0

    At- tendant (CLS) HiPath 3000 V5.0 HiPath 3000 Manager E Figure 8-7 Changing Licenses on an optiClient Attendant V7.0 As Part of an Upgrade to HiPath 3000 V5.0 P31003-H3560-S403-54-7620, 09/05 8-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 813 Attendant expires. The 30-day limit cannot be extended and a second grace period will not be granted. In this case, the CLS generates a license key for HiPath 3000 V5.0. P31003-H3560-S403-54-7620, 09/05 8-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 814: Protection Against License Manipulation

    The full functionality of the CLA on this PC can only be restored by means of a repair or a reinstallation (see the License Agent Installation Manual). P31003-H3560-S403-54-7620, 09/05 8-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 815: Expanding And Upgrading Hipath 3000

    Software Upgrade, page 9-31 ● Converting the customer database when changing a system, page 9-36 Converting the customer database from HiPath 3750/HiPath 3700 to HiPath 3800, page ● 9-36 P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 816: Replacing Peripheral Boards For Hipath 3800

    If the number is already assigned to a different object, you can switch both numbers. Replacing board with Board is activated. The same station range is used. same or under equipped board type P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 817 E to retain the old station data by copying it to the new board, or you can delete it and reset the default state. Copying is not possible for trunk boards. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 818: Replacing Peripheral Boards For Hipath 3750 And Hipath 3700

    E to retain the old station data by copying it to the new board, or you can delete it and reset the default state. Copying is not possible for trunk boards. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 819: P31003-H3560-S403-54-7620,

    E to retain the old station data by copying it to the new board, or you can delete it and reset the default state. Copying is not possible for trunk boards. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 820: Connecting A Printer

    Figure 9-1 Sample Connection of a CDR Printer to HiPath 3000 Information on assigning V.24 interfaces from other systems is provided in the board descrip- tions in Chapter 3. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 821 Expanding and Upgrading HiPath 3000 Expanding HiPath 3000 Output formats For information about the output formats (compressed or uncompressed) for call detail record- ing central, see HiPath 3000/5000 Feature Description. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 822: Ecr With Hipath 3700, Hipath 3500, Hipath 3300 (Not For U.s. And Canada)

    (corded or cordless tele- phones). In this case, the EPSU2-R external power supply unit should be installed in the ECR. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 823: Ecr Control, Display, And Connecting Elements

    Batteries/EPSU2-R [2] output voltage to UPSC-DR for HiPath 3500 and HiPath 3300 ● Batteries output voltage [2] to UPSM for HiPath 3700 Clip [3] ● Attach the braided screen of the connection cable (to the jack [2]) here. P31003-H3560-S403-54-7620, 09/05 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 824: Figure 9-3 Ecr Rear Panel With Connecting Elements

    LED [5] for the -48-V output voltage (DC output) in the EPSU2-R (see Table 9-3) ● LED [6] for the line input voltage (AC input) in the EPSU2-R (see Table 9-3) ● Figure 9-3 ECR Rear Panel With Connecting Elements P31003-H3560-S403-54-7620, 09/05 9-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 825 (power failure or system powered by batteries, including addition- al power). No AC input voltage (power outage) and batteries are empty, or the EPSU2-R fuse is defective or was removed (by turning to the left). P31003-H3560-S403-54-7620, 09/05 9-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 826: Components

    19-inch cabinet (see Section 4.4.4.5). ● mounted on a wall (see Section 4.4.4.4). ● set up on a table using four adhesive mounting feet. ● P31003-H3560-S403-54-7620, 09/05 9-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 827: Expansion Cabinet Rack Ecr With Batteries

    4 batteries –48 V UP2 12 V/7 Ah F1 T6.3 A –48 V BatB +48 V Figure 9-4 HiPath 3700, HiPath 3500, HiPath 3300 - ECR With Batteries P31003-H3560-S403-54-7620, 09/05 9-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 828: Figure 9-5 Ecr With Built-In Batteries

    (6.3 A/T) in the front panel of the ECR. When shipping an ECR with built-in batteries, the batteries must be removed before- hand. Figure 9-5 ECR With Built-In Batteries P31003-H3560-S403-54-7620, 09/05 9-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 829: Installing Batteries

    Remove the ECR housing cover: To do this, remove the three screws at the rear and slide the housing cover back. Remove the mounting screw [A] on the battery retainer [B]. Remove the battery retainer and set aside. P31003-H3560-S403-54-7620, 09/05 9-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 830 Expanding and Upgrading HiPath 3000 Expanding HiPath 3000 Step Activity Insert the batteries carefully in the recesses provided [C]. Replace the battery retainer and secure the mounting screw. P31003-H3560-S403-54-7620, 09/05 9-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 831 Insert the battery fuse (ECR front panel) (see Section 9.2.4.1). Set the switches for battery voltage and line voltage on the ECR’s front panel to "On" (see Section 9.2.4.1). P31003-H3560-S403-54-7620, 09/05 9-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 832: Expansion Cabinet Rack Ecr With Batteries And Epsu2-R

    ECR and the power supply unit of the system (UPSC-DR). The connection cable be- tween the expansion cabinet rack ECR and the system cabinet is also provided. P31003-H3560-S403-54-7620, 09/05 9-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 833 (6.3 A/T) in the front panel of the ECR. When shipping an ECR with built-in batteries, the batteries must be removed before- hand. P31003-H3560-S403-54-7620, 09/05 9-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 834: Figure 9-7 Ecr With Built-In Epsu2-R

    Expanding and Upgrading HiPath 3000 Expanding HiPath 3000 EPSU2-R Figure 9-7 ECR with Built-In EPSU2-R P31003-H3560-S403-54-7620, 09/05 9-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 835: Connecting A Fan (If Needed)

    Insert the battery fuse (ECR front panel) (see Section 9.2.4.1). Set the switches for battery voltage and line voltage on the ECR’s front panel to "On" (see Section 9.2.4.1). P31003-H3560-S403-54-7620, 09/05 9-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 836: Figure 9-8 Connecting The Fan To The Epsu2-R

    Expanding and Upgrading HiPath 3000 Expanding HiPath 3000 Figure 9-8 Connecting the Fan to the EPSU2-R P31003-H3560-S403-54-7620, 09/05 9-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 837: Figure 9-9 Placement Of The Fan In The Ecr

    If you install the fan at a later time, you must make sure that the identification ([B] in Figure 9- 9) is in the upper right corner when viewed from outside. Figure 9-9 Placement of the Fan in the ECR P31003-H3560-S403-54-7620, 09/05 9-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 838: Connecting Special Equipment

    1 µF/250 V for each to the T/R analog port Amplifier Figure 9-11 Direct Connection of Entrance Telephones P31003-H3560-S403-54-7620, 09/05 9-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 839: Information On Third-Party Entrance Telephones

    Power supply NG 602-0 ● Connection Power supply NG 602-0 HiPath 3000 Siedle-Vario TLM 612 DoorCom Analog DCA 612-0 Figure 9-12 Connecting DoorCom Analog to HiPath 3000 P31003-H3560-S403-54-7620, 09/05 9-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 840 Flags = Missed Calls List Device control features (open doors, select entrance telephone, etc.) can be programmed on procedure keys. The stored DTMF signal sequence is sent to the application. P31003-H3560-S403-54-7620, 09/05 9-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 841: Connecting Speakers

    Amplifier SLA/SLAS Starting contact REAL/STRBR/ STRBR HiPath 3000 Active speak- ers only SLA/SLAS HiPath 3000 Amplifier SLA/SLAS Starting contact Figure 9-13 Connecting Speakers to an Analog Station Port P31003-H3560-S403-54-7620, 09/05 9-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 842: Figure 9-14 Connecting Speakers To An Analog Trunk Port

    Connecting speakers to an analog trunk port Active speakers HiPath 3000 only TML/TLA HiPath 3000 Amplifier TML/TLA Starting contact REAL/STRB Figure 9-14 Connecting Speakers to an Analog Trunk Port P31003-H3560-S403-54-7620, 09/05 9-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 843: Upgrading Hipath 3000 To V6.0

    For Deutsche Telekom AG only: The CBCP board S30810-Q2935-B201 must be replaced by a CBCC board S30810-Q2935-A301. Multimedia card MMC with 64 MB is required to run HiPath 3000/5000 V5.0 and higher. P31003-H3560-S403-54-7620, 09/05 9-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 844 STMI2, S30810-Q2316-X100 and higher HiPath 3750 HXGM3, S30810-Q2942-X and higher HiPath 3700 HiPath 3550 HXGS3, S30810-Q2943-X and higher HiPath 3350 HiPath 3500 HXGR3, S30810-K2943-Z and higher HiPath 3300 P31003-H3560-S403-54-7620, 09/05 9-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 845: Software Upgrade

    HG 1500 board System clients station HG 1500 board slot 6 slot 6 station: HG 1500 gateway HFA clients Lines Figure 9-15 Differences Between V4.0 and V5.0 Configurations P31003-H3560-S403-54-7620, 09/05 9-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 846 Open V4.0 CDB using HiPath Open V4.0 CDB using HiPath 3000 Manager E. 3000 Manager E. Figure 9-16 Flowchart for CDB Conversion from V4.0 –> V5.0 (Part 1 of 4) P31003-H3560-S403-54-7620, 09/05 9-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 847: Figure 9-17 Flowchart For Cdb Conversion From V4.0 -> V5.0 (Part 2 Of 4)

    Check whether the number of all Save CDB. configured stations and lines is 0. Figure 9-17 Flowchart for CDB Conversion from V4.0 –> V5.0 (Part 2 of 4) P31003-H3560-S403-54-7620, 09/05 9-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 848: Figure 9-18 Flowchart For Cdb Conversion From V4.0 -> V5.0 (Part 3 Of 4)

    Enter the number of lines re- quired. Configure all V4.0 HFA clients as H.323 clients. Figure 9-18 Flowchart for CDB Conversion from V4.0 –> V5.0 (Part 3 of 4) P31003-H3560-S403-54-7620, 09/05 9-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 849 Define the slot(s) for the HG 1500 gateway. Configure S stations. V5.0 conversion complete. Save CDB. Figure 9-19 Flowchart for CDB Conversion from V4.0 –> V5.0 (Part 4 of 4) P31003-H3560-S403-54-7620, 09/05 9-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 850: Converting The Customer Database When Changing A System

    In systems with more than one TMS2 card (HiPath 3750/HiPath 3700) these are replaced ● by the same number of DIUN2 cards (HiPath 3800). If not, manual corrections are neces- sary. TMOM (HiPath 3750/HiPath 3700) is not incorporated. ● P31003-H3560-S403-54-7620, 09/05 9-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 851 In HiPath 3750/HiPath 3700 systems, 23 slots are available for peripheral cards. The card ● in slot 26 is not incorporated because HiPath 3800 only has 22 slots. P31003-H3560-S403-54-7620, 09/05 9-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 852 Expanding and Upgrading HiPath 3000 Converting the customer database when changing a system P31003-H3560-S403-54-7620, 09/05 9-38 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 853: Workpoint Clients

    Maximum Configuration for UP0/E Workpoint Clients, Add-On Devices and Adapters, ● page 10-33 optiPoint 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S, page 10-36 IP Telephony (Voice over IP), page 10-38 ● P31003-H3560-S403-54-7620, 09/05 10-1 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 854 Attendant, page 10-80 ● Mobile Telephones for HiPath Cordless Office, page 10-85 Gigaset S1 professional, page 10-85 ● Gigaset SL1 professional, page 10-86 ● Gigaset M1 professional, page 10-87 ● P31003-H3560-S403-54-7620, 09/05 10-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 855 Gigaset active EX, page 10-89 ● Logging Mobile Telephones On To the System, page 10-91 ● Analog Telephones for HiPath 3000, page 10-94 ISDN Terminals for HiPath 3000, page 10-95 P31003-H3560-S403-54-7620, 09/05 10-3 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 856 500 entry and optiPoint 500 economy) and because the adapters are plug "n" play". You can find information not contained in this chapter in the optiPoint 500 Service Manual. P31003-H3560-S403-54-7620, 09/05 10-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 857 Instructions" (refer to Section 1.6, “Information on the Intranet”: Electronic Docu- mentation on Com ESY Products). – with the “Online Key Labeling Tool” that can be downloaded from http://www.sie- mens.com/hipath (–> Downloads). P31003-H3560-S403-54-7620, 09/05 10-5 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 858: Optipoint 500

    Consultation hold Number redial Message Callback Speed dialing Microphone on/off Loudspeaker Disconnect Figure 10-1 optiPoint 500 entry - Standard Key Assignment (Default) Refer to Section 10.2.1.6 for connection requirements. P31003-H3560-S403-54-7620, 09/05 10-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 859: Optipoint 500 Economy (Not For U.s.)

    Microphone on/off Programmable Loudspeaker Programmable Programmable Programmable Programmable Disconnect Figure 10-2 optiPoint 500 economy (not for U.S.) - Standard Key Assignment (Default) Refer to Section 10.2.1.6 for connection requirements. P31003-H3560-S403-54-7620, 09/05 10-7 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 860: Optipoint 500 Basic

    Number redial Programmable Microphone on/off Programmable Loudspeaker Programmable Programmable Programmable Programmable Disconnect Figure 10-3 optiPoint 500 basic - Standard Key Assignment (Default) Refer to Section 10.2.1.6 for connection requirements. P31003-H3560-S403-54-7620, 09/05 10-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 861: Optipoint 500 Standard, Optipoint 500 Standard Sl (For U.s. Only)

    Interfaces and slots: ● – 1 integrated USB 1.1 interface – 1 option bay – 1 interface for up to 2 add-on devices Suitable for wall mounting ● P31003-H3560-S403-54-7620, 09/05 10-9 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 862: Figure 10-4 Optipoint 500 Standard - Standard Key Assignment (Default)

    Number redial Programmable Microphone on/off Programmable Loudspeaker Programmable Programmable Programmable Programmable Disconnect Figure 10-4 optiPoint 500 standard - Standard Key Assignment (Default) Refer to Section 10.2.1.6 for connection requirements. P31003-H3560-S403-54-7620, 09/05 10-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 863: Optipoint 500 Advance

    1 integrated USB 1.1 interface – 2 option bays – 1 interface for up to 2 add-on devices – 1 headset port (121 TR9-5) Suitable for wall mounting ● P31003-H3560-S403-54-7620, 09/05 10-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 864: Figure 10-5 Optipoint 500 Advance - Standard Key Assignment (Default)

    Programmable Programmable Programmable Programmable Programmable Programmable Programmable Programmable Programmable Programmable Disconnect Figure 10-5 optiPoint 500 advance - Standard Key Assignment (Default) Refer to Section 10.2.1.6 for connection requirements. P31003-H3560-S403-54-7620, 09/05 10-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 865: Connection Requirements For Hipath 3000

    The device can also be connected to an existing optiPoint 500 telephone (except for > optiPoint 500 entry and optiPoint 500 economy) as a client telephone (using an op- tiPoint Phone Adapter). P31003-H3560-S403-54-7620, 09/05 10-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 866: Connection

    LEDs on the add-on devices (AODs), if connected, light up briefly (AOD LEDs do not ● necessarily flash at the same time as the LEDs on the telephone) all pixels on the display activate briefly. ● P31003-H3560-S403-54-7620, 09/05 10-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 867: Connections On The Bottom Of The Telephone

    MW8 (RJ45) connection jack for HiPath 3000 MW4 (RJ8) connection jacks: Upper = headset equip- ment Lower = handset Option bays (see Figure 10-10) Figure 10-6 optiPoint 500 Connection Options P31003-H3560-S403-54-7620, 09/05 10-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 868: Usb 1.1 Interface

    Attendant - the professional PC attendant console is connected over the > USB 1.1 interface of the optiPoint 500 basic, optiPoint 500 standard or optiPoint 500 advance. P31003-H3560-S403-54-7620, 09/05 10-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 869: Optipoint 500 Add-On Devices

    The optiPoint key module is an add-on device that should be mounted on the side of the tele- phone; it provides an additional 16 keys, LEDs and labelling areas for all purposes. Figure 10-7 optiPoint Key Module P31003-H3560-S403-54-7620, 09/05 10-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 870: Optipoint Blf

    Power is supplied using a power supply unit (see Section 10.7.1.1) that can supply power to up to two optiPoint BLFs. The power supply unit must be plugged directly into the designated op- tiPoint BLF port. Figure 10-8 optiPoint BLF P31003-H3560-S403-54-7620, 09/05 10-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 871: Optipoint Application Module (V5.0 Smr-06 And Later)

    The following sections contain information on the possible add-on device configurations: Section 10.2.2.4 for terminals in the optiPoint 500 family ● Section 10.3.5.3 for terminals in the optiPoint 410 and optiPoint 420 family ● P31003-H3560-S403-54-7620, 09/05 10-19 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 872: Possible Add-On Device Configurations

    BLF optiPoint 500 advance optiPoint BLF – optiPoint BLF optiPoint BLF Configuration with two optiPoint BLFs only with HiPath 3800, HiPath 3750, and HiPath 3700 P31003-H3560-S403-54-7620, 09/05 10-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 873: Optipoint 500 Adapters

    Option bays: 2 x for optiPoint 500 ● advance (shown here) 1 x for optiPoint 500 ● basic and optiPoint 500 standard Figure 10-10 optiPoint 500 Option Bays P31003-H3560-S403-54-7620, 09/05 10-21 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 874: Optipoint Analog Adapter

    Supports only DTMF with Flash ● No ground signaling allowed ● Does not support: VoiceMail server with T/R interface, message waiting lamp, dictating ● equipment, speaker, announcement device (such as start/stop). P31003-H3560-S403-54-7620, 09/05 10-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 875: Optipoint Isdn Adapter

    Maximum 200 m (656 feet) with a cable impedance of 150 ohms (complies with CCITT recommendation I.430) The NT terminating resistors are integrated into the ISDN adapter. ● P31003-H3560-S403-54-7620, 09/05 10-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 876: Optipoint Phone Adapter

    (for J-Y (ST) 2x2x0.6, ∅ 0.6 mm). MW6 (RJ11) socket assignments: Signal Free AUX – (a) – P0/E P0/E AUX + (b) Free Figure 10-13 optiPoint Phone Adapter P31003-H3560-S403-54-7620, 09/05 10-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 877: Figure 10-14 Example Of A Host-Client Configuration

    Local power sup- Local power supply ply (optional) (optional) Client Host optiPoint 500 telephone with optiPoint optiPoint 500 telephone phone adapter Figure 10-14 Example of a Host-Client Configuration P31003-H3560-S403-54-7620, 09/05 10-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 878: Optipoint Acoustic Adapter

    The internal microphone, the transmitter inset and any microphone connected to the opti- ● Point acoustic adapter are muted in the “Mute” audio state. P31003-H3560-S403-54-7620, 09/05 10-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 879 Input resistance: 150 kΩ parallel to 220 nF in series with 36 kΩ Sense lead to GND: internal microphone deactivated. Figure 10-16 Y Cable for optiPoint acoustic adapter P31003-H3560-S403-54-7620, 09/05 10-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 880: Table 10-2 Floating Contacts On The Optipoint Acoustic Adapter

    This can be used, for example, to control a secondary bell. The contact can be loaded with up to 5 W at 24 Vac or 60 Vdc. Free – P31003-H3560-S403-54-7620, 09/05 10-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 881: Optipoint Recorder Adapter

    Beep tone level: -26 dBm to -18 dBm at a 600 Ω load Max. input level: 650 mVeff from a 600 Ω source Figure 10-17 optiPoint Recorder Adapter P31003-H3560-S403-54-7620, 09/05 10-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 882: Possible Optipoint Adapter Configurations

    Section 10.2.5 shows the maximum number of adapters and add-on devices that can be con- nected to HiPath 3000/5000. The limits also include the client telephones connected over opti- Point phone adapters and the analog telephones connected over optiPoint analog adapters. P31003-H3560-S403-54-7620, 09/05 10-30 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 883: Comparison Of Optiset E Adapters And Optipoint 500 Adapters

    USB interface control adapter ISDN adapter ISDN adapter acoustic adapter acoustic adapter contact adapter headset adapter headset plus adapter recorder adapter P31003-H3560-S403-54-7620, 09/05 10-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 884: Information On Supplying Power To Optipoint 500 Add-On Devices And Optipoint 500 Adapters

    BLFs. An additional external power supply is required if the floating contacts on the optiPoint acoustic adapters are being used. P31003-H3560-S403-54-7620, 09/05 10-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 885: Maximum Configuration For U P0/E Workpoint Clients, Add-On Devices

    E telephones Number per system 250/384 ● Number per box (the value in – – – – ● brackets applies to operation us- (120) ing a PSUI) P31003-H3560-S403-54-7620, 09/05 10-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 886 If the total number of U stations, analog stations and additional stations connected using an adapter is greater than P0/E 72, an external EPSU2 power supply unit must be used. P31003-H3560-S403-54-7620, 09/05 10-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 887 Workpoint Clients optiPoint 500 If the total number of U stations and additional stations connected using an adapter is greater than 24, a UPSC-D/ P0/E UPSC-DR must be used. P31003-H3560-S403-54-7620, 09/05 10-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 888: Optipoint 410 / Optipoint 410 S And Optipoint 420 / Optipoint 420 S

    (Session Initiation Protocol) protocol. The SIP protocol is an ASCII based signal protocol that is used to set up sessions in an IP network. The following features are available with HiPath 3000/5000 V6.0: – Hold – Consultation hold – Toggle P31003-H3560-S403-54-7620, 09/05 10-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 889 410 / optipoint 410 S and optiPoint 420 / optiPoint 420 S – Call deflection – Screened transfer – Mute – Music on hold – List of answered calls – Number redial – Speed dialing P31003-H3560-S403-54-7620, 09/05 10-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 890: Ip Telephony (Voice Over Ip)

    Versions 5.0 and later incorporate H.323 gatekeeper functions in the HiPath 3000 communi- cation system and in the HiPath ComScendo Service (integrated on HiPath 5000). This means that each HiPath 3000 system with at least one HG 1500 card and each HiPath ComScendo Service forms a separate gatekeeper zone, to which the registered IP workpoint clients also belong.
  • Page 891 No payload resources are required for direct transfer between IP-supported networks. A HiPath 5000 with HiPath ComScendo Service can function as the VoIP system. In systems with just one HG 1500 board, this board functions both as a signaling gateway and a media gateway.
  • Page 892: Optipoint 410 And Optipoint 410 S Telephones

    8 function keys with LEDs ● 2 volume adjustment keys (plus/minus) and pitch ● Suitable for wall mounting ● No modularity (no connecting capability for adapters or add-on devices), no display ● P31003-H3560-S403-54-7620, 09/05 10-40 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 893: Figure 10-18 Optipoint 410 Entry, Optipoint 410 Entry S - Standard Key

    Programmable Programmable Cancel Level Figure 10-18 optiPoint 410 entry, optiPoint 410 entry S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-41 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 894: Optipoint 410 Economy, Optipoint 410 Economy S

    Open listening ● 2 volume adjustment keys (plus/minus), pitch and display contrast ● Suitable for wall mounting ● No modularity (no connecting capability for adapters or add-on devices) ● P31003-H3560-S403-54-7620, 09/05 10-42 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 895: Figure 10-19 Optipoint 410 Economy, Optipoint 410 Economy S - Standard

    Programmable Programmable Cancel Level Figure 10-19 optiPoint 410 economy, optiPoint 410 economy S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-43 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 896: Optipoint 410 Economy Plus, Optipoint 410 Economy Plus S

    Port for headset (121 TR 9-5) ● 2 volume adjustment keys (plus/minus), pitch and display contrast ● Suitable for wall mounting ● No modularity (no connecting capability for adapters or add-on devices) ● P31003-H3560-S403-54-7620, 09/05 10-44 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 897: Figure 10-20 Optipoint 410 Economy Plus, Optipoint 410 Economy Plus S - Standard

    Level Figure 10-20 optiPoint 410 economy plus, optiPoint 410 economy plus S - Standard Key As- signment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-45 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 898: Optipoint 410 Standard, Optipoint 410 Standard S

    2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast ● Modularity: ● – 2 option bays – 1 interface for up to 2 add-on devices Suitable for wall mounting ● P31003-H3560-S403-54-7620, 09/05 10-46 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 899: Figure 10-21 Optipoint 410 Standard, Optipoint 410 Standard S - Standard Key

    Programmable Programmable Cancel Level Figure 10-21 optiPoint 410 standard, optiPoint 410 standard S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-47 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 900: Optipoint 410 Advance, Optipoint 410 Advance S

    2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast ● Modularity: ● – 1 option bay – 1 interface for up to 2 add-on devices Suitable for wall mounting ● P31003-H3560-S403-54-7620, 09/05 10-48 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 901: Figure 10-22 Optipoint 410 Advance, Optipoint 410 Advance S - Standard Key

    Programmable Programmable Cancel Level Figure 10-22 optiPoint 410 advance, optiPoint 410 advance S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-49 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 902: Optipoint 420 And Optipoint 420 S Telephones

    Open listening ● 2 volume adjustment keys (plus/minus), pitch and display contrast ● Suitable for wall mounting ● No modularity (no connecting capability for adapters or add-on devices) ● P31003-H3560-S403-54-7620, 09/05 10-50 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 903: Figure 10-23 Optipoint 420 Economy, Optipoint 420 Economy S - Standard

    Programmable Programmable Cancel Level Figure 10-23 optiPoint 420 economy, optiPoint 420 economy S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-51 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 904: Optipoint 420 Economy Plus, Optipoint 420 Economy Plus S

    Port for headset (121 TR 9-5) ● 2 volume adjustment keys (plus/minus), pitch and display contrast ● Suitable for wall mounting ● No modularity (no connecting capability for adapters or add-on devices) ● P31003-H3560-S403-54-7620, 09/05 10-52 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 905: Figure 10-24 Optipoint 420 Economy Plus, Optipoint 420 Economy Plus S

    Level Figure 10-24 optiPoint 420 economy plus, optiPoint 420 economy plus S - Standard Key As- signment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-53 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 906: Optipoint 420 Standard, Optipoint 420 Standard S

    2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast ● Modularity: ● – 2 option bays – 1 interface for up to 2 add-on devices Suitable for wall mounting ● P31003-H3560-S403-54-7620, 09/05 10-54 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 907: Figure 10-25 Optipoint 420 Standard, Optipoint 420 Standard S - Standard Key

    Programmable Programmable Cancel Level Figure 10-25 optiPoint 420 standard, optiPoint 420 standard S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-55 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 908: Optipoint 420 Advance, Optipoint 420 Advance S

    2 volume adjustment keys (plus/minus), pitch, speaker quality and display contrast ● Modularity: ● – 1 option bay – 1 interface for up to 2 add-on devices Suitable for wall mounting ● P31003-H3560-S403-54-7620, 09/05 10-56 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 909: Figure 10-26 Optipoint 420 Advance, Optipoint 420 Advance S - Standard Key

    Programmable Programmable Cancel Level Figure 10-26 optiPoint 420 advance, optiPoint 420 advance S - Standard Key Assignment (Default) Refer to Section 10.3.4 for information on connection and startup. P31003-H3560-S403-54-7620, 09/05 10-57 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 910: Connection And Startup

    410/420 Administrator Manual – optiPoint 410 S/420 S Administrator Manual Download The manuals and tools referred to in this document are available for download at http://www.si- emens.com/hipath (–> Downloads). P31003-H3560-S403-54-7620, 09/05 10-58 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 911: Connections On The Bottom Of The Telephone

    410, 420 standard S optiPoint 410, 420 advance, optiPoint 410, 420 advance S Figure 10-27 optiPoint 410, optiPoint 420, optiPoint 410 S, optiPoint 420 S - Connection Op- tions P31003-H3560-S403-54-7620, 09/05 10-59 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 912 Ethernet (10/100BaseT) interface (self-configuring) for the PC Headset (121 TR 9-5) Adapter 1 Adapter 2 USB interface No local power supply is required if power is provided via the Ethernet cable (Power over LAN). P31003-H3560-S403-54-7620, 09/05 10-60 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 913: Optipoint 410 / Optipoint 410 S And Optipoint 420 / Optipoint 420 S

    (one line with 12 characters) in which the function or call number currently saved is shown. Figure 10-28 optiPoint Self Labeling Key Module P31003-H3560-S403-54-7620, 09/05 10-61 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 914: Optipoint 410 Display Module

    Local personal telephone directory ● Access to company-wide telephone directory via LDAP ● WAP browser ● Voice-controlled dialing ● Call list containing all incoming and outgoing calls ● Speed-dialing list ● P31003-H3560-S403-54-7620, 09/05 10-62 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 915 The connection to the telephone is made over an interface cable with the following connectors: input MW6, output MW8. The power supply is ensured via the connected telephone. P31003-H3560-S403-54-7620, 09/05 10-63 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 916: Possible Configurations For The Add-On Devices

    420 standard optiPoint application module optiPoint self labeling key module optiPoint 420 advance Configuration with two optiPoint BLFs only with HiPath 3800, HiPath 3750, and HiPath 3700 P31003-H3560-S403-54-7620, 09/05 10-64 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 917: Use Of Optipoint 500 Adapters

    Acoustic Adapter ● Note: Floating contacts are not supported when using the adapter on optiPoint 410/opti- Point 410 S and optiPoint 420/optiPoint 420 S. optiPoint Recorder Adapter ● P31003-H3560-S403-54-7620, 09/05 10-65 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 918 P0/E In CorNet IP mode (IP interface, 10/100BaseT): WAP access ● Supported standards: H.323, Hicom Feature Access, G.711, G.723.1, QoS, SNMP, HTTP, DHCP, FTP, LDAP (database access I/F) P31003-H3560-S403-54-7620, 09/05 10-66 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 919: Optipoint 600 Office

    E headset adapter needed for headset connection Graphic LCD display with background lighting, LCD display without background lighting, no touchscreen touchscreen Supports card reader/writer Supports card reader P31003-H3560-S403-54-7620, 09/05 10-67 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 920: Table 10-8 Comparison Of Optipoint 600 Office And Optiset E Memory

    Connection of optiPoint 600 office over the IP interface: You can obtain further information ● in the installation and startup instructions (http://www.siemens.com/hipath (–> Down- loads)). Use HiPath 3000 Manager E to configure a workpoint client. P31003-H3560-S403-54-7620, 09/05 10-68 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 921: Optilog 4Me

    The optiLog 4me can be connected between the optiPoint 500 telephone and the handset. The privacy module is supplied complete with a local power supply. For additional information on this, please refer to the installation and administration instructions included with the adapter. P31003-H3560-S403-54-7620, 09/05 10-69 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 922: Optiset E Privacy Module

    The privacy module is supplied complete with a local power supply. The optiset E privacy module may be subject to import and export regulations. > P31003-H3560-S403-54-7620, 09/05 10-70 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 923: Optipoint Accessories

    Line voltage: 220 (230) Vac ● AC line frequency: 47 ... 53 Hz ● Output voltage: Max. 50 Vdc, min. 30 Vdc ● Output current: Max. 250 mA ● P31003-H3560-S403-54-7620, 09/05 10-71 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 924 "digital" device jack HiPath 3750 From optiPoint 500 adapter (for example, here the optiPoint analog adapter) optiPoint 500 Telephone Figure 10-32 Example of an External AC Adapter Connection P31003-H3560-S403-54-7620, 09/05 10-72 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 925 Output voltage max. 43 VDC, max. 43 VDC, max. 43 VDC, min. 30 VDC min. 30 VDC min. 30 VDC Output current 480 mA 480 mA 480 mA P31003-H3560-S403-54-7620, 09/05 10-73 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 926: Figure 10-33 Example Of A Corded And A Cordless Headset

    Note: A headset key can be configured for optiPoint or optiset E telephones. This allows the user to take calls and to toggle between the handset and the headset. Figure 10-33 Example of a Corded and a Cordless Headset P31003-H3560-S403-54-7620, 09/05 10-74 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 927 410 advance, optiPoint 410 advance optiPoint 420 economy plus, optiPoint 420 economy plus S optiPoint 420 standard, optiPoint 420 standard optiPoint 420 advance, optiPoint 420 advance optiset E basic P31003-H3560-S403-54-7620, 09/05 10-75 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 928 Accepting and ending calls using the headset keys is only supported if the connection is established using an optiPoint acoustic adapter. Information on connecting the headset is provided in the relevant installation instructions. P31003-H3560-S403-54-7620, 09/05 10-76 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 929: Opticlient 130 V5.0

    Use HiPath 3000 Manager E to configure a workpoint client for HiPath 3000/5000. optiClient 130 V5.0 software can be upgraded automatically. This can be started on a user-spe- cific basis during login, cyclically or can be skipped. P31003-H3560-S403-54-7620, 09/05 10-77 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 930: Hipath Ap 1120

    Information on connecting and configuring the HiPath AP 1120 terminal adapter can be ob- tained from the Installation Manual (Configuration Tools and Documentation) and the Adminis- tration Manual (http://www.siemens.com/hipath (–> Downloads)). P31003-H3560-S403-54-7620, 09/05 10-78 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 931: Attendant Console Versions

    500 standard - Standard Key Assignment (Default) for optiPoint At- tendant For more information, please refer to the optiPoint Attendant operating instructions (see Section 1.6, “Information on the Intranet”: Electronic Documentation on Com ESY Products). P31003-H3560-S403-54-7620, 09/05 10-79 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 932: Opticlient Attendant

    Selection of telephone directories: ● – Outlook Contacts – HiPath telephone directory – Internal Attendant telephone directory, based on Microsoft Access – LDAP on Microsoft Active Directory Server P31003-H3560-S403-54-7620, 09/05 10-80 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 933 Sorting of the busy lamp field or parts of the busy lamp field according to call number or alphabetically – Name definition for BLFs – Definition of titles for groups of busy lamp field stations P31003-H3560-S403-54-7620, 09/05 10-81 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 934 Note: The control of the network-wide busy signal via the optiClient Attendant is independently of the network-wide busy signal to the workpoints clients via the HiPath 5000 RSM Presence Manager.
  • Page 935 USB port on the PC. For operation using optiset E control adapters: optiset E telephone with free adapter slot ● and a free port on the PC (COM port 1-4). P31003-H3560-S403-54-7620, 09/05 10-83 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 936 Information on installation can be found in the Readme file on the optiClient Attendant product software CD. More information can be found in the optiClient Attendant operating instructions (see Section 1.6, “Information on the Intranet”: Electronic Documentation on Com ESY Products). P31003-H3560-S403-54-7620, 09/05 10-84 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 937: Mobile Telephones For Hipath Cordless Office

    Talk time: up to 13 hours Dimensions (L × W × D in mm): 147 × 54 × 26 ● Weight (including battery cells): approx. 130 g ● P31003-H3560-S403-54-7620, 09/05 10-85 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 938: Gigaset Sl1 Professional

    Dimensions (L × W × D in mm): 114 × 47 × 22 ● Weight (including battery cells): approx. 100 g ● Operating temperature (mobile telephone): +5 °C to +45 °C (41 °F to 113 °F) ● P31003-H3560-S403-54-7620, 09/05 10-86 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 939: Gigaset M1 Professional

    Dustproof – Break- and shockproof – Silicon-free interface – Sturdy carry clip Interference resistance conforming to EN 50 082-2 (industry standard) ● Acoustics optimized for industrial environments ● P31003-H3560-S403-54-7620, 09/05 10-87 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 940: Gigaset Active M

    Modified key layout (for use with protective gloves) – Illuminated display – Silicon-free interface – Sturdy carry clip Interference resistance conforming to EN 50 082-2 (industry standard) ● Acoustics optimized for industrial environments ● P31003-H3560-S403-54-7620, 09/05 10-88 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 941: Gigaset Active Ex

    Modified key layout (for use with protective gloves) – Silicon-free interface – Sturdy carry clip Interference resistance conforming to EN 50 082-2 (industry standard) ● Acoustics optimized for industrial environments ● P31003-H3560-S403-54-7620, 09/05 10-89 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 942 Dimensions (L × W × D in mm): 160 × 55 × 25 ● Weight (including battery cells): approx. 160 g ● Operating temperature (mobile telephone): –10 °C to +40 °C (14 °F to 104 °F) ● P31003-H3560-S403-54-7620, 09/05 10-90 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 943: Logging Mobile Telephones On To The System

    (such as 125) The login window remains open for ten minutes per station. The handset must log on during this period (refer to Page 10-92). P31003-H3560-S403-54-7620, 09/05 10-91 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 944: Logging On The Mobile Telephone

    After logging on and releasing a handset, always turn on the out-of-range warning signal. For more information, refer to the operating instructions (see Section 1.6, “Information on the Intra- net”: Electronic Documentation on Com ESY Products). P31003-H3560-S403-54-7620, 09/05 10-92 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 945: Checking The Login Status Of The Mobile Telephones

    (PIN) in the HiPath 3000system. This automatically logs off the mo- bile telephone. This also prevents a person who knows the old PIN to log on an invalid mobile tele- phone. P31003-H3560-S403-54-7620, 09/05 10-93 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 946: Analog Telephones For Hipath 3000

    It is also possible to connect an analog telephone to an existing optiPoint 500 tele- > phone with the optiPoint Analog Adapter (except for optiPoint 500 entry and optiPoint 500 economy). P31003-H3560-S403-54-7620, 09/05 10-94 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 947: Isdn Terminals For Hipath 3000

    It is also possible to connect an ISDN device to an existing optiPoint 500 telephone > using an optiPoint ISDN Adapter (except for optiPoint 500 entry and optiPoint 500 economy). P31003-H3560-S403-54-7620, 09/05 10-95 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 948 Workpoint Clients ISDN Terminals for HiPath 3000 P31003-H3560-S403-54-7620, 09/05 10-96 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 949: Hipath Cordless Office

    Technical Data for Base Stations, page 11-4 Power-Related Capacity Limits, page 11-6 Multi-SLC and System-Wide Networking, page 11-10 Planning Notes for Networked HiPath 3000 Systems Featuring Network-Wide Roaming, page 11-12 P31003-H3560-S403-54-7620, 09/05 11-1 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 950: Introduction

    (see Section 11.6). The HiPath 3000 product line does not currently support the network-wide handover feature. P31003-H3560-S403-54-7620, 09/05 11-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 951: System Configuration

    The B channels in the base station BS4 require a license (see Chapter 8). Up to 128 handsets are possible at an SLC16N. Up to 128 MTs are possible at an SLCN. P31003-H3560-S403-54-7620, 09/05 11-3 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 952: Technical Data For Base Stations

    - 5 to + 50 - 20 to + 45 Relative humidity – – – up to 95% BS3/1 base station Figure 11-1 BS3/1 S30807-H5482-X Base Station P31003-H3560-S403-54-7620, 09/05 11-4 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 953: Figure 11-2 Bs3/1 (Bs3/S) And Bs3/3 In The Outdoor Cover S30122-X7469-X

    Figure 11-2 BS3/1 (BS3/S) and BS3/3 in the Outdoor Cover S30122-X7469-X For information on the various outdoor cover mounting options, refer to the HiPath Cordless Of- fice Service Manual. P31003-H3560-S403-54-7620, 09/05 11-5 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 954: Power-Related Capacity Limits

    Connected to SLC16N HiPath 3750 Number of Number of base stations Number of HiPath 3700 SLC16N SLA24N BS3/1 BS2/2 SLMO24 BS3/3 connected via connected via P0/E P0/E Expansion cabinet P31003-H3560-S403-54-7620, 09/05 11-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 955 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50 P0/E CBCC or CBRC optiset E and optiPoint 500 telephones P31003-H3560-S403-54-7620, 09/05 11-7 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 956 Maximum number of corded telephones of BS2/2s analog telephones 1 - 10 11 - 20 21 - 30 31 - 40 41 - 50 SLC16N optiset E and optiPoint 500 telephones P31003-H3560-S403-54-7620, 09/05 11-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 957 The internal power supply unit in the respective system is the main power source for the base stations. For more information on the various power supply options, please refer to Page 3-160. P31003-H3560-S403-54-7620, 09/05 11-9 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 958: Multi-Slc And System-Wide Networking

    Handover from home to home – cordless board Handover from home to current-lo- cation cordless board Handover from current-location to current-location cordless board (temporary) (1 for each cordless board) P31003-H3560-S403-54-7620, 09/05 11-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 959 Networked HiPath 3000 systems feature max. 64 networked systems ● accessible using a shared station number (roaming among the systems/nodes) ● call interruption when changing between systems/nodes ● P31003-H3560-S403-54-7620, 09/05 11-11 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 960: Figure 11-4 Incorrect Dect Configuration Of Networked Hipath 3000 Systems

    , IP) HiPath 3000 System 1 HiPath 3000 System 2 DECT ID = 4711 DECT ID = 4711 Figure 11-4 Incorrect DECT Configuration of Networked HiPath 3000 Systems P31003-H3560-S403-54-7620, 09/05 11-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 961 , IP) HiPath 3000 System 1 HiPath 3000 System 2 DECT ID = 4711 DECT ID = 4711 Figure 11-6 Correct DECT Configuration when Networking HiPath 3000 Systems P31003-H3560-S403-54-7620, 09/05 11-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 962 HiPath Cordless Office Planning Notes for Networked HiPath 3000 Systems Featuring Network-Wide Roaming P31003-H3560-S403-54-7620, 09/05 11-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 963: Service

    Diagnosis Options, page 12-23 ● HiPath 3000 Error Messages (Entries in the Eventlog for HiPath 3000), page 12-48 ● HiPath 5000 Error Messages (Event Viewer Entries for HiPath 5000), page 12-57 ● Correcting Errors, page 12-70: Automatic Error Correction, page 12-70 ●...
  • Page 964 Controlled Release of a Remote Connection, page 12-77 ● Remote Administration and Access Using PPP, page 12-77 ● Security Features, page 12-79: Access Security, page 12-79 ● Automatic Logging of Administration Procedures, page 12-86 ● P31003-H3560-S403-54-7620, 09/05 12-2 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 965: Service And Maintenance Tasks

    Regardless of the volume of changes to the database, HiPath 3000 always automatically per- forms a complete CDB backup at midnight, system-time. P31003-H3560-S403-54-7620, 09/05 12-3 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 966 ● The directory in which the two PDS files are to be stored must be defined when the HiPath 5000 software is installed (setup). The two PDS files are created when the HiPath 5000 is started for the first time.
  • Page 967: Manual Customer Data Backup With Hipath 3000

    Menu 28 -> Edit CDB Menu 28-2 -> Back up CDB data Menu 28-2-2 -> CDB from MMC Caution: When performing this action, the system performs a hard restart. P31003-H3560-S403-54-7620, 09/05 12-5 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 968: Customer Data Backup With Hipath Software Manager

    The V.24 baud rate is set up. ● The ACD login port is configured. ● All telephone options, such as volume and display, are determined per ● station. P31003-H3560-S403-54-7620, 09/05 12-6 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 969 CMI mobile telephones again, ● reset the V.24 baud rate, ● re-configure the ACD login port, ● redefine all telephone configurations, such as volume and display, per ● station. P31003-H3560-S403-54-7620, 09/05 12-7 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 970: Effects Of Hardware Changes On Customer Data

    If the number is already assigned to a different object, you can switch both numbers. Replacing board with Board is activated. The same station range is used. same or under equipped board type P31003-H3560-S403-54-7620, 09/05 12-8 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 971 If you initiate a system reload on a system updated as described above, the system > must be reset after the updated CDB has been installed. The reset synchronizes the port placement sequence in the system with that of the CDB. P31003-H3560-S403-54-7620, 09/05 12-9 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 972: Exchanging Workpoint Clients

    With the HiPath 3000 Manager E, you can delete the add-on devices that are not plugged in and remove the keys that are no longer available. P31003-H3560-S403-54-7620, 09/05 12-10 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 973: Relocate/Transfer Application Processor Software (Aps)

    HiPath 3000 systems without HiPath Software Manager and ● HiPath 3000 systems with HiPath Software Manager. ● For networked HiPath 3000 systems with HiPath 5000 RSM, an APS update can only be per- formed with HiPath Software Manager. 12.2.3.1 APS Replacement/Transfer for HiPath 3000 Systems Without HiPath Software Manager Two memory areas are reserved for the application processor software on the MMC.
  • Page 974: Aps Transfer

    In case of power outage, the SDRAM content that has no battery backup and the active APS are completely lost. By re-accessing the current APS on the MMC, the system can be restored to the state it was in prior to the power outage. P31003-H3560-S403-54-7620, 09/05 12-12 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 975 The system software uses a special system reset (none of the other resets initiate a ● changeover) to change over to the new APS. You cannot use the telephone while the system resets and boots up. P31003-H3560-S403-54-7620, 09/05 12-13 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 976 APS on the MMC is deactivated. This does not impede switching traffic. The deactivated area is now available for a new APS transfer. The positive or negative entry in the error memory is sent to the service center. P31003-H3560-S403-54-7620, 09/05 12-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 977 An upgrade may also include modifications to hardware as well as error cor- rections. A software upgrade changes the name of the version, for example, from V1.0 to V2.0. A CDB conversion may be necessary. P31003-H3560-S403-54-7620, 09/05 12-15 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 978: Manager

    LAN. All HiPath 3000 systems must be able to access this HiPath 3000/5000 TFTP server over IP. Other TFTP servers cannot be used for HiPath Soft- ware Manager. P31003-H3560-S403-54-7620, 09/05 12-16 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 979: Upgrading Hipath 3000

    Service Service and Maintenance Tasks 12.2.4 Upgrading HiPath 3000 For information on upgrade procedures, please see Section 9.3, “Upgrading HiPath 3000 to V6.0”. P31003-H3560-S403-54-7620, 09/05 12-17 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 980: Determining System Information And Installed Software Components

    This should always be done before an update/ upgrade, for example. Further details on how to determine the system information using HiPath Inventory Manager can be obtained from the help provided with this tool. P31003-H3560-S403-54-7620, 09/05 12-18 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 981: Backing Up System Components (Backup Manager)

    A user account (user name, password) with write permission for the network drive must be specified for this type of backup. If the backup source (for example HiPath 5000) is located on a separate PC, this user ac- count must have read permission for the shared drive.
  • Page 982 The other system components are restored using HiPath 3000 Manager E (for HiPath 3000) and HiPath 3000 Manager I (for HG 1500 up to and including V2.0) or Web-based management WBM (for HG 1500 V3.0 or later). P31003-H3560-S403-54-7620, 09/05 12-20 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 983: Hipath User Management (Not Yet Released)

    The Small Remote Site concept requires that branch systems and the central system are con- nected via an IP network. It is not possible to integrate HiPath 5000 PCs with HiPath ComScen- do Service. System clients (IP workpoint clients) such as optiPoint 410 (not optiPoint 410 en- try), optiPoint 420 and optiClient 130 V5.0 are supported.
  • Page 984 ● Refer to the HiPath User Management service and administrator documentation for > information on the installation and configuration procedures for HiPath 3000/5000 and HiPath 3000 Element Manager. P31003-H3560-S403-54-7620, 09/05 12-22 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 985: Guided Maintenance

    The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm. Options available? You can call up the following options using the HiPath 3000 Manager E: ● ● ● IMODN ● P31003-H3560-S403-54-7620, 09/05 12-23 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 986: Power Supplies

    ● Board disabled ● Board enabled (active) ● Board busy (at least one station or line from this board is disconnected, is being called, or ● is busy). P31003-H3560-S403-54-7620, 09/05 12-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 987 All peripheral boards are equipped with LEDs for displaying the status of a board or port. Infor- mation on the meaning of the individual LED statuses can be found in the descriptions of indi- vidual boards in Chapter 3. P31003-H3560-S403-54-7620, 09/05 12-25 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 988: Recording Hipath 3000 Trunk Status

    Incoming call – Outgoing call – Trunk-to-trunk connection – Trunk disabled (using lockout switch or HiPath 3000 Man- ager E) – Trunk failure Number of the connected station ● P31003-H3560-S403-54-7620, 09/05 12-26 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 989: Recording Station Status

    Internal: Call forwarding activated only for internal ● calls. External: Call forwarding activated only for external ● calls. All: Call forwarding activated for all calls. ● Destination Number of call forwarding destination P31003-H3560-S403-54-7620, 09/05 12-27 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 990: Recording The Status Of The Hipath 3000 V.24 Interfaces

    The failure and restart of a V.24 interface generates an entry in the eventlog and releases a remote error signal (V.24 failure = “Check printer” error message, V.24 restart = Withdrawal of error message). P31003-H3560-S403-54-7620, 09/05 12-28 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 991: Trace Options For Hipath 3000

    Tracing call-specific activities You can trace all activities that were initiated by a call for telephones, trunks, etc. These include consultation calls, conference calls, and hunt groups, for example. P31003-H3560-S403-54-7620, 09/05 12-29 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 992: Hipath Manager Pcm Trace Monitor For Hipath 5000

    12.3.1.6.1 HiPath Manager PCM Trace Monitor Applications Communication between the different HiPath 5000 applications is organized using various buff- er tables and messages. You can monitor the individual entries in the different buffer tables, ex- changed immediate messages, program and communication messages for the relevant com- ponent in a separate trace window, in other words, a separate window is opened for each component (application).
  • Page 993: Starting And Exiting The Trace Monitor

    Trace Monitor The Trace Monitor can be closed with Exit in the File menu, with the key combination H + D or with the Trace Monitor system menu. P31003-H3560-S403-54-7620, 09/05 12-31 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 994: The Screen Layout Of The Trace Monitor

    Trace Monitor sys- Minimize tem menu Menu bar Trace window sys- tem menu Workspace (open trace win- dows) Status bar Figure 12-2 The Screen Layout of the Trace Monitor P31003-H3560-S403-54-7620, 09/05 12-32 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 995: Table 12-5 Trace Monitor Menu Functions

    Displays the trace windows side by side. Tile Horizontally Displays the trace windows one above the other. Arrange Icons Arranges the trace windows reduced to an icon. About... Activates Trace Monitor program information. P31003-H3560-S403-54-7620, 09/05 12-33 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 996: General Functions

    New trace messages are loaded to the buffer, but are no longer displayed. To disable this option, select the menu item Stop Window Scrolling again. The option is re- moved and recent messages are displayed. P31003-H3560-S403-54-7620, 09/05 12-34 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 997: Exporting Trace Windows

    (right-click in the Trace window) of the relevant Trace window. A message box containing the path and file name of the swap file for the trace window ap- pears: Confirm the message with OK. P31003-H3560-S403-54-7620, 09/05 12-35 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 998 Example of a file name for a swapped-out trace file Windows User: Meier Application: GetAccount Exported on: 06.09.2004 at: 16:57: C:\Documents and Settings \Meier \My Documents \WACLIENT \WACLIENT200409061657.trc P31003-H3560-S403-54-7620, 09/05 12-36 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 999: Testing Telephones

    The phone number, date and time are normally shown in the display. If a different text appears (“Gateway not found”, for example), this means that there is an error. Correct the error by following the administration instructions for the relevant telephone. P31003-H3560-S403-54-7620, 09/05 12-37 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual...
  • Page 1000: Event Viewer For Hipath 5000 (Eventlog)

    You can use it to display and administer eventlogs, to gather information on hard- ware and software problems, and to monitor security events. You can use this standard tool to obtain status information for the HiPath 5000 server and any application server present.

This manual is also suitable for:

Hipath 3000Hipath 3800