OPERATION

3.1

Preparation

WARNING:
OBSERVE SAFETY PRECAUTIONS STATED IN LOCAL ORDERS AND THE AIRCRAFT OR
EQUIPMENT SERVICING PROCEDURES.
Make sure the electrical and pneumatic connectors, electrical cables and pipes and positioning of
the ADTS 505 comply with the instructions and requirements in Section 2 Installation.
Carry out the following before use:
If necessary, carry out the maintenance task detailed in Section 4.
Make sure the air data test system power supply switch on the front panel is set to
OFF. Connect the air data test system to the electrical supply, make sure the supply
includes a connection to a protective earth.
Inspect the pneumatic hoses for damage, ingress of dirt and moisture. Make sure the
aircraft adaptors are serviceable and the pipe connections are air-tight.
Note: Do not connect the air data test system to a contaminated aircraft system. Inspect the static
vents and pitot probes for dirt and debris before connecting. If necessary, check the pitot-static
system water drain traps.
Connect, to the air data test system, the hoses necessary for the test procedures to be carried out:
STATIC output (Ps), PITOT output (Pt). Temporarily seal the free ends of the hoses.
Note:
When connected, take care not to kink or stand on the hoses.
Before use, the ADTS 505 should be tested, for first time users see section 3.4, for users requiring
more operating detail see section 3.5.
This section contains a quick reference chart detailing all the functions of the key-pad. Further
quick reference charts, at the end of this section, detail the set-up menu.
Review and become familiar with the whole procedure before starting the test process on an
aircraft or component.
3 - 1