Step 5 :
Assembly Case Brake
If the water supply stops after water is supplied for 5 seconds,
replace the Assembly Case Brake which is including Flow Meter.
Step 6 :
Water Valve (1)
Check the wiring connections to the water valve.
Check the Resistance of the water valve.
(Remove the connector before checking)
The Resistance : 1.2kΩ
If the value is not normal, Replace the Water valve.
Step 7 :
Water Valve (2)
Check for voltage value of the water valve during operation of water valve.
The Voltage value : approximately AC 120V
The Voltage value : approximately AC 120V
If the value is not normal, Replace the Main PBA.
Step 8 :
Assembly Case Sensor
If the water supply stops after water is supplied fully into the floater
in the assembly case sensor is located in High level sensor,
Replace the assembly case sensor which is
includes water (high & low) level sensor.