G.3.3: Type Codes For Monitor Modules - Honeywell nfs2-3030 Programming Manual

Fire alarm control panel
Hide thumbs Also See for nfs2-3030:
Table of Contents

Advertisement

Type Codes for Input Devices
Point Type
Type Code
supervisory
SUP T(PHOTO)*†
fire
SMOKE(DUCTP)
supervisory
SUP L(DUCTP)
supervisory
SUP T(DUCTP)†
fire
RFSMOKE(PHOTO)
fire
SMOKE(HARSH)
fire
SMOKE(LASER)
supervisory
SUP T (LASER)*†
supervisory
SUP L (LASER)*
fire
SMOKE(DUCTL)
supervisory
SUP L(DUCTL)
supervisory
SUP T(DUCTL)
fire
PHOTO/CO
fire
P/CO (P SUP)*
fire
P/CO (C SUP)
fire
AIR REF
Note: A reference detector still functions as a smoke detector, but the detector sensitivity level should be set to the least sensitive level—AL:9 and PA:9
Alarm and Pre-Alarm sensitivity. Refer to "Detector Sensitivity Settings" on page 124 for a complete list of detector sensitivity settings.
fire
HEAT
fire
HEAT+
fire
HEAT(FIXED)
fire
HEAT (ROR)
fire
SMOKE ACCLIM
fire
SMOKE(ACCLI+)
fire
SMOKE(MULTI)
fire
SMOKE(BEAM)
* Use only with approval of AHJ
† Not suitable for Canadian applications
‡ CLIP Mode only
G.3.3 Type Codes for Monitor Modules
Following is a list of monitor module Type Codes, which can be used to change the function of a
monitor module point.
Type Code
Point Type
MONITOR
fire alarm
NC MONITOR
fire alarm
NFS2-3030 Programming Manual — P/N 52545:K1 03/20/2012
Point Characteristics
Latching
Activates
(Y=yes
CBE
N=no)
N
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Table G.1 Intelligent Detector Type Codes (2 of 2)
Latching
Activates
(Y=yes
CBE
N=no)
Y
Y
Y
Y
Table G.2 Type Codes for Monitor Modules (1 of 3)
Device/Point Function
Photoelectric smoke detector
Duct Photoelectric smoke detector
Photoelectric smoke detector used as a duct detector to report
supervisory condition rather than alarm
Photoelectric smoke detector used as a duct detector to report
supervisory condition rather than alarm.
Wireless Photoelectric smoke detector
HARSH smoke detector
Laser smoke detector
Laser Smoke Detector
Laser Smoke Detector
Duct Laser smoke detector
Laser smoke detector used as a duct detector to report supervisory
condition rather than alarm.
Laser smoke detector used as a duct detector to report supervisory
condition rather than alarm.
Combination Photoelectric/CO detector
Combination Photoelectric/CO detector. Photo element activation
generates a supervisory condition.
Combination Photoelectric/CO detector. CO element activation
generates a supervisory condition.
Assign to one or more FSL-751detectors used to monitor the quality of
air entering the protected area. The air quality measurement allows the
VIEW system to compensate for vehicle fumes, fog, or other particles
brought into the protected area through the ventilation system. Poor air
quality will lower the sensitivity of all FSL-751 detectors on the SLC.
The detector sensitivity, however, remains within approved limits
(always less than 1% obscuration per foot).
o
190
F heat detector
o
190
F heat detector with low temperature warning
o
135
F intelligent thermal sensor
o
15
F per minute rate-of-rise detector
Combination Photoelectric/heat detector
Combination Photoelectric/heat detector with low temperature
warning, or Intelliquad FSC-851 Photoelectric Multi-Criteria Smoke
Sensor.
Multisensor smoke detector
Beam Smoke Detector
Point Characteristics
Device Function
Alarm-monitoring device
Alarm monitoring device, where an open circuit=active.
Type Codes
139

Advertisement

Table of Contents
loading

Table of Contents