CAUTION
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when
handling this equipment.
INSTALLATION

1. Unpack and inspect the equipment.

The following components should be included:
1 UIM-10/100
!
4 #6 Phillips Panhead Internal Locking Screws
!
2 #6 Phillips Beige Flathead Screws
!
If there is visible damage, do not attempt to connect the device; contact Customer Support at 1-877-
638-2638 (001-603-427-0600 for international customers) or support@nettonet.com.
2. Install the UIM-10/100.
Required tool for installation: Phillips screwdriver.
UIM Installation in an IP DSLAM
Affix the UIM to a Multiplexer Uplink Module (MUM).
NOTE
a. Place the MUM on a flat surface with the circuit board facing up.
b. Select a port on the MUM for UIM installation; either port (1 or 2) may be used.
220-0000016 rev01
UIM-10/100
Uplink Interface Module
The UIM may be attached to a MUM that has already been in service, although you must remove the
MUM from the IP DSLAM in order to do so. Removal of a MUM from an IP DSLAM chassis that is
powered up will not affect the operational status of other modules within the chassis; it
will, however, disengage the IP DSLAM's upstream network connection.
Although not required for operational purposes, if redundancy is desired, two UIMs
may be installed on the MUM, one in each port.

Installation Instructions

Advertisement

Table of Contents
loading

  Related Manuals for Net to Net Uplink Interface Module UIM-10/100

No related manuals

  Summary of Contents for Net to Net Uplink Interface Module UIM-10/100

  • Page 1: Installation Instructions

    CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling this equipment. INSTALLATION 1. Unpack and inspect the equipment. The following components should be included: 1 UIM-10/100 4 #6 Phillips Panhead Internal Locking Screws 2 #6 Phillips Beige Flathead Screws If there is visible damage, do not attempt to connect the device;...
  • Page 2 c. Remove the blanking plate* from the selected port. d. Carefully slide the faceplate of the UIM under the lip of the MUM faceplate at the selected port opening such that the UIM circuit board is facedown and the UIM label shows through the port opening with the model name along the right-hand edge.
  • Page 3 c. Remove the blanking plate* from the selected port. d. Carefully slide the faceplate of the UIM under the inside lip of the Mini DSLAM at the selected port opening such that the UIM circuit board is facedown and the UIM label shows through the port opening with the model name along the right-hand edge.
  • Page 4: Additional Information

    Additional Information LED Indicators LED State Indication solid green Fast Ethernet connection (100 Mbps) is established no Fast Ethernet illumination connection flashing Ethernet activity amber solid amber heavy traffic no Ethernet activity illumination solid green Ethernet connection is established no Ethernet connection illumination Regulatory Compliance The following regulatory compliance information applies to the UIM-10/100 as installed in a Mini...
  • Page 5 European Regulatory Compliance Information for Class A Equipment This Class A product complies with European Norm EN55022. Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation. 220-0000016 rev01 ©...