Yamaha CD-S3000 Service Manual page 38

Hide thumbs Also See for CD-S3000:
Table of Contents

Advertisement

CD-S3000
4. FACTORY PRESET
This menu is used to initialization of the back-up data.
4 - 1 . F _ P ?
Press the "LAYER" key.
LAYER キーを押します。
4 - 1 . F _ P D o n e
5. AD DATA CHECK
This menu is used to display the voltage value of the
microprocessor which detects protection functions of
this unit by using the sub-menu.
5-1. PRV_L
L channel power supply protection detection
Detected:
Detection port: 82 pin of main microprocessor
Normal value: 0.71 V to 2.84 V
*
If PRV_L becomes out of the normal value
range, the protection function works to turn
off the power.
38
4-1. FACTORY PRESET MENU
Initial display
初期表示
4-1. PRESET RESERVED (Initialization reserved) / PRESET RESERVED(初期化予約)
Initialization of the back-up data is reserved. (Actual initialization is executed when the power is
turned on next.) To reset to the original factory settings or user memory, select this sub-menu and
set the "STANDBY/ON / OFF" (Power) (U, K, A, B, G, L, V models) / " " (Power) (T model) switch
to the "OFF" position to turn off the power.
バックアップデータの初期化が予約されます。 (実際に初期化されるのは、 次回の電源投入時です。 )
工場出荷時やユーザーメモリをリセットしたいときは、こちらを選択してから STANDBY/ON /
OFF (電源)スイッチを OFF にして電源を切ってください。
+12VL, -12VL, +5VL, +3.3VL,
AC_L
(IC404 on DIGITAL P.C.B.)
5 - 1 . P _ L : 1 . 8 0
4. FACTORY PRESET
バックアップデータの初期化をします。
5. AD DATA CHECK
プロテクションを検出しているマイコンの電圧値が、
サブメニューで表示されます。
5-1. PRV_L
L チャンネルの電源電圧プロテクションの検出
検出先:
+12VL、-12VL、+5VL、+3.3VL、
AC_L
検出ポート: メインマイコン(DIGITAL P.C.B. の
IC404)の 82 ピン
正常値:
0.71 V ∼ 2.84 V
※ PRV_L が正常値を外れるとプロテクションが
働き、電源が切れます。

Advertisement

Table of Contents
loading

Table of Contents