Paradyne BitStorm IP DSLAM 1900 Installation And Maintenance Manual

Ip dslam
Table of Contents

Advertisement

Quick Links

BitStorm
1900 IP DSLAM
Installation and Maintenance Guide
Document No. 1900-A2-GN20-00
July 2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BitStorm IP DSLAM 1900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Paradyne BitStorm IP DSLAM 1900

  • Page 1 BitStorm ™ 1900 IP DSLAM Installation and Maintenance Guide Document No. 1900-A2-GN20-00 July 2002...
  • Page 2 Paradyne worldwide office locations, use one of the following methods: Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
  • Page 3 Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. All installation and service must be performed by qualified service personnel, as opening or removing covers may expose you to dangerous high voltage points or other risks. 3.
  • Page 4 The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation. CANADA – EMI NOTICE: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
  • Page 5: Table Of Contents

    Table of Contents About This Document Focus and Audience ........ix Related Documents .
  • Page 6 Table of Contents 10 Mbps CO Modem Card Specifications ....1-11 10306 CO Modem Card ....... . 1-11 10224 CO Modem Card .
  • Page 7 Task 024: Configuring the MIU ......2-72 Task 025: Configuring Remote Management ....2-87 Task 026: Testing the BitStorm 1900 Installation .
  • Page 8 Table of Contents Appendix B. Cabling Specifications Cable Connections and Specifications .....B-115 10306 Modem Card Cabling ......B-116 10224 Modem Card Cabling .
  • Page 9 List of Figures Figure 1-1: BitStorm 1900 Shelf with Cards and Components ....... . 1-2 Figure 1-2: BitStorm 1900 with 10306 Modem Cards (Part #: 01-00153-01) .
  • Page 10 List of Figures Figure 2-21: Voice/Data System Test Points..........2-97 Figure 2-22: Data-only System Test Points.
  • Page 11 List of Tables Table 1-1: CO Modem Card LEDs ... 1-6 Table 1-2: Same Card Broadcast Feature Enabled/Disabled Function for CO Modems ... 1-7 Table 1-3: System Power Specifications with 10306 CO Modem ... 1-13 Table 1-4: System Power Specifications with 10224 CO Modem ... 1-18 Table 1-5: Power Specifications for the AC Fan Tray ...
  • Page 12 List of Tables viii BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 13: About This Document

    BitStorm 1900 IP DSLAM. Related Documents Documentation for BitStorm and EtherLoop products is available online at www.paradyne.com. Select Library –> Technical Manuals –>BitStorm DSL Systems or GrandVIEW / StormTracker EMS. Other supporting documentation for the BitStorm 1900 includes: •...
  • Page 14: Conventions

    About This Document • Conventions The following conventions have been used in preparing this documentation. Safety Labels Throughout this document the following labels will be displayed to indicate safety issues. Make sure to read the labels carefully to ensure your own personal safety as well as that of equipment and customer services.
  • Page 15 Software Steps and Procedures • • 1900-A2-GN20-00 DANGER: POSSIBLE PERSONAL INJURY! This label means there is a possibility of personal bodily injury. Text you are required to type or enter will appear in the document as follows: <ENTER>, Name, <Tab>, programs\seven\aa1 Text displayed on a computer screen will appear as follows: “From the HyperTerminal window, select File/ Properties, then select the Settings tab.”...
  • Page 16 About This Document BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 17: Bitstorm 1900 Ip Dslam

    1. BitStorm 1900 IP DSLAM Introduction The BitStorm 1900 utilizes patented EtherLoop technology to provide a robust platform that supports lifeline Plain Old Telephone Service (POTS) in addition to a variety of new revenue- generating services ranging from simple high-speed Internet access to advanced quality video conferencing, multi-stream Video On Demand (VOD), IP multicast video, and toll-quality Voice over IP (VolP).
  • Page 18: Bitstorm 1900 Shelf

    1. BitStorm 1900 IP DSLAM Figure 1-1: BitStorm 1900 Shelf with Cards and Components MIU Card Power Card Blank Filler Card BitStorm 1900 Shelf The BitStorm 1900 Shelf supports 60 to 240 EtherLoop lines. Each BS1900 Shelf contains 13 card slots housing the following circuit packs: •...
  • Page 19: Air Baffle

    The BitStorm 1900 shelf and components are installed in a standard 19” rack and can be installed in 23” racks using optional 23” mounting ears. Up to five (5) BS1900 Systems can be installed into one rack depending on the application and the associated required components. Refer to "Appendix B.
  • Page 20: Filter 66-Block Option

    1. BitStorm 1900 IP DSLAM The following table provides information on some common configurations and the number of Filter Shelves required for each installation. Ten 10224 CO Modem Cards Ten 10306 CO Modem Cards Filter 66-Block Option The Filter 66-Block provides the same POTS splitter function as the Filter Shelf;...
  • Page 21 The following table compares the number of BS1900 systems that can be installed into a standard 7’ rack using the Filter Shelf or Filter 66- Block options: Configuration 10306 CO Modem Cards 10224 CO Modem Cards The remainder of this chapter covers features of the BitStorm System and the CO modem card and component specifications.
  • Page 22: Co Modem Cards

    1. BitStorm 1900 IP DSLAM CO Modem Cards One BitStorm 1900 shelf supports up to 10 modem cards. Each CO modem card controls the StormPort CPE modems, directing data traffic flow between the CPE modems and the data network. The following CO modem cards are available: •...
  • Page 23: Same Card Broadcast

    computer’s MAC address is entered into the Privacy Management filter table. NOTE: Same Card Broadcast The Same Card Broadcast feature is an option on CO modems that should be used in conjunction with Privacy Management to provide secure communications (default is Disabled): Refer to Table 1-2, “Same Card Broadcast Feature Enabled/Disabled Function for CO Modems,”...
  • Page 24: Spectrum Manager Adsl Protect

    1. BitStorm 1900 IP DSLAM Spectrum Manager ADSL Protect The Spectrum Manager software makes EtherLoop spectrally compatible with asymmetrical services such as ADSL and G.Lite, detecting and protecting against interference within the same binder. In addition, EtherLoop in its native state is spectrally compatible with symmetrical digital services such as T1, HDSL, HDSL2, or SDSL.
  • Page 25: Passes Vlan Tagged Frames

    A list of all supported MIBs and the private MIB can be found in document 1900-A2-GK40, BitStorm 1900 IP DSLAM Supported SNMP MIBs. This document and private MIBs can be downloaded from the Paradyne website at www.paradyne.com. 1900-A2-GN20-00 MIU (Management Interface Card) – supports 10306 and 10224...
  • Page 26: Mixing Co Modem Cards

    1. BitStorm 1900 IP DSLAM Mixing CO Modem Cards It is possible to fill a BitStorm 1900 shelf with different modem cards (i.e., five 10306 CO modem cards, and five 10224 CO modem cards). For the 10306 CO modem cards, Spectrum Manager includes a Video Protect mode that protects EtherLoop heavy downstream traffic from disrupting upstream traffic on adjacent EtherLoop lines.
  • Page 27: 10 Mbps Co Modem Card Specifications

    10 Mbps CO Modem Card Specifications 10306 CO Modem Card The 10306 CO modem card provides six EtherLoop lines, each with its own dedicated 10 Mbps modem. Special Features • • • • • 1900-A2-GN20-00 WARNING: POSSIBLE EQUIPMENT DAMAGE! To comply with Telcordia GR-1089-CORE, Outside Plant Voltage/Current Limiting Protection is required for each Outside Plant...
  • Page 28: Figure 1-2: Bitstorm 1900 With 10306 Modem Cards (Part #: 01-00153-01)

    1. BitStorm 1900 IP DSLAM Figure 1-2: BitStorm 1900 with 10306 Modem Cards (Part #: 01-00153-01) 10306 CO Modem Specifications Description Shelf Interface WAN Interface Line Interface Heat Dissipation LEDs Card Dimensions Operation Temperature Short-term Operat- ing Temperature: Certifications Power Supply Fan Tray 1-12 BitStorm 1900 Installation and Maintenance Guide...
  • Page 29: 10306 Co Modem Ip Multicast Operation

    Table 1-3: System Power Specifications with 10306 CO Modem Power Bit Storm 1900 Configuration 260 W DC power supply 260 W AC power supply * Configuration assumes 10 modem cards are used. 10306 CO Modem IP Multicast Operation An optional feature of the 10306 CO modem card is the ability to pass IP Multicast traffic only to the subscribing port.
  • Page 30: Figure 1-3: 10306 Ip Multicast Operation

    1. BitStorm 1900 IP DSLAM Figure 1-3: 10306 IP Multicast Operation 02-17164 1-14 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 31 The 10306 IP Multicast Operation works in the following manner: 1. The client issues an IGMP Join Request (Unsolicited report) 2. The 10306 modem listens for any IGMP packets (IGMP snooping) 3. The 10306 forwards the IGMP Join Request upstream through the 4.
  • Page 32: 10224 Co Modem Card

    1. BitStorm 1900 IP DSLAM 10224 CO Modem Card The 10224 CO modem card provides 24 statistically multiplexed EtherLoop lines; 12 per single 10 Mbps modem. NOTE: 1-16 BitStorm 1900 Installation and Maintenance Guide The 10224 is recommended for use on loops up to 6000’ long. WARNING: POSSIBLE EQUIPMENT DAMAGE! To comply with Telcordia GR-1089-CORE, Outside Plant Voltage/Current Limiting...
  • Page 33: Figure 1-4: Bitstorm 1900 With 10224 Modem Cards (Part #: 01-00164-01)

    Figure 1-4: BitStorm 1900 with 10224 Modem Cards (Part #: 01-00164-01) 10224 CO Modem Specifications Description Shelf Interface 100Base-T Ethernet Bus WAN Interface Line Interface Dual 35-pin Omni Grid connector Heat Dissipation 12 watts LEDs Power, Link, Data Transfer (2 lights) Card Dimensions 12”...
  • Page 34: Table 1-4: System Power Specifications With 10224 Co Modem

    1. BitStorm 1900 IP DSLAM Table 1-4: System Power Specifications with 10224 CO Modem Power Bit Storm 1900 Configuration 260 W DC power supply 260 W AC power supply * Configuration assumes 10 modems cards are used. 1-18 BitStorm 1900 Installation and Maintenance Guide Modem # Lines Power...
  • Page 35: Wan Interface Card Specifications

    Rock’s SNMPc to manage the MIU and EtherLoop modems. The SNMP MIBs, including MIB II RFC 1213 and the EtherLoop MIB, are listed in document 1900-A2-GK40, BitStorm 1900 IP DSLAM Supported SNMP MIBs. MIBs are available from the Paradyne website at www.paradyne.com. 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide 1.
  • Page 36: Figure 1-5: Bitstorm 1900 With Miu (Part #: 01-00075-01) And 10306 Co Modems

    1. BitStorm 1900 IP DSLAM Figure 1-5: BitStorm 1900 with MIU (Part #: 01-00075-01) and 10306 CO Modems MIU CO Modem Specifications Description Shelf Interface 10/100Base-T Ethernet Bus WAN Interface 50 Pin AMP Ethernet Pass-Thru, 10Base T-X Craft Interface RS-232 RJ11 (DB9 to RJ11 connector and cable included) Heat Dissipation 4 watts...
  • Page 37: Figure 1-6: Miu Data Connection

    BitStorm ™ Server B I T S T Software *Server can be Applications co-located or remote Site Manager Spectrum Manager Etc. TCP/IP Layer 2/3 Switch 17 18 19 20 LINK/ACT LINK/ACT LINK/ACT 100Mb/s 100Mb/s 100Mb/s LINK/ACT LINK/ACT LINK/ACT 100Mb/s 100Mb/s 100Mb/s 21 22 34 24 Management Commands...
  • Page 38: Power Card Specifications

    1. BitStorm 1900 IP DSLAM Power Card Specifications The power cards convert the power feeds to the +12, +5, +3.3, -5 and +2.5 V DC power levels used by the BitStorm 1900 components. 260 W DC The 260 W DC power card converts the -48 V DC power feed to the power levels used by the 10306 and 10224 CO modem cards.
  • Page 39: Figure 1-7: 260 W Dc Power Card (Part #: 01-00080-01)

    Figure 1-7: 260 W DC Power Card (Part #: 01-00080-01) 260 W DC Power Card Specifications Description Card Dimensions 12” x 2.27” x 11.75” LEDs -48V, DC Power, Supply Alarm, Fuse Alarm Input -48V DC (Refer to Table 1-3, “System Power Specifications with 10306 CO Modem,”...
  • Page 40 1. BitStorm 1900 IP DSLAM 260 W AC The 260 W AC power card converts the 110/220 V AC power feed to the power levels used by the 10603 and 10224 CO modem cards and the MIU. Application: Required with 10306 and 10224 CO modem cards with AC power supply.
  • Page 41: Figure 1-8: 260 W Ac Power Card (Part #: 01-00079-01)

    Figure 1-8: 260 W AC Power Card (Part #: 01-00079-01) 260 W AC Power Card Specifications Description Card Dimensions 12” x 2.27” x 11.75” LEDs 12V DC, 5 V DC, 3.3V DC,-5 V DC Input 85 – 265 V AC, 47 – 63 Hz Cord IEC 320, (6’) Operating...
  • Page 42: Fan Tray Specifications

    1. BitStorm 1900 IP DSLAM Fan Tray Specifications The -48V DC fan tray and the 110/220V AC (switch selectable) fan tray are used with the BitStorm 1900 in EtherLoop applications to provide forced-air cooling in each chassis. A fan tray is required under each chassis that houses one or more 10306 or 10224 CO modem cards.
  • Page 43: Table 1-5: Power Specifications For The Ac Fan Tray

    Table 1-5: Power Specifications for the AC Fan Tray Power Bit Storm 1900 Configuration AC Fan Tray 1900-A2-GN20-00 WARNING: POSSIBLE EQUIPMENT DAMAGE! AC Fan Trays are shipped with an air filter frame. To ensure proper airflow, the frame must be installed.
  • Page 44: Fan Tray -48 V Dc

    1. BitStorm 1900 IP DSLAM Fan Tray -48 V DC Figure 1-10: Fan Tray -48 V DC (Part #: 01-00084-01) Audible Alarm Table 1-6: Power Specifications for the DC Fan Tray Power Bit Storm 1900 Configuration DC Fan Tray 1-28 BitStorm 1900 Installation and Maintenance Guide Fan Failure LEDs Fan Tray -48 V DC Specifications...
  • Page 45: Low-Pass Filter Specifications

    Low-Pass Filter Specifications Filter Shelf Low-Pass filters are used with the BitStorm 1900 in EtherLoop applications where voice service is required. The low-pass filter cards separate out-of-voiceband signals from the voiceband traffic between the BitStorm modems and the external voice facility equipment. The Low-Pass Filter Shelf contains one filter card for every two 10306 modem cards, or two filter cards for every 10224 modem card.
  • Page 46: Front Panel

    1. BitStorm 1900 IP DSLAM Figure 1-11: Filter Shelf (Filter Shelf Part #: 01-20029-01, Filter Card Part #: 01-20029-01, and Filter 66-Block Part #: 05-00021-01) Front Panel Filter 66-Block 1-30 BitStorm 1900 Installation and Maintenance Guide Filter Shelf Specifications Shelf Dimensions 5.25”...
  • Page 47: Bitstorm 1900 Component Requirements

    BitStorm 1900 Component Requirements Table 1-7, “BitStorm 1900 Component Requirements,” provides the basic requirements for each component within the shelf. 1900-A2-GN20-00 Table 1-7: BitStorm 1900 Component Requirements Part Shelf Number Components 01-00080-01 260 W DC power 01-00079-01 260 W AC power 01-00075-01 01-00084-01...
  • Page 48 1. BitStorm 1900 IP DSLAM 1-32 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 49: Bitstorm 1900 Installation And Testing

    2. BitStorm 1900 Installation and Testing The BitStorm 1900 provides EtherLoop CO modems, which communicate with the remote StormPort CPE modems installed at the customer premises. Installing the BitStorm 1900 consists of the following: • • • • NOTE: In voice/data applications, the BitStorm 1900 shelf installation includes This chapter contains the procedures for installing and testing the mid- mount and flush-mount components of the BitStorm 1900.
  • Page 50: Installation Flowchart

    2. BitStorm 1900 Installation and Testing Installation Flowchart Figure 2-1, "BitStorm 1900 Installation Flowchart." provides a visual flowchart of the BitStorm 1900 installation process as a reference tool. Figure 2-1: BitStorm 1900 Installation Flowchart Start Verify Install Rack Rack and Space, Connect to Power and...
  • Page 51: Installation Task List

    Installation Task List The following is a complete list of all tasks to perform. To install the BitStorm 1900 complete each task in the order given. Task 001: Pre-Installation Checklist Task 002: Installing the 19” Fan Tray Task 003: Installing the BS1900 and Filter Shelves Task 004: Installing the Air Baffle Task 005: Installing the Circuit Packs Task 006: Connecting Power to the Shelf...
  • Page 52: Task 001: Pre-Installation Checklist

    2. BitStorm 1900 Installation and Testing Task 001: Pre-Installation Checklist Before installing the BitStorm 1900 system, verify that the following steps have been completed: Step Installation hardware kit supplied with shelf Phillips-head screwdriver (#1 or #2) Anti-static protection such as a grounded wrist strap Volt-ohm meter PC with serial port to configure MIU Cross-connect punch-down tool...
  • Page 53 Step STOP 1900-A2-GN20-00 Procedure Verify all necessary BS 1900 system components, hardware, circuit packs, and cables are at the installation site and that they are in good condition. If a Materials List is provided, verify the packing list with it. Determine if an AC or DC power card is to be used in the configuration.
  • Page 54: Task 002: Installing The 19" Fan Tray

    2. BitStorm 1900 Installation and Testing Task 002: Installing the 19” Fan Tray The 19" fan tray is necessary for a chassis housing one or more 10306 or 10224 CO modem cards. The fan tray is installed under each BS1900 shelf and contains six forced-air cooling fans to ensure sufficient cooling for operation.
  • Page 55: Figure 2-2: Fan Tray Mounting

    Step NOTE: This is the opposite of how non-telecommunications electronics are NOTE: The power supply for the multiplexer must also be -48 V DC. 1900-A2-GN20-00 Procedure Figure 2-2: Fan Tray Mounting Mid-Mount Connect power for -48 V DC. (If you are installing an AC fan tray, proceed to step 3 to connect power for the 110 V AC fan tray.) a.) The -48 V DC connection requires a 14-gauge stranded cable (not included).
  • Page 56: Figure 2-3: -48 V Dc Fan Tray

    2. BitStorm 1900 Installation and Testing Step NOTE: The power supply for the multiplexer must also be 110/220 V AC. 2-40 BitStorm 1900 Installation and Maintenance Guide Procedure Figure 2-3: -48 V DC Fan Tray Connect power for the 110/220 V AC fan tray. a.) Connect the power cord to the IEC terminal connection on the front panel.
  • Page 57 Step NOTE: An air filter must be installed and maintained in the DC Fan Tray for NOTE: Installed air filters must be changed every 6 months. Bulk packs of STOP 1900-A2-GN20-00 Procedure Install the air filter frame. a.) The filter must be removed. b.) Slide the frame into place.
  • Page 58: Task 003: Installing The Bs1900 And Filter Shelves

    2. BitStorm 1900 Installation and Testing Task 003: Installing the BS1900 and Filter Shelves Use this procedure to install the BitStorm 1900 modem shelf and filter shelf. NOTE: The filter shelf is not required in data-only applications. Requirements This procedure requires the following: •...
  • Page 59 Step 1900-A2-GN20-00 Procedure Select and apply grounded anti-static protection. WARNING: ELECTROSTATIC DISCHARGE! Anti-static protection required! The BitStorm 1900 shelves are shipped with the circuit packs installed. When handling any circuit pack, you must wear grounded anti-static protection. The discharge of static electricity can damage the circuit packs.
  • Page 60: Figure 2-5: Bitstorm 1900 Modem Shelves Mounted In Bay

    2. BitStorm 1900 Installation and Testing Figure 2-5: BitStorm 1900 Modem Shelves Mounted in Bay Mid-Mount Flush-Mount 02-17177 Using the shelf mounting screws provided in the shelf hardware kit, fasten the left and right flanges to the bay as shown in Figure 2-6, "BitStorm 1900 Shelf Fastened to Bay,"...
  • Page 61: Figure 2-6: Bitstorm 1900 Shelf Fastened To Bay

    Step 1900-A2-GN20-00 Procedure Figure 2-6: BitStorm 1900 Shelf Fastened to Bay Shelf Mounting Screw (4) Shelf Ground Stud Side Flange Proceed according to the following table: If the application is Voice/data Align and mount a filter shelf directly above the Bit- Storm 1900 shelf as shown in Figure 2-7, "Filter Shelf Mounting in Bay,"...
  • Page 62: Figure 2-7: Filter Shelf Mounting In Bay

    2. BitStorm 1900 Installation and Testing Step Procedure (continued) Figure 2-7: Filter Shelf Mounting in Bay Filter Shelf 5.25" x 17.5" x 11.75" BS1900 Shelf 12.1875" x 17.5" x 12" Mid-Mount Flush-Mount 02-17179 STOP <RX KDYH FRPSOHWHG WKLV WDVN 2-46 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 63: Task 004: Installing The Air Baffle

    Task 004: Installing the Air Baffle Use this procedure to install the BitStorm 1900 Air Baffle. Requirements This procedure requires the following: • Step STOP 1900-A2-GN20-00 Phillips-head screwdriver (#1 or #2) Procedure Verify that the mounting adapters are in the same position as the BS 1900 and the Filter Shelf (i.e., mid-mount or flush-mount).
  • Page 64: Task 005: Installing The Circuit Packs

    2. BitStorm 1900 Installation and Testing Task 005: Installing the Circuit Packs Use this procedure to install the BitStorm 1900 circuit packs. Requirements This procedure requires the following: • Step STOP 2-48 BitStorm 1900 Installation and Maintenance Guide Grounded anti-static protection WARNING: ESD (ELECTROSTATIC DISCHARGE) ! Anti- static protection required! When handling any circuit pack, you must wear grounded...
  • Page 65: Task 006: Connecting Power To The Shelf

    Task 006: Connecting Power to the Shelf Use this procedure to install the power feeds from a -48 V DC or 110 V AC power source to the BitStorm 1900 modem shelf. NOTE: The filter shelf does not require a power feed. Requirements This procedure requires the following: •...
  • Page 66 2. BitStorm 1900 Installation and Testing Step Black 2-50 BitStorm 1900 Installation and Maintenance Guide Procedure With the power supply turned OFF, connect the -48 V DC (260W) or 110 V AC (260W) power source according to the following table and Figure 2-8, "Typical DC Power Harness Connection to -48 V DC (260W) Power Source,"...
  • Page 67: Figure 2-8: Typical Dc Power Harness Connection To -48 V Dc (260W) Power Source

    Step Figure 2-8: Typical DC Power Harness Connection to -48 V DC (260W) Power Source Single Power Source BLACK LEAD V dc Return Positive ( + ) Terminal NOTE: If using a -48 V DC power supply, use an appropriate volt-ohm meter to 1900-A2-GN20-00 Procedure Power Supply #1...
  • Page 68: Figure 2-9: Typical Power Connection To 260W Ac Power Source

    2. BitStorm 1900 Installation and Testing Step NOTE: The redundant power supply sources connect to two pairs of wires on 2-52 BitStorm 1900 Installation and Maintenance Guide Procedure the BitStorm 1900’s power harness and are electrically the same. Route the other end of the DC power harness to the DC power connector on the backplane of the BitStorm 1900 modem shelf.
  • Page 69 Step STOP 1900-A2-GN20-00 Procedure Secure the power harness in accordance with local office procedures. 10.) Turn ON the power to the shelf from the power supply. <RX KDYH FRPSOHWHG WKLV WDVN BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) 2-53...
  • Page 70: Table 2-1: Data Cable Selection For Miu Shelf Processor

    2. BitStorm 1900 Installation and Testing Task 007: Installing the Data Network Connection with an MIU Use this procedure to connect the BitStorm 1900 to the Ethernet data network using an MIU. Requirements This procedure requires the following: • • •...
  • Page 71: Figure 2-10: Bitstorm 1900 Data Connection Via Miu

    Step Figure 2-10: BitStorm 1900 Data Connection via MIU BitStorm ™ Server Layer 2/3 Switch LINK/ACT 100Mb/s LINK/ACT 100Mb/s 1900-A2-GN20-00 Procedure Figure 2-10 shows a typical EtherLoop data network connection with the BitStorm 1900 using an MIU. Hospitality /VBN B I T S T SERVER Carrier 17 18 19 20...
  • Page 72: Figure 2-11: Miu Card With Cable Connections

    2. BitStorm 1900 Installation and Testing Step 2-56 BitStorm 1900 Installation and Maintenance Guide Procedure Connect the 50-pin connector to the Ethernet Pass-Thru port, then connect the cables at the other end to the corresponding switch(es). Refer to Figure 2-11 (shown below). Connect the RJ-11 cable with the adapter (DB9S to RJ-11) to the local craft terminal (PC/laptop).
  • Page 73 Step STOP 1900-A2-GN20-00 Procedure Proceed according to the following table: If the application is GO TO: "Task 008: Installing Voice/Data & Filter Shelf Connections, on page 58." Voice/data "Task 009: Installing Voice/Data w/Filter 66- Block Connections, on page 64." GO TO: Data-only "Task 010: Installing the Data-only Connections, on page 67."...
  • Page 74 2. BitStorm 1900 Installation and Testing Task 008: Installing Voice/Data & Filter Shelf Connections Use this procedure to connect the BitStorm 1900 to the EtherLoop cross-connect in voice/data applications. Requirements This procedure requires the following tools and materials: • • •...
  • Page 75: Table 2-2: Pin And Pair Assignments For The Champ To Omni Grid Cable (Part #: 04-00007-10)

    Step Table 2-2: Pin and Pair Assignments for the Champ to Omni Grid Cable (Part #: 04-00007-10) From From With Color Code Conn Pin # Pair # BLU/WHT OR/WHT GR/WHT BR/WHT SLT/WHT BLU/RED OR/RED GR/RED BR/RED SLT/RED BLU/BLK OR/BLK GR/BLK BR/BLK SLT/BLK BLU/YEL...
  • Page 76 2. BitStorm 1900 Installation and Testing Step 2-60 BitStorm 1900 Installation and Maintenance Guide Procedure Connect one Amp-Champ connector of an intermediate cable to the "Line/CPE" side of the EtherLoop cross-connect block, then connect the other end to an Amp-Champ to Dual Omni Grid cable. Connect the Amp-Champ connector of the second intermediate cable to the "Voice"...
  • Page 77: Figure 2-12: Line/Cpe And Voice Connections On The Filter Shelf For 10306 Modem Cards

    Step Figure 2-12: Line/CPE and Voice Connections on the Filter Shelf for 10306 Modem Cards 1900-A2-GN20-00 Procedure Amp Champ to Dual Omni Grid Cable part # 04-00007-10 Interconnect Cable #1 IN *Not Used BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) Interconnect Cable #1 OUT...
  • Page 78: Figure 2-13: Line/Cpe And Voice Connections On The Filter Shelf For 10224 Modem Cards

    2. BitStorm 1900 Installation and Testing Step Figure 2-13: Line/CPE and Voice Connections on the Filter Shelf for 10224 Modem Cards Dial Tone IN from PBX/PSTN Dial Tone & EtherLoop OUT EtherLoop from BitStorm shelf 2-62 BitStorm 1900 Installation and Maintenance Guide Procedure Male Amp Champ to...
  • Page 79 2. BitStorm 1900 Installation and Testing Step Procedure (continued) Go to "Task 011: Installing External Voice Switch Connections, on page 70." STOP <RX KDYH FRPSOHWHG WKLV WDVN 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide 2-63...
  • Page 80 2. BitStorm 1900 Installation and Testing Task 009: Installing Voice/Data w/Filter 66-Block Connections Use this procedure to connect the BitStorm 1900 to the EtherLoop cross-connect in applications where voice/data service is required with a Filter 66-Block. Requirements This procedure requires the following tools and materials: •...
  • Page 81: Figure 2-14: Voice/Data Filter 66-Block Connections For 10306 Co Modems

    Step Figure 2-14: Voice/Data Filter 66-Block Connections for 10306 CO Modems 1900-A2-GN20-00 Procedure BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) Amp Champ to Dual Amp Champ Cable part # 04-00029-01 Amp Champ to Dual Omni Grid Cable part # 04-00007-10 *Not Used 02-17186...
  • Page 82: Figure 2-15: Voice/Data Filter 66-Block Connections For 10224 Co Modems

    2. BitStorm 1900 Installation and Testing Step Figure 2-15: Voice/Data Filter 66-Block Connections for 10224 CO Modems STOP 2-66 BitStorm 1900 Installation and Maintenance Guide Procedure *Not Used <RX KDYH FRPSOHWHG WKLV WDVN (continued) Amp Champ to Dual Omni Grid Cable part # 04-00007-10 02-17187 1900-A2-GN20-00...
  • Page 83: Task 010: Installing The Data-Only Connections

    Task 010: Installing the Data-only Connections Use this procedure to connect the BitStorm 1900 to the EtherLoop cross-connect in applications where no voice service is required. Requirements This procedure requires the following tools and materials: • • • • "Appendix B. Cabling Specifications," on page 115 contains the complete specifications for the cables and wiring required in this procedure.
  • Page 84: Figure 2-16: Data-Only Connections On The 66-Block For 10306 Co Modem Cards

    2. BitStorm 1900 Installation and Testing Step Figure 2-16: Data-only Connections on the 66-Block for 10306 CO Modem Cards 2-68 BitStorm 1900 Installation and Maintenance Guide Procedure Figure 2-17, "Data-only Connections on the 66-Block for 10224 CO Modem Cards," on page 69. Record the EtherLoop assignments. Female Male (continued)
  • Page 85 Step Figure 2-17: Data-only Connections on the 66-Block for 10224 CO Modem Cards STOP 1900-A2-GN20-00 Procedure Female Male *Not Used <RX KDYH FRPSOHWHG WKLV WDVN BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) Male Amp Champ to Dual Omni Grid Cable part # 04-00007-10 02-17189...
  • Page 86 2. BitStorm 1900 Installation and Testing Task 011: Installing External Voice Switch Connections Use this procedure to connect the BitStorm 1900 lines to an external voice facility. Requirements This procedure requires the following tools and materials: • • "Appendix B. Cabling Specifications," on page 115 contains the specifications for the cables and wiring required in this procedure.
  • Page 87 2. BitStorm 1900 Installation and Testing Step Procedure (continued) Record the EtherLoop cross-connect Tip/Ring assignments for the voice facility according to local office procedures. STOP <RX KDYH FRPSOHWHG WKLV WDVN 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide 2-71...
  • Page 88: Task 012: Configuring The Miu

    2. BitStorm 1900 Installation and Testing Task 012: Configuring the MIU Complete the following steps to configure the MIU. Step 2-72 BitStorm 1900 Installation and Maintenance Guide Procedure Ensure that the BitStorm 1900 is powered on. Verify the PC has an ASCII terminal emulator loaded (i.e., Hyperterminal software, etc.).
  • Page 89 2. BitStorm 1900 Installation and Testing Step Procedure (continued) Figure 2-18: Craft Connection with the MIU Craft Cable CRAFT Connection MIU Card MIU Craft Cable (DB-9 with RJ-11 to RS-232 adapter) Craft Terminal 02-17190 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide 2-73...
  • Page 90: Figure 2-19: Com Port Settings

    2. BitStorm 1900 Installation and Testing Step 2-74 BitStorm 1900 Installation and Maintenance Guide Procedure Set the serial COM1 port terminal communication settings. a.) Initiate a Terminal Session using terminal emulation software (i.e., Hyperterminal). b.) Select the appropriate serial menu (i.e., COM1, COM2, etc). c.) Verify the port settings are the same as shown in Figure 2-19, "COM Port Settings."...
  • Page 91 Step NOTE: The Craft Interface is case-sensitive. Make sure to type all entries in 1900-A2-GN20-00 Procedure Craft Interface Login a d m i n for the default lowercase. The following screen displays requiring a Type e t h e r l o o p and press and password can be changed after the initial login).
  • Page 92: Table 2-3: Cli (Command Line Interface) Commands

    2. BitStorm 1900 Installation and Testing Step 2-76 BitStorm 1900 Installation and Maintenance Guide Procedure BS1900MIU>> For list of all available CLI commands, type BS1900MIU>> prompt and press This screen provides a list of the available commands to configure the MIU. Refer to the following table for a description of each com- mand.
  • Page 93 1900-A2-GN20-00 Table 2-3: CLI (Command Line Interface) Commands CLI Commands Command DATE Enter to change the date. HELP Enter to obtain additional help IFCONFIG Use to configure the MIU I.P. Address, Subnet Mask, Status, Default Gateway etc. MENU Enter to view the Main Menu for the interface. BitStorm 1900 Installation and Maintenance Guide 2.
  • Page 94 2. BitStorm 1900 Installation and Testing 2-78 BitStorm 1900 Installation and Maintenance Guide Table 2-3: CLI (Command Line Interface) Commands CLI Commands Command PING Enter to verify if an I.P. Address is valid. RESET Use to Reset or Reboot the system. (It is not advised to power down the system in order to perform a reset of the system.) SNMP...
  • Page 95 Step 1900-A2-GN20-00 Procedure Type at the BS1900MIU>> prompt. m e n u BitStorm 1900 MIU Craft Interface Main Menu displays. Configuration Type to select BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) 2-79...
  • Page 96 2. BitStorm 1900 Installation and Testing Step 2-80 BitStorm 1900 Installation and Maintenance Guide Procedure Configuration Menu 10.) From the Network Interface Configuration Type in the MIU Ethernet IP Address 11.) Ethernet Subnet Mask Gateway, and the to save the settings, then press Configuration Menu (continued) , type...
  • Page 97 Step 1900-A2-GN20-00 Procedure Set Time-of-Day Clock 12.) Type to select screen appears: 13.) Enter the current date and time. a.) Enter the current date in the format MMDDYYYY. [Enter only the numbers not the slashes (/). This screen is currently under construction.
  • Page 98 2. BitStorm 1900 Installation and Testing Step 2-82 BitStorm 1900 Installation and Maintenance Guide Procedure b.) After entering the 4-digit year, the cursor will automatically jump to the Time field. (This field is not marked in this version.) Enter the time as HHMMSS (Do not type the colon (:) between the numbers, plus signs (+) will separate the numbers.
  • Page 99 2. BitStorm 1900 Installation and Testing Step Procedure (continued) Change Username 15.) Type to select to modify the user name. The following screens display: 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide 2-83...
  • Page 100 2. BitStorm 1900 Installation and Testing Step 2-84 BitStorm 1900 Installation and Maintenance Guide Procedure 16.) Type a new user name, then press follow indicating that the user name has been saved). Press any User Account Administration key to return to the screen.
  • Page 101 Step 1900-A2-GN20-00 Procedure 19.) Once all of the configuration parameters are entered, the system must be reset for the changes to take effect. To reset the system, Utilities type to select BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) Main Menu from the...
  • Page 102 2. BitStorm 1900 Installation and Testing Step Procedure (continued) Reset System 20.) Type to select , and then to confirm. STOP <RX KDYH FRPSOHWHG WKLV WDVN 2-86 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 103: Task 013: Configuring Remote Management

    Task 013: Configuring Remote Management The MIU can be remotely managed via the management 10Base T-X Ethernet port as shown in Figure 2-20, "Telnet Connection for the BitStorm 1900." Figure 2-20: Telnet Connection for the BitStorm 1900 TELNET Connection Router Ethernet Switch LINK/ACT 100Mb/s...
  • Page 104: Step Procedure

    1900-A2-GK40, BitStorm 1900 IP DSLAM Supported SNMP MIBs. This document and private MIBs can be downloaded from the Paradyne website at www.paradyne.com. Using Telnet for Remote Provisioning and Management NOTE: Before using the Telnet option for remote management, the MIU must The following steps and procedures are provided to aide in configuring the MIU and setting the traps.
  • Page 105 Step 1900-A2-GN20-00 Procedure Type in the c o m m a n d prompt displays: At the DOS prompt type for the MIU, then press Login screen displays: BitStorm 1900 Installation and Maintenance Guide 2. BitStorm 1900 Installation and Testing (continued) Open: field and click...
  • Page 106 2. BitStorm 1900 Installation and Testing Step NOTE: The Craft Interface is case-sensitive. Make sure to type all entries in 2-90 BitStorm 1900 Installation and Maintenance Guide Procedure Type a d m i n for the default < E n t e r > lowercase.
  • Page 107 To verify this is the latest version, contact our Technical Support organization at www.paradyne.com. Type i f c o n f i g - L - 0 current MIU configuration information.
  • Page 108 2. BitStorm 1900 Installation and Testing Step 2-92 BitStorm 1900 Installation and Maintenance Guide Procedure If any of the information needs to be modified, type: i f c o n f i g - m 0 The screen above displays indicating you are connected remotely to the MIU and asks if you would like to change the the MIU.
  • Page 109 Step 1900-A2-GN20-00 Procedure 11.) To view the current SNMP parameters, type < E n t e r > 12.) Verify the correct Community Name Trap Target Addresses 13.) To edit the SNMP configuration information type BitStorm 1900 Installation and Maintenance Guide 2.
  • Page 110 2. BitStorm 1900 Installation and Testing Step Community Name Current Poll Interval Set Trap Targets 2-94 BitStorm 1900 Installation and Maintenance Guide Procedure 14.) From this screen changes to the Current Poll Interval can be made. Refer to the following table as a guide for these settings.
  • Page 111 Step NOTE: When logging back into the MIU, the new IP Address must be entered. STOP 1900-A2-GN20-00 Procedure 15.) If changes to the configuration have been made, the system must be reset. Type r e s e t Refer to Table 2-3, “CLI (Command Line Interface) Commands,” on page 76, for additional CLI commands for remote management.
  • Page 112: Task 014: Testing The Bitstorm 1900 Installation

    2. BitStorm 1900 Installation and Testing Task 014: Testing the BitStorm 1900 Installation Testing a BitStorm 1900 installation includes the following tasks: • • • The following sections contain testing-related information followed by the BitStorm 1900 testing tasks. Testing tasks for network support equipment such as LAN/WAN routers are not included in this document.
  • Page 113 Step Optional BitStorm ™ Server Hospitality /VBN B I T S T SERVER Layer 2/3 Switch Carrier 17 18 19 20 LINK/ACT LINK/ACT LINK/ACT POWER 100Mb/s 100Mb/s 100Mb/s LINK/ACT LINK/ACT LINK/ACT READY 100Mb/s 5 6 7 8 100Mb/s 21 22 34 24 100Mb/s BitStorm™...
  • Page 114 2. BitStorm 1900 Installation and Testing Step Optional BitStorm ™ Server Hospitality /VBN B I T S T SERVER Layer 2/3 Switch Carrier 17 18 19 20 LINK/ACT LINK/ACT LINK/ACT POWER 100Mb/s 100Mb/s 100Mb/s LINK/ACT LINK/ACT LINK/ACT READY 100Mb/s 100Mb/s 100Mb/s 5 6 7 8 21 22 34 24...
  • Page 115: Task 015: Testing Voice Connectivity

    Task 015: Testing Voice Connectivity This procedure checks the voice connectivity in BitStorm 1900 voice/ data applications. Requirements The following is required to do this procedure: • • • Step STOP 1900-A2-GN20-00 External voice facility point-of-presence equipment installed Tip/Ring assignments Standard telecommunications hand-test telephone set Procedure Identify the voice line being tested.
  • Page 116: Task 016: Testing Data Connectivity

    2. BitStorm 1900 Installation and Testing Task 016: Testing Data Connectivity This procedure checks data connectivity from the customer premise distribution frame and the BitStorm 1900 shelf. Requirements A StormPort Modem with power adapter and extension cord (if necessary) is required for this procedure. Step STOP 2-100...
  • Page 117: Task 017: Etherloop End-To-End Testing

    Task 017: EtherLoop End-to-End Testing This procedure checks the EtherLoop system installation, including simultaneous voice and data EtherLoop tests from the modem to the voice and data networks. Requirements The EtherLoop end-to-end system testing requires the following: • • • •...
  • Page 118 2. BitStorm 1900 Installation and Testing Step NOTE: The browser application must be configured for "no proxies." Refer to STOP 2-102 BitStorm 1900 Installation and Maintenance Guide Procedure “Chapter 3. BitStorm 1900 Maintenance” on page 103 for more information." In the browser application, enter the IP address of a known, working site on your network or on the Internet.
  • Page 119: Maintenance Guidelines

    3. BitStorm 1900 Maintenance This chapter contains guidelines and checklists for the maintenance of the BitStorm 1900 system. Maintenance Guidelines The following factors can cause service problems in an EtherLoop sys- tem installation: • • • • • The following sections briefly describe each of these potential problem causes.
  • Page 120: Bitstorm 1900 Equipment Installation

    3. BitStorm 1900 Maintenance Cable Connections It is important to ensure that all connections to the EtherLoop system are firmly seated and secured. An incomplete connection at any one point could cause the EtherLoop system to malfunction. BitStorm 1900 Equipment Installation BitStorm 1900 equipment is relatively simple to install.
  • Page 121: Voice/Data Connectivity Troubleshooting Checklist

    Maintenance Checklists Voice/Data Connectivity Troubleshooting Checklist No voice or data service Voice but no data service Data but no voice service 1900-A2-GN20-00 Table 3-1: Voice/Data Connectivity Maintenance in Facility Room Problem • Verify that the correct Tip/Ring pairs are being tested for both voice and data •...
  • Page 122: Table 3-2: End-To-End Maintenance Checklist

    3. BitStorm 1900 Maintenance End-to-End Maintenance Checklist 3-106 BitStorm 1900 Installation and Maintenance Guide Table 3-2: End-to-End Maintenance Checklist Problem • Verify power at all points in the system No voice or data service • Verify connections and wiring conditions at all points •...
  • Page 123: Bay Requirements And Specifications

    Appendix A. Installation Requirements This appendix describes the facility requirements for the BitStorm 1900 shelf and filter shelf. BitStorm 1900 Support Equipment Equipment and materials that must be installed to support the BitStorm 1900 shelf include the following: • • •...
  • Page 124: Bs1900 System Specifications

    Appendix A. Installation Requirements • • • BS1900 System Specifications Table A-1, "BitStorm 1900 System Specifications" shows the power specifications for the BitStorm 1900 shelf. Table A-1: BitStorm 1900 System Specifications Description Lines Per Chassis Weight Height Width Required Rack Units Depth Cabled Depth Cabled Ear to Front (Front Mount)
  • Page 125: Grounding Environment Specifications

    Table A-1: BitStorm 1900 System Specifications (continued) Description Connectors Dependencies Cable List Certifications 10306 configuration assumes a full chassis consisting of a 260 Watt AC Power Card, MIU and 10-10306 CO Cards. 10224 configuration assumes a full chassis consisting of a 260 Watt AC Power Card, MIU and 10-10224 CO Cards. Fan Trays The fan shelf provides forced-air cooling in the 7RU modem chassis and 3RU filter chassis.
  • Page 126: Cbn Grounding Environment

    Appendix A. Installation Requirements (IBN) environment. Either of these environments may use a 1/0 AWG ground collector. The following sections offer guidelines for each of these environments, with and without ground collectors. See local electrical codes or the appropriate IBDN standards for more information. CBN Grounding Environment In most facilities using the CBN environment, the bay containing the BitStorm 1900 shelf should be grounded to a frame ground bar (FGB)
  • Page 127: Bs1900 Component Installation Requirements

    • Network support requirements will vary according to the existing facility resources. We suggest using a site survey questionaire to ensure all requirements are identified. Paradyne Partners will find surveys on our Partners site at www.paradyne.com. BS1900 Component Installation Requirements Table A-2, "BitStorm 1900 Components"...
  • Page 128: Installation Tools And Materials

    Appendix A. Installation Requirements 01-30036-01 04-00007-10 04-00008-18 04-00028-01 03-00003-01 01-00085-01 01-00084-01 01-00084-02 Installation Tools and Materials The tools and materials required to install the BitStorm 1900 shelf include the following: • • • • • A-112 BitStorm 1900 Installation and Maintenance Guide Table A-2: BitStorm 1900 Components (continued) Part# BitStorm Component...
  • Page 129: Bitstorm 1900 Physical Characteristics

    BitStorm 1900 Physical Characteristics This section specifies the physical dimensions and weight of the BitStorm 1900 and filter shelves Table A-3, "BitStorm 1900 Weight and Dimensions" includes the shelf weight and dimensions. Installation Site Requirements Equipment Location The BitStorm 1900 should be isolated from other machinery and should have a minimum distance of 30 inches from UV lighting to prevent Electrostatic Discharge (ESD).
  • Page 130 Appendix A. Installation Requirements Local area network environment Power supply Environmental A-114 BitStorm 1900 Installation and Maintenance Guide Table A-4: BitStorm Operational Requirements Specification Layer 2 Ethernet -48 V DC nominal -46 to -56 V DC acceptable range or 110 V AC Operating temperature: C (41 Relative Humidity: 1% to 90%...
  • Page 131: Cable Connections And Specifications

    Appendix B. Cabling Specifications This appendix contains the specifications for the cabling used with the 10306 and 10224 modem cards in the BitStorm 1900 shelf. The illustrations associated with each of the modem card cabling sections show typical rack layouts. (These configurations change according to the particular implementation needs of the customer.) Cable Connections and Specifications This section includes cable connections and specifications for the...
  • Page 132: Modem Card Cabling

    Appendix B. Cabling Specifications 10306 Modem Card Cabling Refer to Figure B-1,“Cabling – Filter Shelf with 10306 Modem Cards,” on page 116, for the 10306 cable connections using a filter shelf and 66-Block. Figure B-2,“Cabling – Filter 66-Block with 10306 Modem Cards,”...
  • Page 133: Figure B-2: Cabling - Filter 66-Block With 10306 Modem Cards

    Figure B-2: Cabling – Filter 66-Block with 10306 Modem Cards Amp Champ to Dual Amp Champ Cable part # 04-00029-01 Amp Champ to Dual Omni Grid Cable part # 04-00007-10 1900-A2-GN20-00 24 Lines of Dial Tone 10306 2 RU FAN 2 RU AIR BAFFLE 10306 2 RU FAN...
  • Page 134: Modem Card Cabling

    Appendix B. Cabling Specifications 10224 Modem Card Cabling Figure B-3,“Cabling – Filter Shelf with 10224 Modem Cards,” on page 118, for 10224 cable connections using a filter shelf and 66- Block. Figure B-4,“Cabling – Filter 66-Block with 10224 Modem Cards,” on page 119, illustrates the connections for the 10224 modem cards using a Filter 66-Block.
  • Page 135: Bitstorm 1900 Cable Harness

    Figure B-4: Cabling – Filter 66-Block with 10224 Modem Cards Amp Champ to Dual Omni Grid Cable part # 04-00007-10 BitStorm 1900 Cable Harness Figure B-5 (on next page) illustrates the BitStorm 1900 cable assembly (DSUB50P to 10x RJ45). This cable connects the MIU card to the layer 2/3 switch.
  • Page 136: Decapus Cable

    Appendix B. Cabling Specifications Decapus Cable Layer 2/3 Switch B-120 BitStorm 1900 Installation and Maintenance Guide Figure B-5: Decapus Cable Connections MIU Connector Layer 2/3 Switch Connectors 17 18 19 20 LINK/ACT LINK/ACT LINK/ACT POWER 100Mb/s 100Mb/s 100Mb/s LINK/ACT LINK/ACT LINK/ACT 100Mb/s READY...
  • Page 137: Amp-Champ To Dual Amp Champ Cable

    Appendix B. Cabling Specifications AMP-Champ to Dual AMP Champ Cable The AMP Champ to Dual AMP Champ cable connects from the Filter 66-Block to an AMP Champ Omni Grid cable, which connects to the 10306 cards. Refer to Figure B-6 (shown below) and to Table B-1, “AMP-Champ to Dual AMP-Champ Cable Specifications,”...
  • Page 138: Table B-1: Amp-Champ To Dual Amp-Champ Cable Specifications

    Appendix B. Cabling Specifications Table B-1: AMP-Champ to Dual AMP-Champ Cable Specifications Conn1 Color Code of Cable 1 BL/W W/BL BR/W W/BR BL/R R/BL BR/R R/BR BL/BK BK/BL O/BK BK/O B-122 BitStorm 1900 Installation and Maintenance Guide Conn2 Conn1 Color Code of Conn3 Cable 2 G/BK...
  • Page 139: Amp Champ To Dual Omni Grid Cable

    Appendix B. Cabling Specifications AMP Champ to Dual Omni Grid Cable The AMP Champ to Dual Omni Grid cable is used to connect the Filter Shelf or Filter 66-Block with 10306 and 10224 CO modem cards to the AMP Champ to AMP Champ cable the cross connect. For 10306 and 10224 CO modem cards connecting to a Filter 66-Block, this cable connects to the AMP Champ to Dual AMP Champ cable.
  • Page 140: Table B-2: Amp Champ To Dual Omni Grid Cable Specifications

    Appendix B. Cabling Specifications Table B-2: AMP Champ to Dual Omni Grid Cable Specifications From From With Color Code Conn Pin # Pair # BLU/WHT OR/WHT GR/WHT BR/WHT SLT/WHT BLU/RED OR/RED GR/RED BR/RED SLT/RED BLU/BLK OR/BLK GR/BLK BR/BLK SLT/BLK BLU/YEL OR/YEL GR/YEL BR/YEL...
  • Page 141: Omni Grid To Dual Omni Grid

    Appendix B. Cabling Specifications Omni Grid to Dual Omni Grid The Omni Grid to Dual Omni Grid cable is used to connect the Filter Shelf to 10306 CO modem cards. Refer to Figure B-8 (shown below) and Table B-3, “Omni Grid to Dual Omni Grid Cable Specifications,” on page 126 for cable specifications.
  • Page 142: Table B-3: Omni Grid To Dual Omni Grid Cable Specifications

    Appendix B. Cabling Specifications B-126 BitStorm 1900 Installation and Maintenance Guide Table B-3: Omni Grid to Dual Omni Grid Cable Specifications Color BLU/WHT WHT/BLU OR/WHT WHT/OR GR/WHT WHT/GR BR/WHT WHT/BR GRY/WHT WHT/GRY BLU/RED RED/BLU OR/RED RED/OR GR/RED RED/GR BR/RED RED/BR GRY/RED RED/GRY BLU/BLK...
  • Page 143: Omni Grid To Omni Grid Cable

    Appendix B. Cabling Specifications Omni Grid to Omni Grid Cable The omni grid to omni grid cable connects the Filter Shelf to the 10224 CO modem cards. Refer to Figure B-9 (shown below) and Table B-4, “Omni Grid to Omni Grid Cable Specifications,” on page 128 for cable specifications.
  • Page 144: Table B-4: Omni Grid To Omni Grid Cable Specifications

    Appendix B. Cabling Specifications Table B-4: Omni Grid to Omni Grid Cable Specifications From From With Color Conn Pin # Pair # Code WHT/ WHT/ WHT/ WHT/BR WHT/ RED/ RED/OR RED/GR RED/BR RED/ BLK/ BLK/OR B-128 BitStorm 1900 Installation and Maintenance Guide From From Conn...
  • Page 145: Intermediate Cable Specifications

    Intermediate Cable Specifications BitStorm 1900 intermediate (loop extension) cables can be obtained "off-the-shelf" from a variety of vendors, as long as cables chosen meet the following specifications: • • Figure B-10 (shown below) illustrates an example of intermediate cabling suitable for use with the BitStorm 1900. 1900-A2-GN20-00 Category 5 bundled 25-pair cable made of 24-AWG wires Unshielded, 25-pair female connector (Amp-Champ or equivalent)
  • Page 146: Power Connector Terminations

    Appendix B. Cabling Specifications Power Cable Harness Figure B-11 (shown below) illustrates the BitStorm 1900 cable harness. The BitStorm 1900 power cable assembly connects the DC power source to the BitStorm 1900 shelf. One BitStorm 1900 power cable harness contains connectors to support three BitStorm 1900 shelves. Figure B-11: Power Cable Harness Mate-N-Lok Connector (4-prong)
  • Page 147 Appendix B. Cabling Specifications WARNING: POSSIBLE EQUIPMENT DAMAGE! Reversed polarities on the DC power feed can irreparably damage the BitStorm 1900 shelf components. Be certain power feeds are connected properly to the power source, with the red leads connected to the DC supply as shown in the table above.
  • Page 148 Appendix B. Cabling Specifications B-132 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 149: Appendix C. Craft Interface Screens

    Appendix C. Craft Interface Screens This appendix includes all of the Craft Interface screens available from the Main Menu. Main Menu 1900-A2-GN20-00 Figure C-1: Main Menu BitStorm 1900 Installation and Maintenance Guide C-133...
  • Page 150: Figure C-2: (A. Configuration) Configuration Menu

    Appendix C. Craft Interface Screens Configuration Figure C-2: (A. Configuration) Configuration Menu Figure C-3: (A. Configuration) A. Network Interface Configuration C-134 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 151: Figure C-4: (A. Configuration) B. Snmp Configuration Menu

    Appendix C. Craft Interface Screens Figure C-4: (A. Configuration) B. SNMP Configuration Menu Figure C-5: (A. Configuration, B. SNMP Configuration Menu) A. SNMP Trap/Polling Parameters 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide C-135...
  • Page 152: Figure C-6: (A. Configuration, B. Snmp Configuration Menu) B. Change Snmp Community Names

    Appendix C. Craft Interface Screens Figure C-6: (A. Configuration, B. SNMP Configuration Menu) B. Change SNMP Community Names Figure C-7: (A. Configuration) C. Set Time-of-Day Clock C-136 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 153: Figure C-8: B. Statistics Menu

    Appendix C. Craft Interface Screens Statistics Figure C-8: B. Statistics Menu Figure C-9: (B. Statistics) A. Network Layer Statistics 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide C-137...
  • Page 154: Figure C-10: (B. Statistics) B. Physical Layer Statistics Menu

    Appendix C. Craft Interface Screens Figure C-10: (B. Statistics) B. Physical Layer Statistics Menu Figure C-11: (B. Statistics, B. Physical Layer Statistics) A. Ethernet Port Statistics C-138 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 155: Figure C-12: (B. Statistics, B. Physical Layer Statistics) B. I2C Statistics

    Appendix C. Craft Interface Screens Figure C-12: (B. Statistics, B. Physical Layer Statistics) B. I2C Statistics Figure C-13: (B. Statistics) C. Environment Statistics 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide C-139...
  • Page 156: Figure C-14: (B. Statistics) D. System Memory Statistics

    Appendix C. Craft Interface Screens Figure C-14: (B. Statistics) D. System Memory Statistics Figure C-15: (B. Statistics) E. Shelf Extent Statistics C-140 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 157: Figure C-16: (B. Statistics) F. System Error-Reset Data

    Appendix C. Craft Interface Screens Figure C-16: (B. Statistics) F. System Error-Reset Data Figure C-17: (B. Statistics) G. Modex Daemon Run Statistics 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide C-141...
  • Page 158: User Account Administration

    Appendix C. Craft Interface Screens Firmware Version Information Figure C-18: C. Firmware Version Information User Account Administration Figure C-19: D. User Account Administration Menu C-142 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...
  • Page 159: Figure C-20: (D. User Account Administration) A. Change Remote Username

    Appendix C. Craft Interface Screens Figure C-20: (D. User Account Administration) A. Change Remote <TELENET> Username Figure C-21: (D. User Account Administration) B. Change Remote <TELENET> Password 1900-A2-GN20-00 BitStorm 1900 Installation and Maintenance Guide C-143...
  • Page 160: Utilities

    Appendix C. Craft Interface Screens Utilities Figure C-22: E. Utilities Menu Figure C-23: (E. Utilities) A. Reset Confirmation C-144 BitStorm 1900 Installation and Maintenance Guide 1900-A2-GN20-00...