Paradyne Hotwire ReachDSL 6350-A4 Installation Instructions Manual

With inline phone filter
Hide thumbs Also See for Hotwire ReachDSL 6350-A4:

Advertisement

Quick Links

®
Hotwire
ReachDSL
with Inline Phone Filter

Installation Instructions

Document Number 6350-A2-GN12-00
September 2001
Contents
......................................................................................................

Hotwire 6350 ReachDSL Modem Overview

®
The Hotwire
6350 ReachDSL
System and interoperates with the Hotwire 8312 or 8314 ReachDSL/MVL
Hotwire GranDSLAM (Digital Subscriber Line Access Multiplexer) system. This system
provides high-speed Internet or corporate LAN access over traditional twisted-pair
copper telephone wiring.
The ReachDSL technology:
T
Operates over existing copper wire with existing telephone jacks.
T
Utilizes an inline phone filter on the modem's PHONE jack.
T
Includes a second line pass-through from the ReachDSL modem's LINE jack to
PHONE jack to accommodate an attached 2-line telephone.
T
Provides adaptive data rates to dynamically adapt and allocate bandwidth to
optimize applications.
..............................................................................................
.............................................................................................
.................................................................................... 11
........................................................................ 16
Modem is a component in the Hotwire ReachDSL
Modem, Model 6350-A4
.................................................
............................................
.............................................. 10
............................................... 13
1
..................... 15
...................................... 22
®
1
4
5
7
9
Card in the

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hotwire ReachDSL 6350-A4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Paradyne Hotwire ReachDSL 6350-A4

  • Page 1: Table Of Contents

    Operates over existing copper wire with existing telephone jacks. Utilizes an inline phone filter on the modem’s PHONE jack. Includes a second line pass-through from the ReachDSL modem’s LINE jack to PHONE jack to accommodate an attached 2-line telephone. Provides adaptive data rates to dynamically adapt and allocate bandwidth to optimize applications.
  • Page 2: Hotwire Reachdsl System

    — A telephone is used to represent any equipment that plugs into a phone jack and uses the POTS line, such as a phone, modem, or fax machine. — End-user system is used to represent any PC with an Ethernet connection and ReachDSL-based service.
  • Page 3: Product-Related Documents

    6040-A2-GN11 Hotwire 6040 MVL Wall Jack Phone Filter Installation Instructions Contact your sales or service representative to order additional product documentation. Paradyne documents are available on the World Wide Web at www.paradyne.com. Select Library Technical Manuals Hotwire DSL & MVL Systems.
  • Page 4: Getting Started

    Getting Started Before beginning your modem’s installation, make sure that you have all the equipment that you need. Package Checklist Verify that your package contains the following: Hotwire 6350 ReachDSL Modem DSL interface cable with RJ11 connectors Power cord with power transformer Be sure to register your warranty at www.paradyne.com/warranty.
  • Page 5: Installing The Hotwire 6350 Reachdsl Modem

    Installing the Hotwire 6350 ReachDSL Modem Place the Hotwire 6350 ReachDSL Modem on a flat surface with clearance for the rear connectors. Procedure 1. If a telephone is connected at the RJ11 wall jack where the modem will be installed, unplug the telephone line from the wall jack.
  • Page 6 4. Use an 8-pin Ethernet cable for the Ethernet connection. Insert one end of the cable into the jack labeled ETHERNET. — Use a straight-through cable and connect the other end to an Ethernet hub. (To connect to a hub’s Uplink connection, use an Ethernet crossover cable). Ethernet –or–...
  • Page 7: Power-On

    Power Jack Transformer 01-17010 The ReachDSL modem hardware installation is now complete. When the power cord is installed, the ReachDSL modem goes through a power-on self-test. Power-On When power is applied, the ReachDSL modem performs self-diagnostics and the PWR LED is on. The self-diagnostics includes a power-on self-test and all of the LEDs turn on for one second.
  • Page 8: Status Leds

    The DSL link has not been established. Data transmission is in progress on the DSL line. The modem is not transmitting or receiving data. The Ethernet connection to the Ethernet hub or PC is active. No Ethernet 10BaseT device is detected.
  • Page 9: Troubleshooting

    Troubleshooting LED Symptom Action All LEDs are on. If LEDs remain on after ten minutes, the modem is not functional. Contact the service provider. ALM LED remains The power-on self-test may have failed. Unplug the unit and reapply power. If the alarm LED is still on, contact the service provider.
  • Page 10: Increasing The Number Of End-User Systems

    To improve data transmission throughput and minimize background noise during a telephone conversation, make sure that: The Hotwire 6350 ReachDSL Modem is always powered on, even when not in use, A Hotwire phone filter is installed on every telephone on the same line as the...
  • Page 11: Cables & Connectors

    Cables & Connectors This section is reference information. Standard twisted-pair CAT3 or better cables are recommended. The LINE and PHONE interface connectors use 6-pin, non-keyed modular plugs. RJ11 or RJ14 6-pin connectors can be used. Line & Phone Connectors Pin # Function Not used Ring 2 (optional) DSL Ring 1...
  • Page 12 4 & 5 Not used 10BaseT RX D– 7 & 8 Not used –or– — To connect the DSL modem directly to a PC with an Ethernet NIC card, use an Ethernet crossover cable. 8-Pin Ethernet Crossover Cable Function 10/100BaseT TX D+ 10/100BaseT TX D–...
  • Page 13: Optional Reachdsl Modem Wall Placement

    Optional ReachDSL Modem Wall Placement The Hotwire 6350 ReachDSL Modem is designed for tabletop placement. The modem can also be mounted on a wall. To mount the modem, you will need: Two slotted-head #6 self-threading screws with plastic anchors Drill and 3/16" drill bit for the plastic anchors Screwdriver A template with the dimensions for the two screws is provided.
  • Page 14: Reachdsl Modem Hardware Template

    ReachDSL Modem Hardware Template 01-17014...
  • Page 15: Technical Specifications For Hotwire 6350 Reachdsl Modem

    Technical Specifications for Hotwire 6350 ReachDSL Modem Item Height x Width x Depth Weight Power Class 2 Transformer normal service input voltage range Approvals FCC Part 15 CISPR 22 Other Certifications Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration...
  • Page 16: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
  • Page 17 CE Marking When the product is marked with the CE mark on the equipment label, this demonstrates full compliance with the following European Directives: Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68/EEC.
  • Page 18: Declaration Of Conformity

    Declaration of Conformity This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2 and 15 of the Federal Communications Commission’s Rules. This compliance information statement pertains to the following products: Trade Name: Hotwire Model Number: 6350-A4-200 This device complies with Part 15 of the FCC Rules. Operation is subject to the following...
  • Page 19: Supplier's Declaration Of Conformity

    Largo, FL 33773-1502 Date of Issue: 8/17/2001 Paradyne Corporation, located at the above address, hereby certifies that the Hotwire ReachDSL™ Model Number 6350-A4-200, bearing labeling identification number US:AW2DL03B6350-A4 complies with: the Federal Communications Commission’s (“FCC”) Rules and Regulations 47 CFR Part 68, the Administrative Council on Terminal Attachments (“ACTA”)-adopted technical criteria TIA/EIA/IS-968, “Telecommunications –...
  • Page 20: Government Requirements

    — Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. — Telephone: Call our automated system to receive current information via fax or to speak with a company representative.
  • Page 21: Notice To Users Of The Canadian Telephone Network

    8. This equipment cannot be used on public coin service provided by the telephone company. Connection to Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.) 9. An FCC compliant telephone cord with modular plugs may be provided with this equipment.
  • Page 22: Warranty, Sales, Service, And Training Information

    Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.
  • Page 24   "   *6350-A2-GN12-00*...

This manual is also suitable for:

6350

Table of Contents