CHARGING SYSTEM
–
Generator
REMOVAL OF GENERATOR (3VZ–E)
1. DISCONNECT CABLE FROM NEGATIVE TERMINAL OF
BATTERY
2. DISCONNECT WIRING FROM GENERATOR
(a) Disconnect the connector from the generator.
(b) Remove the nut and disconnect the wire from the
generator.
3. REMOVE GENERATOR DRIVE BELT
Loosen the generator pivot bolts, adjusting nut and lock
bolt and remove the generator drive belt.
4. REMOVE GENERATOR
(a) Remove the pivot bolt and adjusting lock bolts.
(b) Remove the generator.
CH–7