3.
Put timer during Z-axis operation.
If the tip load attached to the spline tip of the YK250XGC(P), YK350XGC(P), YK400XGC(P), YK500XGLC(P), or
YK600XGLC(P) exceeds 2kg, the Z-axis may be overloaded depending on the operation pattern.
In this case, put a timer during operation as shown in the Fig. below to prevent overload of the Z-axis. The reference
timer values are shown below. Furthermore, the maximum payload is 4kg. If the tip load exceeds this maximum payload,
the Z-axis may be overloaded easily. So, do not operate the robot with a tip load exceeding 4kg.
Putting timer during Z-axis operation
4.
Z-axis additional mechanical stopper
The Z-axis additional mechanical stopper cannot be installed in the YK250XGC(P), YK350XGC(P), YK400XGC(P),
YK500XGLC(P), and YK600XGLC(P) as they are equipped with bellows.
5.
Detach or attach the Y-axis arm cover.
The Y-axis arm cover cannot be detached or attached unless the Z-axis is moved down to its lower end. For details, see
"9. Detaching or attaching the covers" in Chapter 2.
ii
Upper end
Lower end
Total timer, 1.0 sec.
Only Z-axis operates
Timer, 0.5 sec.
Timer, 0.5 sec.
All axes operate
23002-HM-00