7.5

Mounting

Mounting instructions
These motors are electrically operated. When electrical equipment is operated, certain
parts of these motors are at hazardous voltage levels. If this motor is not correctly
handled/operated, this can result in death or severe bodily injury as well as significant
material damage. Please carefully observe the warning information in this section an on the
product itself.
Only qualified personnel may carry-out service or repair work on this motor.
Before starting any work, the motor must be disconnected from the line supply and
grounded.
Only spare parts, certified by the manufacturer, may be used.
The specified service/maintenance intervals and measures as well as the procedures for
repair and replacement must be carefully maintained and observed.
When transporting the motors, use all of the hoisting lugs provided!
All work should be undertaken with the system in a no-voltage condition!
The motor should be connected up according to the circuit diagram provided.
In the terminal box it must be ensure that the connecting cables are insulated with respect
to the terminal board cover.
After the motor has been installed, the brake (if one is used) must be checked to ensure
that it is functioning perfectly!
Note
Flange mounting is only possible using studs and nuts. Clearance M1 for threading the nut
between the motor flange and motor frame acc. to DIN 42677 (see table).
Table 7- 2
1PH4 Induction Motors
Configuration Manual, (APH4S), 08/2008, 6SN1197-0AD64-0BP1
WARNING
WARNING
Flange mounting with threaded studs and nuts
Shaft height [mm]
100
132
160
Information on the application of motors
M1 [mm]
44
50
65