To separate the batteries from the housing case:
To remove the rechargeable battery, you need a flat-head (standard) screwdriver. Observe basic safety precautions when you follow the procedure
outlined below. Be sure to protect your eyes, hands, fingers and the surface on which you work.
1
4235 006 36461-671_ 13-03-22
(YY_MM_DD)
1.
To deplete the rechargeable battery of any charge,
remove the handle from the charger, turn on the
Sonicare and let it run until it stops. Repeat this step
until you can no longer switch on the Sonicare.
2.
Insert a flathead (standard) screwdriver into the slot
located at the bottom of the handle. Turn the
screwdriver counterclockwise to release the bottom cap
3.
Place the handle on a solid surface with the buttons
facing up and lightly tap the housing one inch from the
bottom edge with a hammer.
4.
Hold the handle upside down and push down on the
shaft to release the internal components of the handle.
5.
Insert the screwdriver under the circuit board, next to
the battery connections, and twist to break the
connections. Remove the circuit board and pry the
battery from the plastic carrier.