Manufacturer's Declaration of Conformity
This product has been manufactured in accordance with the
harmonized European standards, following the provisions of the
below stated directives:
93/42/EEC
2007/47/EC
Medical Device Directive
2014/31/EU
Non-automatic Weighing Instruments
Directive
Please see separate document showing on sticker of device for
above CE marking.
Authorized EU Representative:
Manufactured by:
Charder Electronic Co., Ltd.
No.103, Guozhong Rd., Dali Dist.,
Taichung City 412, Taiwan (R.O.C.)
FDA no.: D072479
IN-1224 [12185F] 04/2016
as
amended
- 43 -
by
Please keep the instruction manual at hand all the time for future reference.
MS 6000
BED SCALE

USER MANUAL

- 0 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS 6000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Charder MS 6000

  • Page 1: User Manual

    Directive Please see separate document showing on sticker of device for above CE marking. Authorized EU Representative: Manufactured by: Charder Electronic Co., Ltd. MS 6000 No.103, Guozhong Rd., Dali Dist., BED SCALE Taichung City 412, Taiwan (R.O.C.) FDA no.: D072479 USER MANUAL Please keep the instruction manual at hand all the time for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS NOTE PREFACE ....................2 GENERAL INFORMATION ..............2 SAFETY INSTRUCTION ................ 2 ENVIROMENTAL ................... 3 CLEANING....................3 MAINTENANCE ..................3 WEIGHING OPERATION ............... 4 WARRANTY-LIABILITY................ 4 DISPOSING OF THE SCALE ..............5 EXPLANATION OF THE GRAPHIC SYMBOLS........6 TEMPERATURE &...
  • Page 3: Preface

    PREFACE NOTE Thank you for choosing CHARDER MEDICAL product. All features of this product were designed to state of the art and are optimized for simple and straightforward use. If you have any queries or experience any problems not addressed in the operating...
  • Page 4: Enviromental

    2. LCD display faulty If you have any problem, contact your local CHARDER MEDICAL service Possible hardware defects include: Uneven brightness in the LCD partner. display screen & texts color blurred, smeared rainbow screen, incorrect decimal display ENVIROMENTAL LCD PIN broken or short circuit PCB cooper foil broken &...
  • Page 5: Weighing Operation

    3. Connection failure for data transmission to PC or printer unit. Replaced parts shall be the property of CHARDER. Should the Wrong connection wires or faulty wires for transmission between fault repairs or replacement delivery not be successful, the statutory the digital indicator &...
  • Page 6: Disposing Of The Scale

    TROUBLESHOOTING functioning shall be rendered null and void. If CHARDER provides and individual warranty, this means that the unit supplied will be Troubleshooting for defective modes: free of faults for the length of the warranty period. Original purchaser can enjoy the benefits under the effective Warranty...
  • Page 7: Explanation Of The Graphic Symbols

    “Please note the accompanying documents“ or “Observe operating instructions” Identification of manufacturer of medical product including address Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.) “Electro-medical appliance“ with attachment for type B Dispose of old appliances...
  • Page 8: Temperature & Humidity

    Carefully read this operation manual before setup and commissioning, even if you are already familiar with Charder scales. Transport and storage temperature +60°C limit indicating the upper and the lower limit Place the housing back (Transport and storage temperature -20°C...
  • Page 9: Emc Guidance And Manufacturer's Declaration

    EMC guidance and manufacturer's declaration Guidance and manufacturer’s declaration-electromagnetic Rechargeable emissions Battery Housing The MEDICAL SCALE MS6000 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS6000 should assure that it is used in such an environment. Electromagnetic Emission test Compliance...
  • Page 10 Guidance and manufacturer’s declaration-electromagnetic immunity INSTRUCTION FOR REPLACING BATTERIES The MEDICAL SCALE MS6000 is intended for use in the electromagnetic environment specified below. The customer or the user of the MEDICAL SCALE MS6000 should assure that it is used in such an environment. IEC 60601 test Compliance Electromagnetic...
  • Page 11 3 A/m 3 A/m Power The MEDICAL SCALE INSTRUCTION FOR CHARGING AND CONNECTING frequency(50/60 MS6000 power Hz) magnetic frequency magnetic field IEC 61000- fields should be at levels prompt displays on the LCD, please change the characteristic of a typical location in a scale batteries or use exclusive adaptor to operate the scale.
  • Page 12 RS232 Pin out Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol: Connecting with PC 1.
  • Page 13 PRINTING FUNCTION Recommended separation distance between portable and mobile RF communications equipment and the MEDICAL SCALE Weight, BMI and Height results can be printed for records using The MEDICAL SCALE MS6000 is intended for use in an electromagnetic RS232 interface cable (included in accessory kit). environment in which radiated RF disturbances are controlled.
  • Page 14: Specification

    SPECIFICATION SET UP YOUR DEVICE Switch ON the scale and long press [ZERO] key for 3 seconds, first Model MS 6000 “SETUP” and then “A.OFF” will display successively. Capacity 500kg x 200g AUTO-OFF TIME SETUP This enables operator to select the auto turn OFF time of the device.
  • Page 15: Medical Scale Models Approval List

    MEDICAL SCALE MODELS APPROVAL LIST The Medical Scales MS6000 listed below are the certified Press numeral key 0 ~ 9 to models under the Council Directive for standard of assign the position to pre-tare 2007/47/EC weight. safety, health protection and accurate metrology characteristics of medical scales: PRODUCT PRODUCT MODEL NO.
  • Page 16: Power Adaptor Standards

    POWER ADAPTOR STANDARDS DRAWING NO.: CE APPROVED TYPE NO. TYPE Press ENTER key to store pre- VOLTAGE / MODEL NO.: tare weight; the instrument will make double beep sound. 9V DC 100mA AD-038A REV 007 D41W1090100-13/1 9V DC 100mA AD-0484 REV 001 D35W090100-23/1 9V DC 100mA AD-0484 REV 001...
  • Page 17: Preparation For Measurement

    [PRE-TARE] key. STORING AND RE-CALLING PRE-TARE WEIGHT Charder Bed Scale can store 10 sets of pre-tare values, and there are two methods to store pre-tare value – Using Dead Weight or Enter weight using 0~9 keys: A.
  • Page 18 Push bed forward and move to the weigh bridges after USING BMI FEATURE assembly and power on the scale. Follow the normal weighing procedure. Long press BMI key for 3 seconds, after the weight stabilizes and the stable sign displays on the LCD, the middle LCD will display previous height value.
  • Page 19: Installing Weigh Bridge

    USING HOLD FUNCTION Charder Bed Scale has been properly labeled for easy assembling. Charder Bed Scale is provided with the integrated hold function to determine the average weight. It enables people to be weighed The packing also includes Weigh Bridge, connecting wire and accurately although they are not still on the bed.
  • Page 20: Panel

    Use 0~9 keys to set the increase PANEL in weight limit and press ENTER. Now the lower display will start blinking and point to (-) weight limit. (**), press 0~9 keys to set the decrease in weight limit, the minus (-) sign will appear in front of the weight decrease value, after setting the values press ENTER.
  • Page 21: Lcd Symbol Description

    To print out the weighing result, MONITOR For tracking the change in weight of Patient. press PRINT key. WEIGHT To turn ON/OFF and adjust volume level of ALARM Alarm function CLEAR To clear the wrong entry while entering digits. WEIGHT TRACKING PROCEDURE Prepare the bed;...
  • Page 22: Date & Time Setting Procedure

    DATE & TIME SETTING PROCEDURE NORMAL WEIGHING PROCEDURE(patient on the bed) Turn On the scale using ON/OFF key. Switch ON the scale using ON/OFF key and then long press **(before moving bed on the weigh bridge) key for 3 seconds to enter the TIME SETTING mode. Press Call the PRE-TARE value (bed key after successful change to move to next step.