HP 83522A Service Notes page 41

Rf plug-.in including options 002 and 004
Table of Contents

Advertisement

Operation
Model 83522A
Figure 3-8. Configuration Switch
NOTES
1.
Switch Positions
3.
When direct-coupled FM is selected,
1
=
Switch Open
=
High
FM sensitivity is -20 mHz/V and
0
=
Switch Closed
=
Low (Ground)
switch Number 5 is overridden.
x
=
Don't Care
*
=
Varies; 1
if Opt. 002, 0 if no Opt. 002
2.
Switch is set at the factory as follows:
4.
Switches with
t
should not be changed
from Factory setting.
Switch Number
Description
1
2
3
4
5
6
7
8
I
,
t ~ o d e for 83522APlug-in (Note 4)
0
0
0
X
X
X
X
X
RF
Power Off at Instrument Preset
X
X
X
1
X
X
X
X
Maximum RF Power at
X
X
X
O
X
X
X
X
Instrument Preset
-6 MHz/V FM Sensitivity
-20 MHz/V FM Sensitivity
Direct-Coupled FM (Note 3)
Crossover- Coupled FM
%tep Attenuator Option 002
Installed (Note 4)
?No Step Attenuator (Note 4)
X
X
X
X
l
X
X
X
X
X
X
X
O
X
'
X
X
X
X
X
X
X
l
X
X
X
X
X
X
X
O
X
X
X
X
X
X
X
X
l
X
X
X
X
X
X
X
O
X