Making Measurements

Selecting the ATM Measurement Parameters

Selecting the ATM Measurement Parameters
Description
You need to make a number of selections which define the type of test you
want to make and the cell which you want to be subject of the test.
TIP:
If you wish to set the HP 37717C transmitter and Receiver to the same
interface settings, choose
will couple common selections, for example, interface and cell payload
but will NOT couple the cell header.
HOW TO:
1 Select the signaling INTERFACE: User Network Interface
network, or Network Node Interface
switches in the public network.
2 Select how the cell stream to be tested is defined by setting CELL
SELECTED FOR TEST.
To specify by header VPI, select
To specify by header VPI and VCI, select
To specify by all of the header, select
In addition to these choices you can select
For OAM analysis, select
Selection of
104
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
OTHER
Typically used between a user and a switch in the public
UNI
or
UNASSIGNED CELLS
or
SEGMENT
SETTINGS CONTROL COUPLED
typically used between
NNI
.
VP
.
VC
EXPERT MODE
ALL USER CELLS
.
IDLE CELLS
for the VP OAM or
VP
PERFORMANCE
END TO END
. This
for the VC OAM
VC