configure any other feature on the VLAN, neither the configured feature nor the BFD MAD function
can work correctly.
Do not enable the spanning tree feature on any port in the BFD MAD VLAN. The MAD function is
•
mutually exclusive with the spanning tree feature.
Do not bind a BFD MAD-enabled VLAN interface to any VPN. The MAD function is mutually
•
exclusive with VPN.
To avoid anomalies, make sure a BFD MAD-enabled VLAN interface has only IP addresses
•
assigned with the mad ip address command. Do not use any other command, including the ip
address command, to assign an IP address to the interface.
•
All MAD IP addresses on the BFD MAD-enabled VLAN interface must be on the same subnet.
If an intermediate device is used, assign the ports of the BFD MAD links to the BFD MAD VLAN on
•
the device.
Step
1.
Enter system view.
2.
Assign a domain ID to the
IRF fabric.
3.
Create a VLAN dedicated to
BFD MAD.
4.
Return to system view.
5.
Enter interface view or
interface range view.
6.
Assign the port or the range
of ports to the BFD MAD
VLAN.
7.
Return to system view.
8.
Enter VLAN interface view.
Command
system-view
irf domain domain-id
vlan vlan-id
quit
•
Enter interface range view:
Approach 1:
interface range { interface-type
interface-number [ to
interface-type
interface-number ] } &<1-5>
Approach 2:
interface range name name
[ interface { interface-type
interface-number [ to
interface-type
interface-number ] } &<1-5> ]
•
Enter interface view:
interface interface-type
interface-number
•
Assign the port to the VLAN as an
access port:
port access vlan vlan-id
•
Assign the port to the VLAN as a
trunk port:
port trunk permit vlan vlan-id
•
Assign the port to the VLAN as a
hybrid port:
port hybrid vlan vlan-id { tagged |
untagged }
quit
interface vlan-interface
vlan-interface-id
26
Remarks
N/A
By default, the domain ID of an
IRF fabric is 0.
The default VLAN on the device
is VLAN 1.
N/A
To assign a range of ports to the
BFD MAD VLAN, enter interface
range view.
To assign one port to the BFD
MAD VLAN, enter Ethernet
interface view.
Choose one command
depending on the port type.
BFD MAD has no requirement for
the link type of the detection
port.
The default link type of a port is
access.
N/A
N/A