Input Power; Clearance And Location - Toshiba Strata DK40 Installation & Maintenance Manual

Hide thumbs Also See for Strata DK40:
Table of Contents

Advertisement

DK40 Installation

Input Power

The system requires an input power source of 220~240 VAC, 50/60 Hz, 13 amps. The AC
outlet is recommended to be dedicated and unswitched, with a solid third-wire earth.
"AC Power and Earthing Requirements" on Page 2-4 for more
This eliminates interference from branch circuit motor noise or the like, and to prevent
accidental power-off. To avoid accidental power turn-off, Toshiba recommends that you do
not use an ON/OFF wall switch on this dedicated AC circuit.
For the Strata DK40, a reserve power source (two customer-supplied 12-volt batteries) may
be connected to the system to serve as a power failure backup.

Clearance and Location

The minimum clearance requirements for the Strata DK40 Base and Expansion KSUs are
shown in
Top View
Front View
311mm
DK40
Base KSU
2158
Figure 2-1
DK40 Base KSU Clearance
Requirements
Consider the following conditions when selecting a location for the KSU(s):
The location must be:
Dry and clean
Well ventilated
Well illuminated
Easily accessible
2-2
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Figures 2-1
and 2-2. Refer to
88.5mm
Wall
50.5mm
457.0mm
50.5mm
Page 2-1
for DK40 KSU mounting instructions.
Top View
Expansion
Front View
507.5mm
Expansion
Unit
1625
Figure 2-2
DK40 Base KSU and
Expansion KSU Clearance
Requirements
Strata DK40 I&M Manual Spring 1999
Site Requirements
information..)
Base
88.5mm
Wall
50.5mm
DK40
457.0mm
Base KSU
50.5mm
(See

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents