PREFACE
This Surveillance Unit is intended for installation on the WA-
MA120N/240N Mixing Power Amplifier (sold separately).
Installation of the Surveillance Unit ensures system reliability
and safety by detection of speaker line failures, as well as
audio signal problems and abnormally high temperatures in
the amplifier.
• Detects and notifies speaker line faults (shorts,
disconnections, grounding), amplifier audio signal
problems, and abnormally high amplifier temperatures.
• A built-in interval timer schedules automatic checks for
speaker line failures at a preset interval.
• Non-stop monitoring for amplifier audio signal problems and
FEATURES
Speaker Line Check
• Speaker lines can be checked individually for shorts and
disconnections.
• Overall speaker line check for grounding.
• Speaker line check is performed according to the time
interval setting.
Notification about any faults occurred during the time interval
will not be made at once. See the illustration below for
details.
Next fault detection and notification
Check
Check
Time
Fault
(n)
(n-1)
Time interval
• Check interval can be set to none, 10 minutes, 60 minutes,
or 24 hours. The factory default setting is 24 hours.
• Execution of speaker line failure detection cancelled during
all-zone announcement.
And it will not be resumed automatically when all-zone
announcement ends.
• Indicators on the front panel of the mixing power amplifier
signal malfunction. Notification of the fault is also sent from
the SURVEILLANCE I/F connector at the same time.
Detection of a short in a speaker line causes automatic cut
off of the line's output.
• CHECK/SETTING switch can be used to execute the
speaker line check or to set the line impedance reference
62
abnormally high temperatures, and notifies when
abnormalities are discovered.
• Speaker line failure detection can be executed by Sound
Message Unit scheduler.
• Switch operation allows manual execution of speaker line
check.
• SURVEILLANCE I/F connector supports execution of
speaker line check and acquisition of each fault notification.
• Fault notification from the SURVEILLANCE I/F connector
allows configuration of a system that switches to a backup
amplifier when the power amplifier has a problem.
value. The same setting is also possible from the
SURVEILLANCE I/F connector.
• The Surveillance Unit's indicator and the FAULT indicator on
the front of the mixing power amplifier flash to indicate that
speaker line failure detection is in progress and while the line
impedance reference value is being obtained.
• Detection of a short causes the applicable line to be cut.
• The speaker line check will not be performed during all-zone
announcement.
And when there is no all-zone announcement, it will be
performed as scheduled by the time interval setting.
Detection of Amplifier Audio Signal Problems
• Audio output of the amplifier is constantly monitored to
ensure operation is normal.
• Indicators on the front panel of the mixing power amplifier
signal problems. Notification of the problem is also sent from
the SURVEILLANCE I/F connector at the same time.
Detection of Abnormally High Amplifier Temperature
• The amplifier is constantly monitored to ensure normal
temperature increase.
• Indicators on the front panel of the mixing power amplifier
signal abnormalities. Notification of the abnormality is also
sent from the SURVEILLANCE I/F connector at the same
time.
MAJOR OPERATING CONTROLS & TERMINALS
Top of Unit
1 CN101 Terminal
2 CN102 Terminal
3 CN103 Terminal
4 CN104 Terminal
5 DIP Switches
DIP Switch
Name
Number
1
Fixed settings
2
TIMER1
3
TIMER2
4
MASTER/SLAVE
5
POWER ON CHECK
6
BUS SYNC ENABLE
6 SURVEILLANCE I/F Connector
Pin Number
Signal Name
1
ZONE1 SHORT
2
ZONE1 OPEN
3
ZONE2 SHORT
4
ZONE2 OPEN
5
ZONE3 SHORT
6
ZONE3 OPEN
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
GROUND FAULT
12
PA SIGNAL FAULT
13
CHECKING/SETTING
BUSY
14
REFERENCE ERROR
15
GND
16
PA TEMP FAULT
17
COMM FAULT
18
Reserved
19
Reserved
20
Reserved
21
GND
22
CLOCK ADJ CONT
23
SP LINE REFERENCE
SETTING ACTIVATION
24
SP LINE CHECK
ACTIVATION
25
GND
PRODUCTS
WU-ZS001E
Description
Settings
Factory
Default
Fixed at factory default setting
ON
Interval timer setting 1
None/10 minutes/ 24 hours
Interval timer setting 2
60minutes/24 hours
Master/slave setting
MASTER/SLAVE MASTER
Power on speaker line check setting ON/OFF
ON
Speaker line test sync on/off for ON/OFF
OFF
multi-amp connection
IN/OUT Signal/Logic
Required Action
OUT
Active Low Zone 1 speaker line is shorted.
OUT
Active Low Zone 1 speaker line is disconnected.
OUT
Active Low Zone 2 speaker line is shorted.
OUT
Active Low Zone 2 speaker line is disconnected.
OUT
Active Low Zone 3 speaker line is shorted.
OUT
Active Low Zone 3 speaker line is disconnected.
OUT
Active Low Some speaker lines are grounded.
OUT
Active Low Power amplifier audio signal is faulty.
OUT
Active Low During measurement of the speaker line reference
impedance or during check of the speaker lines.
OUT
Active Low The speaker line reference impedance couldn't
be measured successfully.
GND
GND
OUT
Active Low Power amplifier temperature is faulty.
OUT
Active Low Serial Communication is faulty.
GND
IN
One-shot make Adjust control of Interval clock
IN
One-shot make Measurement of the speaker line reference
impedance (Initial setting) starts.
IN
One-shot make Check of the speaker line impedance starts.
GND