2-2. Voltage adjustment channel setup

1. Press the V key.
2. Turn a rotary encoder and set the adjusting channel.
3. Press the MEMORY key.
4. Select the OUTPUT SELECT of the channel to adjust.
2-3.
Connection of constant apparatus
Connect the output CH to adjust PWA, and COM terminal to DMM.
2-4.

Voltage rating 100% adjustment

1. Set up a voltage display in DIGIT key and a rotary encoder. (refer to the following list)
2. Turn on MAIN OUTPUT
3. Adjust in DIGIT key and a rotary encoder so that it becomes within the limits of the following list of the value of
DMM.
4. Press the MEMORY key.
MODEL NAME
PW18-1.8AQ
PW18-1.3AT
PW18-3AD
PW36-1.5AD
PW18-3ADP
PW18-2ATP
PW16-5ADP
PW8-3ATP
PW26-1AT
PW36-1.5ADP
ADJUSTMENT
SETTING VOLTAGE
CH1
18.00 V
CH2
-18.00 V
CH3
8.000 V
CH4
-6.000 V
CH1
18.00 V
CH2
-18.00 V
CH3
6.000 V
CH1
18.00 V
CH2
-18.00 V
CH1
36.00 V
CH2
-36.00 V
CH1
18.00 V
CH2
18.00 V
CH1
36.00 V
CH2
18.00 V
CH3
8.000 V
CH1
6.000 V
CH2
16.00 V
CH1
8.000 V
CH2
8.000 V
CH3
18.00 V
CH1
26.00 V
CH2
-26.00 V
CH3
6.00 V
CH1
36.00 V
CH2
36.00 V
ADJUSTMENT RANGE
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
± 1 mV
PW-A