P144 I/O Bit Links (Jumpers) - Emerson FloBoss S600 Instruction Manual

Panel-mount flow computer designed specifically to measuring hydrocarbon liquid
Hide thumbs Also See for FloBoss S600:
Table of Contents

Advertisement

S600 Instruction Manual

4.1.10 P144 I/O Bit Links (Jumpers)

4-14
Table 4-12. PRT/PRD Input Pin Connections for SKT-B
Pin
4
1
21
24
5
2
22
25
6
3
23
26
The boldface entries in the Position column on Table 4-13 are the
default configuration settings. These may not apply to your specific
configuration. Do not change the bit link settings unless told to do so
by the factory.
: Point to point communications for the P144 I/O board require
Note
Link 2 to be ON. Multiplex (MUX) communications require Link 2 to
be OFF.
Function
PRT-CH1 I+
PRT-CH1 V+
PRT-CH1 V-
PRT-CH1 I-
PRT-CH2 I+
PRT-CH2 V+
PRT-CH2 V-
PRT-CH2 I-
PRT-CH3 I+
PRT-CH3 V+
PRT-CH3 V-
PRT-CH3 I-
I/O
Revised Jan-07