Section 3: HP 5242-ACL Tape Drive
FRU 1 Dead
Error
FRU 2 Dead
Error
FW Check
Status
FW Data
Error
Flashing The autoloader has failed
Err
FW
Status
Upgrade
FW Read
Error
Flashing A firmware upgrade failed
Fail
FW Tape
Error
Flashing A firmware upgrade failed
Write
Protected
FW Write
Error
Flashing A firmware upgrade failed
Fail
Illegal FW
Error
Flashing The autoloader has failed
Illegal HW
Error
Flashing The autoloader has failed
Insert Mag
Status
Load Tape
Info
Loading
Status
HP StorageWorks DAT 72 (Models 5242 and 5242-ACL) User's Guide
On
The controller board for the
embedded drive has failed
its self-test.
On
The drive mechanism has
failed its self-test.
Firmware upgrade data is
being checked for
compatibility.
to upgrade the drive
firmware because the new
firmware is corrupt.
Firmware upgrade data is
being read either through a
tape or the SCSI bus.
because of an error in
reading data from the tape.
because the tape is write-
protected.
because of an error in
writing a modified upgrade
count to the tape.
to upgrade the drive
firmware because the new
firmware is incompatible.
to upgrade the drive
firmware because the new
firmware is for
incompatible hardware.
The autoloader is waiting
for you to insert a
magazine.
Displayed when you press
the Load Tape button.
Either a cartridge is being
moved from the magazine
and placed into the drive
mechanism, or the drive is
loading a cartridge.
Call the HP GCSC.
Call the HP GCSC.
Obtain a good copy of
the firmware upgrade.
Try again. If it still
fails, call the HP
GCSC.
Change the write-
protect switch on the
tape and try again.
Try again. If it still
fails, call the HP
GCSC.
Obtain a correct
version of the firmware
upgrade.
Obtain a correct
version of the firmware
upgrade.
43