5

10.5 SPECIFICATION ABOUT THE THERMAL PROTECTION

∗ The change of HI / LO have hysterisis curve below.
Reading Value of the Sensor and FAN Drive
T4
(Outside air
55 ºC)
T3
(Outside air
40 ºC)
T2
(Outside air
37 ºC)
T1
(Outside air
33 ºC)
T0
(Outside air
30 ºC)
FAN: STOP
FAN: LO
Assign
T4 setting
T3 setting
Pin 76
TEMP2
T2 setting
T1 setting
T0 setting
Assign
Pin 149 (FAN_CONT)
Pin 17 (FAN_CONT_POW)
Unit State and Fan Drive
POWER PSW1
State
ON
ON
ON
ON
ON
DT_REC
OFF
STB
[System block diagram]
MAIN UCOM
149
Operation when executing FAN control command
When executing [FCNS00], [FCNS01], [FCNS02] command, detect the FAN_NG signal. When NG is detected, it becomes shutdown.
When [FCNS03] command is executed, FAN_NG detection is not operated.
5
6
FAN: HIGH
FAN: LO
AD Value
Aims
10 bit
(Sensor Position)
440
55 ºC
568
40 ºC
592
37 ºC
627
33 ºC
653
30 ºC
FAN: HIGH
FAN: LO
H
H
H
L
Control
According to the reading value of above table sensor.
According to the reading value of above table sensor.
FAN_CONT: "L"
Vref=2.64V
H: Vo = 9.5 V
L: Vo = 7 V
17
PDP-427XD
6
7
FAN: STOP
Aims
(Outside Air)
55 ºC
40 ºC
37 ºC
33 ºC
30 ºC
STOP
L
FAN Operation
HIGH or LO
HIGH or LO
OFF
Vo
FAN_Vcc
REG
H: On
L: Off
7
8
FAN: LO
FAN: HIGH
SD
8
A
B
C
D
E
F
167