Projector Status - Panasonic DLP PT-D6000 Functional Instructions

Dlp based projector for commercial use
Hide thumbs Also See for DLP PT-D6000:
Table of Contents

Advertisement

STATUS

Projector status

Click the Projector status tab on the top.
PROJECTOR TYPE
Displays the type of projector.
Displays the firmware version of the
MAIN VERSION
projector main unit.
INPUT
Displays the input switching status.
INPUT AIR
Displays temperature of projector's
TEMPERATURE
intake air.
OPTICS MODULE
Displays temperature inside the
TEMPERATURE
projector.
AROUND LAMP
Displays temperature around lamp
TEMPERATURE
units.
LAMP1 RUNTIME/LAMP2
Displays the lamp lit hours.
RUNTIME
PROJECTOR RUNTIME
Displays used hours of the projector.
SELF TEST
Displays self diagnosis information.
Error information
When
is displayed in
Error (Detail)
status list, click
to display the error details.
(Detail)
in the
SELF TEST
Click (Detail)
Technical Information
Parameter
Trouble has occurred in the
MAIN CPU BUS
microcomputer circuitry. Consult your
dealer.
Trouble has occurred in the fan or its
FAN
drive circuit. Consult your dealer.
The input air temperature is too high. It
may be that the projector is being used
INPUT AIR
in an operating environment where the
TEMPERATURE
temperature is high such as near a
heating appliance.
The temperature inside the projector is
high. It may be that the projector is
OPTICS MODULE
being used in an operating
TEMPERATURE
environment where the temperature is
high such as near a heating appliance.
The temperature around the lamp is
AROUND LAMP
too high. It may be that the projector's
TEMPERATURE
ventilation holes are blocked.
LAMP1 REMAIN TIME
The lamp runtime has exceeded the
prescribed cumulative time, and it is
LAMP2 REMAIN TIME
now time to replace the lamp.
LAMP1 STATUS
The lamp has failed to light. Wait a
short while for the lamp to cool off, and
LAMP2 STATUS
then turn on the power.
Trouble has occurred in the shutter
SHUTTER
circuitry. Consult your dealer.
Trouble has occurred in the sensor
INPUT AIR TEMP.SENSOR
used to detect the input air
temperature. Consult your dealer
Trouble has occurred in the
OPTICS MODULE
temperature detection sensor inside
TEMP.SENSOR
the projector. Consult your dealer.
Trouble has occurred in the sensor
AROUND LAMP
used to detect the exhaust air
TEMP.SENSOR
temperature. Consult your dealer.
The backup battery has been run out.
BATTERY
Consult your dealer.
Trouble has occurred in the sensor
AIRFLOW SENSOR
used to detect the airflow volume.
Consult your dealer.
Trouble has occured in the colour
COLOR WHEEL
wheel or colour wheel or its drive
circuit. Consult your dealer.
The lamp unit cover is not attached
COVER OPEN
securely. Check the lamp unit
compartment.
The air cleaning filter (ACF) is not
installed or trouble has occurred. See
ACF UNIT
the operating instructions booklet that
is provided with the projector.
The filter remaining is getting less. See
FILTER REMAIN
the operating instructions booklet that
is provided with the projector.
Description
E
NGLISH - 43