RUGGEDCOM RS930L
Installation Guide

Communication Ports

The RS930L can be equipped with various types of communication ports to enhance its abilities and
performance. To determine which ports are equipped on the device, refer to the factory data file available through
ROS . For more information on how to access the factory data file, refer to the ROS User Guide for the RS930L.
Each communication port type has a specific place in the RS930L chassis.
Figure 8: Port Assignment
1. Ports 1 to 6
2. Port 7
Port
1 to 6
7
9
The following sections describe the available ports:
Section 3.1, "EoVDSL Ports"
Section 3.1

EoVDSL Ports

Ethernet over VDSL (EoVDSL) ports operate in pairs with one device configured as the Master and the other as
the Slave. In VDSL (Very-high-bit-rate Digital Subscriber Line), the terms Central Office (CO) or Line Termination
(LT) are used interchangeably for the Master and the terms Customer Premise Equipment (CPE) or Network
Termination (NT) are used interchangeably for the Slave. The Master device dictates the line configuration
settings to the Slave so all EoVDSL configuration is done on the Master. Data flowing from the Master to the
Slave is designated downstream while data flowing from the Slave to the Master is designated upstream.
EoVDSL Ports
2
1
3. Port 9
Type
Fast Ethernet Ports (10/100Base-TX)
EoVDSL Port
EoVDSL Port
3
Chapter 3
Communication Ports
13