Device management
This chapter includes these sections:
Configuring the device name
•
Configuring the system clock
•
Enabling displaying the copyright statement
•
•
Configuring banners
Configuring the exception handling method
•
Rebooting the device
•
Configuring scheduled tasks
•
Configuring the detection timer
•
•
Configuring temperature alarm thresholds for a member device
When the temperature of the device reaches a threshold, the device generates alarms.
•
The temperature alarm thresholds include the low-temperature threshold, high-temperature warning
•
threshold, and high-temperature alarming threshold.
If the temperature is lower than the low-temperature limit, the device logs the event and outputs the log
information and trap information for users.
If the temperature reaches the high-temperature warning threshold, the device logs the event and
•
outputs the log information and trap information for users.
If the temperature reaches the high-temperature alarming threshold, the device not only repeatedly
•
outputs the log information and trap information in the terminal display, but also alerts users
through the LED on the device panel.
While you are cooling down the device in response to a high-temperature
•
of the device might fluctuate in a narrow range near a high-temperature threshold. The device can
suppress frequent alarms caused by some fluctuations. After issuing a high-temperature alarm, the
device does not issue another alarm if the temperature is in the range of (threshold – offset) °C to
threshold °C. The offset might be 3°C or 5°C, depending on the device model.
Follow these steps to configure temperature alarm thresholds for a member device:
•
To do...
Enter system view
Configure temperature alarm
thresholds for a member
device
Table 11 Default temperature alarm thresholds for a device
Device
S5120-28P-PWR-SI/
Use the command...
system-view
temperature-limit slot slot-number
hotspot sensor-number lowlimit
warninglimit [ alarmlimit ]
Sensor
1
133
Remarks
—
Optional
By default, the temperature alarm
thresholds follow the specifications listed
in Table 13.
The alarming threshold must be higher
than the warning threshold.
Warning limit
85
alarm, the temperature
Alarming limit
95