30 Pg Pulse Phase Check; Servo-Reference Delay Mv (Rec) - Sony AV-3600 Service Manual

Table of Contents

Advertisement

Interaction:
This
adjustment
may
interact
with those described
in Sections 6-5,
6-9,
and
6-11.
Whenever 30
PG
coil
A
is
adjusted, check
and,
if
necessary, readjust these
sections.
6-9.
30
PG PULSE PHASE CHECK
This
procedure
sets
up
the
precise
angular
dis-
placement between
the
two
30
PG
coils.
One
30
PG
coil
should
be
exactly
180°
from
the other.
When
properly
adjusted,
correct interlace
is
achieved
in
the
playback
picture
and
vertical
jitter
is
minimized. This
adjustment
follows
"30
PG
Pulse Position
Check"
in
Sec. 6-8.
CAUTION
Avoid adjustment
of the
30
PG
coil
unless
tests
indicate that the
adjustment
must
be
made.
Test Point/
Board:
TP-412/SV
(Shaped 30
PG
pulse out-
put)
Adjust
for:
Minimum
phase
difference
leading
edge
J
f
n
incorrect
overlap
^^^
trailing
edge
Fig. 6-9.
30
PG
Pulse
phase Check
Adjustment:
Signal Source:
Equipment
Required:
30
PG
Coil
B
Telecast Signal
(1)
Oscilloscope
(2)
TV
monitor
Procedure:
1
.
Set
up
the E-to-E
mode
using
a telecast
signal.
2.
Connect
the scope
to
TP-412.
3.
Sync
the scope
externally
from
TP-406.
Set the
time base
to
5
ms/cm.
4.
Turn
the
VARIABLE
control
of the
scopes
time-base
counterclockwise (from the
CALIB-
RATED
to
the
UNCALIBRATED)
until
two
pulses
can be
seen
at
the
same
time
on
the scope.
5.
Pull
out
the
5X
magnifier
and
adjust
the
HORI-
ZONTAL
POSITION
control
to
observe the
leading
edge of
either pulse.
See
Fig. 6-9.
6.
Check
that the leading
edge of
a
pulse
does not
overlap the
trailing
edge of the previous
pulse.
If
it
does
reposition
30
PG
coil
B
as
follows.
8.
Stop
the
motor
(release
the
RECORD
button).
Allow
the heads to stop
turning.
9.
Loosen
the screw securing
30
PG
coil
B,
which
is
mounted
at
the
rear
of the scanner,
at
the
12
o'clock
position.
See
Fig. 6-8.
10.
Move
30
PG
Coil
B
slightly
to the
left
or
right.
11. Start
the
motor
again
and check
the
waveform
in Fig. 6-9.
12.
Repeat
Steps 8 to
1 1
until
the correct
condition
is
obtained.
6-10.
SERVO-REFERENCE DELAY
MV
(REC)
The
servo-reference
delay multivibrator
(MM401)
adjusts
the
precise
angular position of
heads with
reference to the
vertical
sync
pulse.
Test
Point/
Board:
TP-403/SV
(Delayed
30
PG
pulse
output)
Adjust
for:
A
pulse
width
of
930
jusec.
See
Fig.
6-10.
TP-403
T
±
3
LI
6
±
1
V
•)
r
p—
scope
:
0.5
ms/cm
T=930jJs
Fig. 6-
10.
Delay
multivibrator
adjustmen
t
(REC
mode)
Adjustment/
Board:
R413/SV
(Lock
Phase)
6-6