Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HP Manuals
Measuring Instruments
3455A
Operating and service manual
HP 3455A Operating And Service Manual page 101
Digital voltmeter
Hide thumbs
Also See for 3455A
:
Operating and service manual
(219 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
page
of
249
Go
/
249
Bookmarks
Advertisement
Section
VIII
THEORY
OF OPERATION
Model
3455A
Figure 8-17.
Ohmt
Reference Meaiurement.
Notei:
VOLTAGE
LIMITED
TO
5
V.
FET
Switch
A10Q13. The
reference
is
measured
prior
to
8-16
illustrates
the
circuit
configuration
for
these
measure-
each
measurement of
the
unknown
resistance,
ments.
The
DC
Preamp
input
is
grounded through
a
100
kf2
resistor
by
FET
switch
A10Q2. The
feedback path
for the
8-41,
100
1
10
Mf2
Reference Measurements.
On
X2
gain
is
through
FET
switches
A10Q22
and
A10Q21.
the
100
kJ2
range,
AI0K7
is
opened and
the
.7
mA
current
Feedback
for
X20
gain
is
through
A10Q22,
isolation
amp-
source
is
applied
to the
combination of
R1
and
R5
(1
M£2).
lifier
AI0U3,
switch
A10Q27,
the precision
10-to-l divider
The
reference voltage
developed
across
R1 and R5
is
ap-
and
switch
A10Q18.
A
separate
measurement
is
made
for
plied
to
the
DC
Preamp
input
through
FET
switch
both
gains
and
the
results
are stored
by
the
main
controller.
A10Q14.
On
the
1
MJ2
and
lOMD
ranges, relay
A10K8
is
8-40.
.1
kSl,
1
kn.
10
kf2
Reference Measurements.
The
'^e
.7
M
current source
is
applied
to the
1
Mfi
ohms
reference voltage
is
developed
across the reference
reference
resistance.
The
reference voltage
is
applied
to
resistance.
On
the
.1
kfi
through 10
kfl ranges the
refer-
^
Preamp
input
through
A10Q14.
ence
resistance
is
I
kJ2
(see
Figure
8-17).
The
.7
mA
current source
is
connected
to the
I
kJ2 reference
through
8-42.
AUTO
CALIBRATION—
A/0
CONVERTER,
relay
A10K7. The 999
kfi reference
resistor
is
shorted
by
the
combination of
relay
AI0K7
and
AI0K8. The
refer-
8-43.
Two
Auto-Cal
measurements
are
made
to correct
ence
voltage
is
applied
to the
DC
Preamp
input
through
errors
which might
be generated
in
the
A/D
Converter.
One
Figure 8-18. Simplified
A/D
Converter Diagram.
8-10
Previous
Page
Next
Page
1
...
100
101
102
103
Advertisement
Related Manuals for HP 3455A
Measuring Instruments HP 3455A Operating And Service Manual
Digital voltmeter (219 pages)
Measuring Instruments HP 3458A Technical Manual
Digital voltmeter (43 pages)
Measuring Instruments HP 3456A Operating And Service Manual
Digital voltmeter (385 pages)
Measuring Instruments HP 3456A Operating And Service Manual
Digital voltmeter (315 pages)
Measuring Instruments HP 3400A Operating And Service Manual
Rms voltmeter (65 pages)
Measuring Instruments HP 3400A Operating And Service Manual
Rms voltmeter (81 pages)
Measuring Instruments HP 3400A Operating And Service Manual
Rms voltmeter (64 pages)
Measuring Instruments hp 3406A Operating And Service Manual
Broadband sampling voltmeter (88 pages)
Measuring Instruments HP 3437A Operating And Service Manual
System voltmeter (15 pages)
Measuring Instruments HP 3400B User's And Service Manual
Rms voltmeter (77 pages)
Measuring Instruments HP HP 37722A Technical Specifications
Telecom/datacom analyzers (8 pages)
Measuring Instruments HP 37718A Installation And Verification Manual
(202 pages)
Measuring Instruments HP 37718A Installation And Verification Manual
Communications performance analyzer (164 pages)
Measuring Instruments HP 3562A Service Manual
Dynamic signal analyzer (570 pages)
Measuring Instruments HP 333A Technical Manual
Distortion analyzer (53 pages)
Measuring Instruments HP 333A Operating And Service Manual
Distortion analyzer (20 pages)
Related Products for HP 3455A
HP 3456A
HP 3400A
hp 3406A
HP 3437A
HP 3400B
HP 3575A
HP 3561a
HP 3562A
HP 3585A
HP 333A
HP 334A
HP 37719A
HP Agilent 37717B PDH
HP Agilent 37717B SDH
HP 3580A
HP 3720A
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL