1.2.5 Environmental Conditions


Temperature

Operating : 50 to 95 °F (10 to 35 °C) (See Figure 1-8.)

Non-operating:-4 °F to 140 °F (-20 to 60 °C) in shipment
container
1 month at 104 °F (40 °C) and 120 hours at 140 °F (60 °C)
NOTE:

Humidity

Operating:
20% to 80% RH without condensation
(See Figure 1-8.)

Non-operating: 5% to 85% RH without condensation and in
shipping container
Figure 1-8. Temperature / Humidity of Range

Resistance to shock

Operating:
1 G, within 1 ms
X, Y, and Z directions

Non-operating: 2 G, within 2 ms
X, Y, and Z directions, in shipment container

Resistance to vibration

Operating:
0.15 G

Non-operating: 0.50 G
NOTES: 1. When the printer is not in operation, make sure that the
printhead is capped.
2. During transport, make sure the printhead is capped and
the ink cartridges are installed.
3. If you notice that the printhead is not capped while power
is off, turn power on (ink cartridges should be installed).
After the printhead has moved to the capping position,
turn power off again.
4. Ink freezes under 27 °F (-3 °C), but thaws and becomes
usable again after 3 hours at 77 °F (25 °C).