  • Page 1: Joint Angle Adapters

    Dial Up Adapter Model AW- Before attempting to connect, operate or adjust this product, please read these instructions completely.
  • Page 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
  • Page 3: Table Of Contents

    Contents Introduction ........3 Accessories ........3 Parts and their functions .
  • Page 4: Parts And Their Functions

    Parts and their functions $ Control panel 1 POWER indicator This lights when power is supplied to the main unit and the POWER switch is set to ON. 2 POWER switch This is the unit’s power switch. 3 LCD panel This displays the current statuses and menu settings.
  • Page 5: Rear Panel

    Parts and their functions $ Rear panel 6 RS-232C CONTROL OUT connectors (P1 to P5) These connectors are used to connect the pan-tilt head system controlled with RS-232C. <Note> These connectors cannot be used in conjunction with the RS-422 CONTROL OUT connectors 7. 7 RS-422 CONTROL OUT connectors (P1 to P5) These connectors are used to connect the pan-tilt head system controlled with RS-422.
  • Page 6: Connections

    Connections Turn off the power of all components before proceeding with the connections. Transmitting system connections Connect the control panel Control panel AW-PS301 OWhen an AW-RP301 or AW-RP501 is being used, connect the receiving pan-tilt head system to the P1 CONTROL OUT connector.
  • Page 7 Connections Transmitting system connection procedure Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. Set the control panel selector switch on this adapter. Set it to A when using an AW-RP605. Set it to B when using an AW-RP301, 501, 505, or WV- CB700A.
  • Page 8: Mounting Screws (M4)

    Connections Receiving system connections $ Connect the pan-tilt head system to the RS-232C CONTROL OUT connector: When an AW-PH300A is used and the connection distance is 10 m or less: Modem AW-DU600 When an AW-PH600 is used: Modem AW-DU600 G/L video (BNC cable) Video (BNC cable) COMPONENT <Note>...
  • Page 9 Connections Connect the pan-tilt head system to the RS-422 CONTROL OUT connector: Use the RS-422 connector when the AW-PH350 is to be used as the pan-tilt head or when the connection distance between this adapter and the pan-tilt head is to exceed 10 m. When an AW-PH350 is used: Modem AW-DU600...
  • Page 10 Connections When an AW-PH600 is used and the connection distance is more than 10 m: Modem AW-DU600 RS-232C/RS-422 10 Base-T converter cable AC adapter G/L video (BNC cable) Video (BNC cable) COMPONENT <Note> Refer to the Operating Instructions of the AW-PH600 for details on how to perform the connections for the AW-PH600.
  • Page 11 Connections Receiving system connection procedure Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. Connect the TO MODEM connector to the RS-232C connector on the modem using the RS-232C cable provided with the modem. Connect the telephone line to the line input jack on the modem.
  • Page 12: Making A Call

    Connections Making a call Make a call from the AW-DU600 of the transmitting system. Turn on the power to all units. Use the number keys on this adapter to enter the desired number. The telephone number entered appears on the top section of the LCD panel.
  • Page 13: Direct Mode

    Connections $ Direct mode Control the pan-tilt head system directly using this adapter: AW-DU600 AW-PS301 AW-CA50T29 (composite) AW-CA50C29 (component) Convertible camera 10 Base-T cable AW-PH350 AW-PS300...
  • Page 14: Aw-Du600

    Connections Connection procedure Connect the pan-tilt head system to the CONTROL OUT connector on this adapter. Turn on the power to this adapter and the pan-tilt head system. Dial Up Adapter settings 1 Set this adapter to direct mode. Press the key ( MENU+ the menu settings.
  • Page 15 Connections Control the pan-tilt head system using a control panel or PC: Coaxial cable (5C-2V) 10Base-T cable AW-PS301 AW-DU600 Control AW-CA50T29 panel Convertible camera AW-PH350 AW-PS301 10 Base-T cable AW-PS300 AW-CA50T9 AW-PS301 AW-DU600 AW-CA50T29 Convertible camera AW-PH350 10 Base-T cable AW-PS300 <Note>...
  • Page 16 Connections Connection procedure Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. Set the control panel selector switch on this adapter to 1 Connect the PAN/TILT CONTROL OUT connector on the control panel to the PAN/TILT CONTROL IN connector on this adapter using a 10 BASE-T (equivalent to UTP category 5) straight cable.
  • Page 17: Menu Settings

    Menu settings $ How to perform menu settings START STOP MENU MENU CLEAR RECALL TELE WIDE NEAR $ Menu items Dial up adapter mode settings Menu-1 Function (Initial setting: Tx) Direct The following items are only displayed when this adapter is in Tx mode. Telephone line settings Menu-2 Modulate Tone...
  • Page 18: Dial Memory

    Menu settings The following items are only displayed when this adapter is in Direct mode This setting selects which connector is to be used for the controller when this adapter is in Direct mode. Menu-4 Input RS-232C (Initial setting:RS-232C) RS-422 This setting selects which pan-tilt head system is to be controlled by this adapter when this adapter is in Direct mode.
  • Page 19: Rack Mounting Adapters

    Attaching the rack mounting adapters To install the adapter in a rack, use the rack mounting adapters and four of the mounting screws (M4) supplied. Changing the position of the rear panel 1. Remove the three screws from the bottom panel and remove the blank panel.
  • Page 20: Attaching The Joint Angle Adapter

    Attaching the joint angle adapter To attach the adapter to the controller, use the joint angle adapter, rack mounting adapter and mounting screws (M4 x 8) supplied. Screw Joint angle adapters Rack mounting adapter...
  • Page 21: Specifications

    Specifications Power supply: DC 10.8V to DC 16V Power consumption: 5 W indicates safety information Permissible temperatures Storage: j20˚C to 60˚C Operating: j10˚C to 45˚C Standard: i5˚C to 35˚C Permissible humidity Storage: 30% to 90% (without condensation) Weight: 3.7 lb (1.7 kg) Dimensions (WkHkD): 8-1/4k3-3/8k6-7/8 inch (210k86k176 mm) Controllers supported...
  • Page 24 PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7000 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835...