Evaporator Entering
Chiller
Water Temp Sensor
Evaporator Leaving
Chiller
Water Temp Sensor
Evaporator Entering
Chiller
Air Temp Sensor
Evaporator Leaving
Chiller
Air Temp Sensor
Condenser Entering
Chiller
Water Temp Sensor
Condenser Leaving
Chiller
Water Temp Sensor
Discharge Pressure
Circuit
Transducer
Suction Pressure
Circuit
Transducer
Suction Temperature
Circuit
Sensor
Low Evap Leaving
Chiller or
Water Temp: Unit Off
Circuit
Low Evap Leaving
Chiller or
Water Temp: Unit On
Circuit
Low Refrigerant
Circuit
Temperature
CG-SVU02E-GB
Diagnostics
Normal
Latch
Normal
Latch
Normal
Latch
Normal
Latch
Warning
Latch
Warning
Latch
Normal
Latch
Immediate
Latch
Immediate
Latch
Warning
NonLatch
Unit in Stop Mode,
and Special
or in Auto Mode
Action
and No Ckt(s)
Energized [Any Ckt
Immediate
NonLatch
and Special
Energized [No Ckt(s)
Action
Immediate
Latch
All except [Service
Pumpdown]
All
Bad Sensor or LLID
All
Bad Sensor or LLID
All
Bad Sensor or LLID.
All
Bad Sensor or LLID
All
Bad Sensor or LLID
All
Bad Sensor or LLID
All
Bad Sensor or LLID
All
Bad Sensor or LLID
All
Bad Sensor or LLID
a) The leaving chilled water temperature fell below the leaving
water temp cutout setting for 16.6°C- seconds while the
Chiller is in the Stop mode, or in Auto mode with no
compressors running. Energize Evap Water pump Relay
Energized]
until diagnostic auto resets, then return to normal evap
pump control. Automatic reset occurs when the temp rises
1.1°C above the cutout setting for 30 minutes. When this
diagnostic is active AND Leaving Water Temperature sensor
diagnostic (loss of comm or out of range) the Evap Water
pump relay shall be de-energized.
b) If evaporator protection temperature sensors are installed,
the effect is on the appropriate circuit. Else, the effect is on
the chiller.
Any Ckt[s]
a) The chilled water temperature fell below the cutout
setpoint for 16.6°C-seconds while a compressor was
Energizd]
running. Automatic reset occurs when the temperature
rises 1.1°C above the cutout setting for 2 minutes. This
diagnostic shall not de-energize the Evaporator Water Pump
Output. If this diagnostic is active the Low Evap Leaving
Water Temp: Unit Off diagnostic shall be suppressed.
b) If evaporator protection temperature sensors are installed,
the effect is on the appropriate circuit. Else, the effect is on
the chiller.
The Evaporator Saturated Refrigerant Temperature dropped
below the Low Refrigerant Temperature Cutout Setpoint for
16.6°C-seconds.