Table H-4: Is the External Health LED Green?
Answer
Possible Reasons
No, it is
One power supply has failed;
amber
therefore, power supply
redundancy is lost.
No, it is red
All installed power supplies have
experienced a failure.
Yes
Note: For cabling configurations, refer to Appendix D, "Cabling Guidelines." For LED locations and
functions, refer to Appendix E, "System LEDs and Switches."
H-8
Possible Solutions
Be sure that each installed power supply is
securely connected to an AC power source.
Locate the amber power supply LED to
identify the failed power supply.
Contact an authorized service provider for
replacement parts and service.
Remove all AC power from power supplies
and reconnect to clear the error condition.
Replace the power supply. Contact an
authorized service provider for replacement
parts and service.
Refer to Table H-5 if the external health LED
is green.