Table E-8: QuickFind Diagnostic Display LEDs
Item
Description
3
Processor
memory board
4
Processor
power module
5
Temperature
6
DIMM
7
I/O power fault
HP ProLiant DL585 Server User Guide
Status
Off = normal
On = attention required
Off = normal
On = attention required
Off = normal
On = attention required
Off = normal
On = attention required
Off = normal
On = attention required
System LEDs and Switches
continued
Action
Processor memory board power failure. If
problem persists, replace
processor/memory board.
PPM power failure. If problem persists,
replace PPM.
If the PPM and the BRD LEDs are both on,
there is a configuration error.
One or more components have
experienced an elevated temperature or a
thermal shutdown.
A thermal shutdown is indicated by the
Therm Trip LED.
Be sure the processor heatsink is
properly attached.
Be sure there are no 1.7" DIMMs
installed that prevent airflow across the
processor heatsink).
Be sure that all fans are installed and
working properly.
Be sure that the server environment
meets posted requirements.
For information about server environment
requirements refer to the "Optimum
Environment" section in Chapter 3.
DIMM failure or configuration error. Refer to
the IML or POST messages
A power fault on the system I/O board
occurred. If problem persists, replace the
system I/O board.
continued