Item
Model Name
Type
Ignition
Minimum Pressure for Maximum flow
Minimum Flow Rate
Dimensions
Weight
Water Holding Capacity
Connection Sizes
Power Supply
Materials
Safety Devices
Accessories
Item
Gas
Consumption (NET)
Hot Water Capacity
Capacity Range
Temperature Settings
Specifications
Installation
Air Supply/Exhaust
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Performance
1
2H
1
3P
25°C Rise
58°C Rise
Specification
WHX56
External, Wall Mounted
Power Vented
Direct Ignition
2.0 bar
2.5 L/min.
61.5 cm(Height) x 46.4 cm(Width) x 24 cm(Depth)
30 kg
1.1 Litre
3/4"
3/4"
3/4"
230V AC (50Hz)
83W
Freeze Prevention 115W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Pressure Relief Valve,
Lightning Protection Device (ZNR),
Electric Leakage Prevention Device, Overheat
Prevention Device, Freezing Prevention Device,
Fan Rotation Detector
Remote Controller, Anchoring Screws
Maximum Performance
62.3 kW
62.3 kW
32 L/min.
13 L/min.
2.5 - 32 L/min.
37 - 48, 50, 55, 60, 65, 70, 75, 80°C
LWHX56
Minimum Performance
5.0 kW
5.0 kW
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lwh42Lwh56Whx42Wh56Lwhx42Whx56 ... Show all

Table of Contents