4-6.

ZOOM BRUSH POSITION CHECK/ADJUSTMENT AND PATTERN CHECK

Note:
If dialog box of error code appears during the checking or adjustment, check the reason of error referring to page 4-22.
4-6-1. Zoom Brush Position Check
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Lens Adjustment Program
Note:
Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1) Connect the checking lens to the camera.
2) Start the lens adjustment program "LensAdjustment.exe" referring to "4-1-2. Lens Adjustment Program".
Fig. 4-6-1
2. Checking Method
[Connect]
1) Click the
button on the lens adjustment program.
[End]
Note:
Click the
Fig. 4-6-2
[Zoom]
2) Click the
button on the lens adjustment program.
3) Set the zoom position to Tele end, and check that the OK (Green) indicator of "Position" lights as shown in Fig. 4-6-3.
Note:
Lens focus position setting is not required.
Fig. 4-6-3
If the NG (Red) indicator of "Position" lights, check zoom brush and frekipattern is confirmed.
Fig. 4-6-4
[Exit]
4) Click the
button.
[End]
5) Click the
button to terminate the lens adjustment program.
6) Turn the POWER switch of the camera to OFF.
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
button to disconnect the USB connection, then lens adjustment program will terminate.
4-18