Table of Contents

Advertisement

Ver 1.3 2007.04
4-5.

LENS ROM CHECK

Note:
If dialog box of error code appears during the checking, check the reason of error referring to page 4-22.
Equipment
• Personal Computer (PC)
• Camera DSLR-A100
• USB Cord With Connector
• Lens Adjustment Program
Note: Lens Adjustment Program is downloadable from the ESI homepage.
1. Preparations
1)
Connect the checking lens to the camera.
2)
Start the lens adjustment program "LensAdjustment.exe" referring to "4-1-2. Lens Adjustment Program".
2. Checking Method
[Connect]
1)
Click the
Note:
Click the
2)
Check that the display of "Lens Code" and "Model Name" is correct.
Note:
Zoom and focus position setting is not required.
[End]
3)
Click the
4)
Turn the POWER switch of the camera to OFF.
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
Fig. 4-5-1
button on the lens adjustment program.
[End]
button to disconnect the USB connection, then lens adjustment program will terminate.
Fig. 4-5-2
button to terminate the lens adjustment program.
4-17