2. Focus-shift/Frange Back (f'F) Check and Optical Axis Adjustment
1)
Attach the checking lens to the flange back tester, and set the 1000 mm collimator.
1000 mmcollimater
2)
Set the focus ring of the checking lens to infinity end position while looking through the microscope, and align the optical axis to the
center of the chart image accurately.
3)
Turn the focusing knob of the tester until the chart image is the sharpest (red and green color areas are equal on the chart *).
*: Position in which the color of collimator chart changes from green into red and come into focus.
Also check the optical axis aligns with the chart center. (Refer to Fig.4-4-4.)
Note:
Figure shows example. The cause depends on individual lens.
Optical Alignment
Best alignment
4)
If the optical axis aligns the most unsharp, loosen the three screws shown in the Fig.4-4-5 and shift the 5th lens barrel assembly to let
the vertical and horizontal.
SAL1118 (4.5-5.6/11-18) (DT 11-18mm F4.5-5.6)
Checking lens
Fig.4-4-3
Incorrect aligned
e.g. As the focusing knob is turned, the chart may appear blurry as illustrated.
The cause depends on individual lens.
Screws
At the time of optical axis
(centering) adjustment
5th lens barrel
5th lens barre-B assembly
Fig.4-4-4
Fig.4-4-5
4-13
5th lens barre assembly
Screws
At the time of resolving
(partial blur) adjustment