Detailed descriptions
16.1 Motherboard
Assignment of the display to the display select pins
One of the 15 available displays is configured automatically via the display select inputs. The
display select inputs are connected to pull–up resistors, i.e. if these inputs are not
interconnected, they are high level. In order to create a low level input, the input must be
connected with GND.
Pin–No. LCD_SEL3
0
low
1
low
2
low
3
low
4
low
5
low
6
low
7
low
8
high
9
high
10
high
11
high
12
high
13
high
14
high
15
high
16-12
LCD_SEL2
LCD_SEL1
low
low
low
low
low
high
low
high
high
low
high
low
high
high
high
high
low
low
low
low
low
high
low
high
high
low
high
low
high
high
high
high
LCD_SEL0
Display type
low
reserved
high
1280x1024 (SXGA), TFT, 2 x 18Bit, LVDS-channel 1
and 2
low
DVI LCD 640 x 480
high
DVI LCD 800 x 600
low
640 x 480 (VGA), TFT, 18 Bit, LVDS-channel 1
high
reserved
low
1024 x 768 (XGA), TFT, 18 Bit, LVDS-channel 1
high
800 x 600 (SVGA), TFT, 18 Bit, LVDS-channel 1
low
reserved
high
reserved
low
reserved
high
reserved
low
1024 x 768 (XGA), TFT, 2 x 18-bit, LVDS channel 1
and 2
high
DVI LCD 1024 x 768
low
DVI LCD 1280 x 1024
high
No LVDS display or DVI LCD with automatic DDC ID