Technical Data

14.1
General Specifications
14.1
General technical data
Order numbers
Dimensions
Weight
Supply voltage (AC)
Supply voltage (DC)
Input current AC
Input current DC
Line voltage frequency
Transient current interruption according
to Namur
max. power consumption AC and DC
max. current output
Noise emission
Degree of protection
Safety
Protection class
Safety regulations
Electromagnetic compatibility (EMC)
Emitted interference
Noise immunity:
Mains borne disturbance variables on
supply lines
Noise immunity on signal lines
SIMATIC Box PC 627
Operating Instructions, Release 05/2006, A5E00362052-03
6ES7647-6Axxx-xxxx
Without DVD/CD-RW: 297x267x80 (WxHxD in mm)
With DVD/CD-RW: 297x267x100
approx. 7 kg
Nominal 100 - 240 V AC (-15% / +10%) (autorange)
Nominal 24 V DC (-15% / + 20%), SELV
Steady-state current up to 2.3 A (on start-up, up to 50A for
1 ms)
Continuous current to 9 A (to 14 A for 30 ms at startup)
50 - 60 Hz (47 to 63 Hz)
min.20 ms (at 93 to 264 V)
(max. 10 events per hour; min. recovery time 1 s)
190 W / 210 W
+5 V / 16.5 A
(18.5 W peak)
*
+3.3 V / 8.5 A
*
total of 90 W permitted
*
+12 V / 6.5 A (8 A peak)
–12 V / 0.3 A
The total sum of all voltages is max. 150 W.
< 55 dB(A) according to DIN 45635-1
IP 20
Protection class I to IEC 61140
AC: EN 60950-1; UL60950-1; CAN/CSA C22.2
No 60950-1-03
DC: EN 61131-2; UL508; CSA C22.2 No 142
EN 55022 Class B, EN 61000-3-2 Class D
EN 61000-3-3; FCC Class A
± 2 kV, (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge symm)
± 2 kV; (according to IEC 61000-4-5; Surge asymm)
± 1 kV;(according to IEC 61000-4-4; Burst; Length < 5 m)
± 2 kV; (according to IEC 61000-4-4; Burst; Length > 5 m)
± 2 kV; (according to IEC 61000-4-5; Surge; Length > 30m)