Electrical Connection; Connection; Power Cable - Bosch Therm 8000 S Installation And Operating Instructions Manual

Condensing gas water heater
Table of Contents

Advertisement

6.4.6 Exhaustion type C
Fig. 44
7

Electrical connection

DANGER: Risk of electric shock!
▶ Always disconnect the power supply to
the appliance at the mains before carrying
out any work on the electrical systems and
components.
All regulation, verification and safety mechanisms have been
rigorously tested in the factory and are ready for use.
CAUTION: Fuse protection!
▶ The appliance should have an
independent connection to the electricity
mains, protected by a differential 30 mA
switch and be earthed. In areas subject to
frequent storms, a storm protector
should be installed.
Therm 8000S
53
Ø 80 mm
Ø 135 mm est.
Ø 80 / 125 mm
Ø 80 mm
6720608920-29.1AL

7.1 Connection

The electrical connection should be
according to current regulations regarding
domestic electrical installations.
▶ An earth connection is absolutely
essential.
▶ Connect the feed cable to an earthed power point.

7.2 Power cable

The appliance is provided with a labelled power cord and
earthed mains plug.
If the power cable gets damaged it must be
replaced by a genuine spare part.
Electrical connection | 27
6 720 680 174 (2014/05)