In the example, rule mode shows the same situation as in
figure D: Three steel bars equally apart. In rule mode, the
clearance between the detected object centres can be deter-
mined.
The measuring distance covered from the starting point (in
the example 20.1 cm) is displayed under the indication of the
object depth l.
The three objects are displayed as rectangles in the small rule
above the operating-mode indication h.
Note: Both the indication of the object depth l as well as the
material property m refer to the object pictured black in the
sensor.
To return to the standard start display, briefly press selection
button 10 or 12.
Note: Only the display is reset, not the measuring mode!
"Settings" Menu
To access the "Settings" menu, press the setup button 14.
To exit the menu, press the start button 11. The current set-
tings are saved. The standard start display for the measuring
process is activated.
Navigating in the Menu
Press the setup button 14 to scroll down.
Press the selection buttons 10 and 12 to select the values:
– Selection button 10 will select the right-hand or next value.
– Selection button 12 will select the left-hand or previous
value.
Language
In the "Language" menu, you can change the menu-guidance
language. The default setting is "English".
Cut-off Time
In the "Cut- off time" menu, you can set certain time intervals
after which the measuring tool shall automatically shut off
when no measurements are taken or settings are carried out.
The default setting is "5 min".
Light Duration
In the "Display illum." menu, you can set a time interval, dur-
ing which the display 16 shall be illuminated. The default set-
ting is "30 sec".
Brightness
In the "Brightness" menu, you can set the brightness of the
display backlight. The default setting is "Max".
Tone Signals
In the "Tone signal" menu, you can limit when the measuring
tool shall give out an audio signal, provided that you have not
switched off the signal with the audio signal button 13.
– The default setting is "Wallobjects": An audio signal
sounds after each button press, and whenever a wall ob-
ject is under the sensor range. Additionally, a short-beat
warning signal is given for "live" wires.
– With the adjustment "Live wire", an audio signal sounds
after each button press, as does the warning signal for
"live" wires (short-beat signal) when the measuring tool in-
dicates a power line.
Bosch Power Tools
– With the adjustment "Keyclick", an audio signal only
sounds when pressing a button.
Default Mode
In the "Defaultmode" menu, you can set the default operat-
ing mode that is to be pre-set after switching the measuring
tool on. The operating mode "Concrete Universal" is the de-
fault setting.
"Extended Settings" Menu
To access the "Extended settings" menu, press the setup but-
ton 14 and the On/Off button 15 at the same time when the
measuring tool is switched off.
To exit the menu, press the start button 11. The standard
start display for the measuring process is activated and the
settings are saved.
Navigating in the Menu
Press the setup button 14 to scroll down.
Press the selection buttons 10 and 12 to select the values:
– Selection button 10 will select the right-hand or next value.
– Selection button 12 will select the left-hand or previous
value.
Device Information
In the "Device Info" menu, information on the measuring tool
is provided, e.g., about the "Operation Time".
In the "Restore Settings" menu, you can restore the factory
settings.
Examples for Measuring Results
Note: In the following examples, the audio signal on the mea-
suring tool is switched on.
Depending on the size and depth of the object under the sen-
sor range, it is not always possible to positively determine
whether this object is "live" or voltage-free. In this case, the
?
symbol will appear in indicator n.
"Live" Wire (see figure C)
A "live", metal object (e. g. a power cable) is within the sensor
range. The object depth is 1.5 cm. The measuring tool emits
the warning signal for "live" conductors as soon as the power
cable is detected by the sensor.
Steel Bar (see figure D)
A magnetic object (e.g. a steel bar) is within the sensor range.
Further objects are also located to the left and right, outside
of the sensor range. The object depth is 5.5 cm. The measur-
ing tool emits an audio signal.
Copper Pipe (see figure E)
A metal object (e. g. a copper pipe) is within the sensor range.
The object depth is 4 cm. The measuring tool emits an audio
signal.
Plastic or Wooden Object (see figure F)
A non-metal object is within the sensor range. The object is
plastic or wooden, and close to the surface. The measuring
tool emits an audio signal.