KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF CONTENTS 1 BATTERY 1.1. Recharge 1.2. Battery information 2 BATTERY REPLACEMENT 3 LOCATION OF CONTROLS 3.1. Base Unit 3.2. Handset 4 CONNECTION 4.1. Adding Another Phone 5 OPERATIONS 5.1. Making Calls 5.2.
Page 3
20.3. Modification Procedure of Bridge 21 CABINET AND ELECTRICAL PARTS LOCATION (BASE UNIT) 22 CABINET AND ELECTRICAL PARTS LOCATION (HANDET) 51 KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 23 ACCESSORIES AND PACKING MATERIALS 24 REPLACEMENT PARTS LIST 24.1. Base Unit 24.2.
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 4 CONNECTION USE ONLY WITH Panasonic AC ADAPTOR PQLV16CEZ. The AC adaptor must remain connected at all times. (It is normal for the adaptor to feel warm during use.) When more than one unit is used, the units may interfere with each other. To prevent or reduce interference, please leave...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 4.1. Adding Another Phone This unit will not function during a power failue. To connect a standard telephone on the same line, use a telephone T-adaptor.
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 7.2. Bell Reception Cross Reference: Check Link (P.20) Telephone Line Interface (P.41) Cross Reference: Check Link (P.20) *: Each measurement points are shown in CIRCUIT BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset) (P.67)
The operation-flow of Test mode and main check items are shown below. Note: **: Refer to the above table. Symptom KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Remedy* Make adjustments in item (A) Make adjustments in item (B)
8.4. Adjustment Standard (Base Unit) DC12V or AC adaptor AF OSC Loop SIMULATOR AF Volt Meter (F) Note: (A) - (H) is refered to ADJUSTMENTS (BASE UNIT) (P.23) FM Deviation Audio Meter Analyzer Confirmation of VCO voltage Frequency Counter Volt Meter RX-VCO TX-VCO TXPOWER...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 9 ADJUSTMENTS (HANDSET) If your unit have below symptoms, adjust or confirm each item using remedy column from the table. The movement of Battery Low Indicator is wrong. The base unit does not respond to a call from the handset.
1. Apply a MIC signal (1KHz, 2.4mV at 600 2. Confirm so that the reading FM Deviation Meter is 3.1KHz ± 0.4KHz. Confirm so that the reading of the FM Deviation Meter is 5kHz ± 1kHz. KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Check or Replace...
9.4. Adjustment Standard (Handset) (Component View) AF Volt Meter (H) Note: (A) - (I) is refered to ADJUSTMENTS (HANDSET) (P.26) (A) Battery Low Oscilloscope (G) Noise Squelch 47 F Generator...
Page 29
(Flow Solder Side View) 43.820MHz RF Millivolt Meter Frequency Counter Audio (I), (J) FM Deviation Analyzer Meter TX VCO DC Volt Meter RX VCO DC Volt Meter Note: (A) - (I) is refered to ADJUSTMENTS (HANDSET) (P.26) Volt Meter TXGND TXPOWER DC Power Supply...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 10 RF SPECIFICATION 10.1. Base Unit Item TX Frequency TX Power Line Modulation factor Line Modulation factor (Max.) Data Modulation factor Line Output level *: Refer to Adjustment (P.24). 10.2. Handset...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 13 EXPLANATION OF CPU DATA COMMUNICATION 13.1. STAND-BY -> TALK, TALK -> STAND-BY *: The channel is changed if the noise interferes with the conversation.
The DATA which is transmitted from the Base Unit to the Handset is combination of DATA 0, DATA 1, PSEUD. 13.5.1. Handset 13.5.2. Base Unit For example (one of part of data) KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Base Unit: transmitting (TX) ... 17 Pin receiving (RX) ... 10 Pin...
D2, D3, ·• LINE D4, D5 Q11, IC3 SEIZURE POWER SUPPLY RESET CHARGE DC IN 12V 150mA REGULATOR (AC Adaptor) Q18, Q19 AC DOWN RESET CHARGE CONTROL Q14, Q17 DC 12V CHARGE CHARGE TERMINAL KX-TC1205RUB/W/S/F BLOCK DIAGRAM (BASE UNIT) TEL LINE...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 16 CIRCUIT OPERATION 16.1. Outline Base unit consists of the following ICs as shown in BLOCK DIAGRAM. CPU:IC2 Controlling the whole system Forming/analyzing all data signals (ACK, CMD signal etc.*) All interfaces (ex: LED, KEY, SP, Mic, LCD, Detector Circuit (Charge/ Power Down) *Refer to EXPLANATION OF CPU DATA COMMUNICATION (P.32).
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 16.2. Power Supply Circuit The power supply to the CPU (Digital, Analog) and RF IC from AC Adaptor (+12V) is shown in the diagram below. The base unit power supply is DC12V. The handset´s power is supplied from 3.6V battery (Nickel-Cadmium battery) which is installed in the handset.
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 16.3. Reset Circuit (Base Unit) After power supply from AC adaptor, the VREG is input for making reset signal. Refer to the below waveform. Fig. 2 Fig. 3...
Basically this circuit prevents the TX signal from feeding back to RX signal. As for this unit, TX signal feed back from Q11 is canceled by the cancellor circuit of AGC. [CHG+(Handset) R148 R116 R161 R [OFF HOOK] KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF BATT(1)...Battery...BATT(2) IC2 (24) [BELL]...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 16.6. Transmitter/Receiver Base Unit and Handset are mainly consists of RF(Radio Frequency) IC and CPU. Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency.
VC1 is the reference frequency for adjustment. The 10.7 MHz is mixed with reference and 450KHz narrow band IF is generated. The demodulation audio signal is adjusted to the maximum at T1. RF IC is controlled by CPU (RF_STB, DATA, CLK). The RX local frequency is generated by RXVCO. KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF...
The power of handset is supplied by battery. Whenever the battery is recharged or inserted, the impulse at CHG+ becomes Reset signal through Q11, and sent to CPU. KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Fig. 4 Fig. 5...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 17.2. Battery Low / Power Down Detector Circuit Operation: “Battery Low” and “Power Down” are detected by RF IC which check the voltage from battery. Shortly, every detected blocks are inside of RF IC. The detected voltage is as follows;...
2. Apply flux for all pins of FLAT PACKAGE IC. 3. Solder employing specified solder to direction of arrow, as sliding the soldering iron. KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF 20.3. Modification Procedure of Bridge 1. Re-solder slightly on bridged portion.
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Ref. Part No. Part Name & Description C129 ECUV1C104ZFV C130 ECEA1AKA101 C131 ECUV1C104KBV C132 ECUV1C104KBV C133 ECUV1H390JCV 24.2. Handset 24.2.1. CABINET AND ELECTRICAL PARTS Ref. Part No. Part Name & Description...
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF Ref. Part No. Part Name & Description R102 ECUV1H333KBV 0.033 24.3. ACCESSORIES AND PACKING MATERIALS Ref. Part No. Part Name & Description PQJA10075Z TEL CORD PQLV16CEZ AC ADAPTOR PQQX13178Z INSTRUCTION BOOK...
1. DC voltage measurements are taken with an oscilloscope or a tester with a ground. 2. The schematic diagrams and circuit board may be modified at any time with the development of new technology. mark have special characteristics important for safety. When replacing KX-TC1205RUB / KX-TC1205R UW / KX-TC1205R US / KX-TC1205RUF...