Download Print this page

Advertisement

Quick Links

Models:
DV338***
DV339*** DV407***
DV409*** DV419***
DV438*** DV448***
Display
do
FE
dF
hE or HE
bE
IMPORTANT SAFETY NOTICE – "For Technicians Only" This service data sheet is
intended for use by persons having electrical, electronic, and mechanical experience
and knowledge at a level generally considered acceptable in the appliance repair trade.
Any attempt to repair a major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible, nor assume any liability for
injury or damage of any kind arising from the use of this data sheet.
Samsung 'Dryer' Diagnostic Code Quick Guide
Description
Dryer Thermistor Short
Sensed
Dryer Thermistor Open
Sensed
Door Open
Power source frequency
Error
Door Circuit Failure
Heater Error
Button Error
Fast Track Troubleshooting
Publication # tsDV407 Creation Date 1/22/2010
Trigger
The Thermistor resistance is
very low.
The Thermistor resistance is
very high.
Running the dryer with door
open
Invalid power source Frequency Check for: Non Utility power supply
Invalid state for more than 256
milliseconds
Invalid heating Temp in running
the dryer
PCB key closed for 75 sec.
Action Taken
Check for: Clogged lint screen,
Restricted vent system, Thermistor
resistance.
Check for: Clogged lint screen,
Restricted vent system, Thermistor
resistance.
Check for: Loose or open wire
terminals in Door Sense circuit.
Check for: Loose or open wire
terminals in Door Sense circuit.
Check for: Restricted vent system,
Thermistor resistance.
Check Display PCB for stuck button
1

Advertisement

loading

Summary of Contents for Samsung DV339 series

  • Page 1 The manufacturer or seller cannot be responsible, nor assume any liability for injury or damage of any kind arising from the use of this data sheet. DV438*** DV448*** Publication # tsDV407 Creation Date 1/22/2010 Samsung 'Dryer' Diagnostic Code Quick Guide Display Description Trigger...
  • Page 4 1Water Valve (Blk) 3-6 Thermistor (Blu-Red) CN2 Sub PCB Display 2 Door Sw (Blu) 4-5 Moisture Sensor (Pnk-Org) 1 120vac N (Brn) 2 Sub PCB (Wht) 3 Sub PCB (Yel) Relay 1 1 Motor Belt Sw (Brn) 2 120vac L1 (Blk) 1 Earth Ground (Grn) Relay 6...
  • Page 5: Door Switch

    Thermistor Dryer continues to run after cycle completed Temp F Ω Wrinkle Prevent option provides approximately 90 minutes of intermittent tumbling 20KΩ in unheated air at the end of the cycle to reduce wrinkling. Press the Wrinkle Prevent button to activate this feature. 15.8KΩ...
  • Page 6 Testing Steam Cycle: Select Wrinkle Care cycle for 4 minutes, check for heat and moisture. If both are present, the dryer is working properly Time and Control Temp. Cooling 1st Heating Resign 1 Spray Resign 2nd Heating Resign 2nd Spray Resign 3rd Heating Resign resign time...

This manual is also suitable for: