Honeywell KMH 880 Installation Manual page 190

Bendix/king multi-hazard awareness traffic advisory system
Hide thumbs Also See for KMH 880:
Table of Contents

Advertisement

B
Verify that the "TAS" flag appears on the traffic display.
Reset the circuit breaker. Verify that the flag clears.
Pass/Fail _____
2.
On the TAS Control Panel exercise all the TAS control functions
and observe for correct operation.
Test the ON/OFF and STB/ON functions as follows:
Set the PWR switch to the OFF condition. (If applicable)
Reset the PWR switch to the ON condition. (If applicable)
Set the SBY switch to the ON mode.
On the traffic display screen, check that "TA" or "TA ONLY" annuncia-
tion is displayed.
Pass/Fail _____
Test the ABOVE/NORMAL/BELOW function as follows:
On the TAS Control Panel, set the ABOVE/NORMAL/BELOW
to ABOVE. On the traffic display screen, "ABOVE" should be
annunciated. Traffic between 2700 feet below and 8700 feet
above can be displayed.
Select BELOW. The screen should annunciate "BELOW" in
place of the "ABOVE" annunciation. Traffic between 8700
feet below and 2700 feet above can be displayed.
Set the switch to NORMAL. The screen area that annunciated
"ABOVE" or "BELOW" should be blank. Traffic between
2700 feet above and 2700 feet below can be displayed.
Traffic Display _____
On the traffic display, check the TAS ranges to observe the range
annunciations and range rings.
The following ranges are available for the KMH 820/KTA 810: 2, 2.5, 5, 7, 10,
15, 20 and 40 nm.
Rev 3, August/2002
NOTE
10609I03.CDL
KMH 880/KTA 870
Page 4-26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kta 870

Table of Contents