Table 6. DS4800 Storage Subsystem weights (continued)
Unit
1
battery module weighs 1.1 kg (2.5 lb).
2
3
material.
Table 7. DS4800 Storage Subsystem component weights
Unit
RAID controller
Power supply-fan
Interconnect-battery unit
Battery module
Shipping dimensions
Table 8 lists shipping carton dimensions. The height shown includes the height of
the pallet.
Table 8. DS4800 Storage Subsystem shipping carton dimensions
Height
44.4 cm (17.5 in.)
Environmental requirements and specifications
This section describes the environmental conditions that are prerequisite to
installing the unit, and heat and sound conditions that are generated by normal
operation of the unit.
Temperature and humidity
Table 9 lists the acceptable temperature and humidity ranges in which the storage
subsystem is designed to operate.
Important: The recommended operating environment air temperature is 22° C (72°
Table 9. Temperature and humidity requirements
Condition
Temperature
20
IBM System Storage DS4800 Storage Subsystem: Installation, User's, and Maintenance Guide
Weight
Maximum
Maximum weight indicates a storage subsystem with two battery modules installed. Each
Empty weight indicates a storage subsystem with all components removed.
Shipping weight indicates the maximum weight of the storage subsystem and all shipping
F) or lower.
1
1
2
Empty
Weight
6.36 kg (14 lb)
3.72 kg (8.2 lb)
5.36 kg (11.8 lb)
1.134 kg (2.5 lb)
Width
62.2 cm (24.5 in.)
Parameter
Operating range
Maximum rate of change
Storage range
Maximum rate of change
Transit range
Maximum rate of change
3
Shipping
Depth
78.7 cm (31.0 in.)
Requirement
10° - 35° C (50° - 95° F)
10° C (18° F) per hour
1° - 60° C (33° - 140° F)
15° C (27° F) per hour
-40° C to 65° C (-40° F to
149° F)
20° C (36° F) per hour