8.2 Spin part
Check if the capacitor
is good?
NO
Replace the capacitor.
Check if the spin timer
is opened ?
Check if the power source
is available?
Check if the contact between
the plug and receptacle is good?
Check if the power supply
cord is good?
Check if the inlay of
the connecting wire
terminal is good?
Check if the fuse is good?
YES
Check if the micro-switch is closed?
Check if the motor is good
Check if the brake system
is detached?
Repair the brake system.
YES
YES
YES
YES
YES
YES
YES
YES
NO
13
Issue
Rev.
NO
Open the spin timer.
NO
Switch on the power.
NO
Replace the plug
or receptacle.
NO
Replace with new
power supply cord.
NO
Inlay the connecting
wire again.
NO
Replace the fuse.
NO
Repair the micro-switch,
make it closed.
NO
Replace the motor.

Hide quick links: