45º Stop (Fig. K-1)
1. Turn the blade tilting handwheel until the blade tilting
scale is 45°.
2. Turn the blade elevation handwheel and raise the
blade to the maximum elevation.
3. Place a combination square on the table and against
the blade to check if the blade is 45° to the table.
4. If the blade is not 45° to the table. Remove the back
cover (2) of the base by removing the screw (1),
three for each side.
5. Adjust the bevel tilting handwheel to make an
adequate distance between the anchor block (3) and
bevel gear (4).
6. Loosen the two set screws (5) of the anchor block (3)
with 3mm allen key.
7. Separate the anchor block (3) from the worm (6).
• When the bevel angle is more than 45°, turn the
anchor block (3) to A direction in adequate degree
until the bevel angle and bevel scale is the same.
• When the bevel angle is less than 45°, turn the
anchor block to B direction in adequate degree
until the bevel angle and bevel scale is the same.
8. When completing the above adjustment, replace the
set screws (5) and tighten them.
9. Replace the back cover (2) and then tighten the
screws (1), three for each side.
Fig. K-1
4
BLADE TILTING INDICATOR (FIG. L)
1. When the blade is positioned at 90º, adjust the blade
tilt pointer to read 0º on the scale.
2. Remove the magnifier, position the pointer over 0º
and replace the magnifier.
NOTE: Make a trial cut on scrap wood before making
critical cuts. Measure for accuracy.
Fig. L
B A
3
5
6
INSTALLING THE TABLE INSERT (FIG. N)
The table insert has been previously installed on your
unit. However, you must verify that the table insert is
flush with the table top surface on all four corners of the
insert.
If the table insert is not flush with the table, adjust the
four screws (1) with a screwdriver until it is parallel
with the table.
NOTE: To raise the insert, turn the hex screws
counterclockwise, to lower the insert, turn the hex
screws clockwise.
Fig. N
STORAGE (FIG. O, P)
Rip fence and miter gauge (Fig. O)
Storage brackets for the rip fence (2) and miter gauge
(1) are located on the right side of the saw housing and
frame of leg.