Replace Imaging Unit Or Imaging Unit Is Near End Of Life - Xerox phaser 6250 Service Manual

Hide thumbs Also See for phaser 6250:
Table of Contents

Advertisement

Replace Imaging Unit or
Imaging Unit is Near End of Life
Print the Supplies Usage page and verify life remaining and date Imaging
Unit was installed.
Cycle printer power.
If the problem persists, follow the procedure below
Note
The "Imaging Unit is Near End of Life" is a warning. "Replace Imaging Unit" is
a hard stop.
Troubleshooting Reference Table
Applicable Parts
Imaging Unit PL 9.1.3
Troubleshooting Procedure Table
Steps
Actions and Questions
1
Check the following parts for evidence of
fault or damage:
Imaging Unit PL 9.1.3
CRUM Connector on the Plate Dispenser
2
Replace the Imaging Unit .
Does the error recur?
3
Verify the CRUM Harness is properly
connected.
See "Laser Unit" on page 10-22.
4
Check CRUM Harness Assembly for
continuity.
See "Laser Unit" on page 10-22.
5
Check the EEPROM Harness for
continuity.
See "Fuser Assembly" on page 10-21.
3-38
Wiring and Plug/Jack Map References
"Laser Unit" on page 10-22
Phaser 6250 Color Laser Printer Service Manual
Yes
Replace the parts
concerned.
Go to Step 3.
Go to Step 4.
Go to Step. 5.
Replace the
Engine Control
Board,
page 8-107.
No
Go to Step 2.
Complete
Replace the
CRUM Harness
Assembly,
PL 10.1.15.
Replace the
CRUM Harness
Assembly,
PL 10.1.15.
Replace EEPROM
Harness
Assembly,
PL 13.1.10.