Download  Print this page

Freezer Cut-in/out Temperature Differential - Viking VCSB542 Service Manual

Built-in side-by-side refrigerator/freezer.
Hide thumbs

Advertisement

Diagnostics
Mode A Functions (continued)
The indicator light and corresponding differential temperatures are listed below.
Indicator
Cut-In/Out
Temperature Differential
*Default setting

Freezer Cut-In/Out Temperature Differential

Note: Settings should not be changed unless instructed or if they are not correct.
The parameter defines the temperature separation between the freezer cut-in and cut-out temperatures.
Place the unit in Program Mode A (see Program Mode on page 22). Press the "MAx Frz" pad. An audio
confirmation beep will be heard. The Max Frz indicator will be illuminated. The differential temperature will
be displayed by use of one of the nine temperature indicator bars. The 9th bar is the default setting for the
freezer compartment.
The differential temperature is changed by using the raise Temp and Lower Temp keys. Pressing the "rAISe
TeMP" key once will change the temperature by one level; pressing the "LOwer TeMP" key once will change
the temperature by one level in the opposite direction.
The indicator light and corresponding differential temperatures are listed below.
Indicator
Cut-In/Out
Temperature Differential
*Example shown above
© 2010 Viking Preferred Service
1
2
3
3
5
5
1
2
3
3
4
5
4
5
6
6
7
8
4
5
6
6
7
9
7
8
9
9
10
12*
7
8
9
11*
13
15
26