HP MSR SERIES Configuration Manual page 399

Hide thumbs Also See for MSR SERIES:
Table of Contents

Advertisement

Figure 385 Setting up a GRE tunnel
4.
Configure a static route from Router B through interface Tunnel 0 to Group 1:
a.
Select Advanced > Route Setup from the navigation tree.
b.
Click the Create tab and then perform the configurations shown in
c.
Enter 10.1.1.0 as the destination IP address.
d.
Enter the mask length 24.
e.
Select the box before Interface, and then select egress interface Tunnel0.
f.
Click Apply.
Figure 386 Adding a static route from Router B through interface Tunnel 0 to Group 1
Verifying the configuration
On Router B, ping the IP address of Ethernet 0/0 of Router A:
1.
Select Other > Diagnostic Tools from the navigation tree of Router B.
2.
Click the Ping tab.
3.
Enter the destination IP address 10.1.1.1.
4.
Click Start.
5.
View the result of the ping operation in the Summary area.
382
Figure
386.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents