INSTALLATION INSTRUCTIONS
Downdraft unit internal blower electrical connection
Connect black (L1/live) wire from the power
supply cable into the right terminal Fig.26.
Connect the green (ground) wire from the power
supply cable into the middle terminal Fig.26.
Connect the white (neutral) wire from the power
supply cable into the left terminal Fig.26.
Ensure that the terminal screws are tightly
holding all wires in place.
Replace the cover of the terminal box Fig.25.
Fig.26
Downdraft unit remote blower electrical connection
Connect the power supply cable into the box as described in the 'Downdraft unit
internal blower electrical connection' section (above).
To use a remote blower, install a control cable between the downdraft unit and
the remote blower. See the 'Remote blower electrical connection' on next page.
Additional knock outs should be used for the remote blower wiring.
Install a suitable UL listed strain relief or conduit fitting (not included) into the
knock out.
Connect the remote blower wiring into the downdraft unit: N (neutral) into the
right terminal, L1 (live) into the left terminal and the green (ground) wire goes
into the ground terminal Fig.27.
Ensure that the terminal screws are tightly holding all wires in place.
The remote blower will be connected to the additional control cable
Replace the cover of the terminal box Fig.25.
Remote blower
control cable
Home power
supply cable
Downdraft
wiring
Fig.27
Fig.25
Home power
supply cable
Downdraft
wiring